Multilink OPTILINK BMS Installation And Operation Manual

Multilink OPTILINK BMS Installation And Operation Manual

Serial-to-ethernet bms monitoring module

Advertisement

Quick Links

OPTILINK BMS
Serial-to-Ethernet BMS Monitoring Module
Installation and Operations Manual
Documented Models
The following Optilink BMS models are documented by this instruction and operations manual.
MODEL
PART NUMBERS
OPTIONS
OPTILINK BMS
740-095-20
See Specifications

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OPTILINK BMS and is the answer not in the manual?

Questions and answers

Summary of Contents for Multilink OPTILINK BMS

  • Page 1 OPTILINK BMS Serial-to-Ethernet BMS Monitoring Module Installation and Operations Manual Documented Models The following Optilink BMS models are documented by this instruction and operations manual. MODEL PART NUMBERS OPTIONS OPTILINK BMS 740-095-20 See Specifications...
  • Page 2 Multilink Inc. 580 Ternes Ln. | Elyria, OH 44035 | 440.366.6966 | www.gomultilink.com © Multilink Inc. 2023 • All Rights Reserved...
  • Page 3: Table Of Contents

    User Login: ..................................10 SNMP Configuration:................................. 10 Network Configuration: ..............................11 Troubleshooting: ..............................12 Optilink BMS Specifications: ............................. 13 Multilink Inc. 580 Ternes Ln. | Elyria, OH 44035 | 440.366.6966 | www.gomultilink.com © Multilink Inc. 2023 • All Rights Reserved...
  • Page 4: Introduction And Operation

    Ethernet connection, either through SNMP or the embedded webpage. From the factory, the Optilink BMS is configured with a static IP address. This allows users to directly connect to the unit to configure the device for a different static IP address or configure the device for DHCP to automatically receive an IP address.
  • Page 5: Connections, Controls, And Indicators

    ON: device alarm, serial comm. error OFF: no alarm ON: serial comm. is active COMM OFF: serial comm. is not active Multilink Inc. 580 Ternes Ln. | Elyria, OH 44035 | 440.366.6966 | www.gomultilink.com © Multilink Inc. 2023 • All Rights Reserved...
  • Page 6: Installation

    Installation: Prior to beginning installation, please verify the Optilink BMS and its harnesses are not damaged. NOTE: The serial cable provided uses RJ45 connectors, similar to a standard Ethernet cable. DO NOT attempt to connect the serial cable to the Ethernet port or an Ethernet cable to the serial port.
  • Page 7: Snmp Operation And Configuration

    Webpage Use and Navigation: Embedded in each Optilink BMS is a standalone web server that contains a webpage to allow for both local and remote observation and configuration. The embedded webpage is addressable by entering the assigned IP address into a web browser.
  • Page 8: Summary Page

    Summary Page: The Optilink BMS Summary Page provides the user with all pertinent information for the respective battery. On the page, a menu list with several selectable options heads the top of the page. Selecting any one of these tabs displays a submenu the user may then select to view.
  • Page 9: Device Config - Optilink Bms Page

    Device Config - Optilink BMS Page: This page provides network parameters, device information, and current configuration for the Optilink BMS device. By default, several of the items are pre-configured at the factory. Those items are not user configurable, and a red caution symbol will display when navigating over these items.
  • Page 10: User Login

    Should the user modify any available option, be sure to click the Submit button to save changes. Click Cancel to reject any modifications. Multilink Inc. 580 Ternes Ln. | Elyria, OH 44035 | 440.366.6966 | www.gomultilink.com © Multilink Inc. 2023 • All Rights Reserved...
  • Page 11: Network Configuration

    The user may also enter an NTP address and select the time zone. Should the user modify any available option, be sure to click the Submit button to save changes. Click Cancel to reject any modifications. Multilink Inc. 580 Ternes Ln. | Elyria, OH 44035 | 440.366.6966 | www.gomultilink.com © Multilink Inc. 2023 • All Rights Reserved...
  • Page 12: Troubleshooting

    • Verify the correct SNMP protocol is in use. By default, the Optilink ST uses SNMPv2. Multilink Inc. 580 Ternes Ln. | Elyria, OH 44035 | 440.366.6966 | www.gomultilink.com © Multilink Inc. 2023 • All Rights Reserved...
  • Page 13: Optilink Bms Specifications

    Elevation Up to 3000m Agency Approval FCC Part B Sub 15 Standards and HTTPS, TCP/IP, UDP, SNMP, SNTP Protocols Multilink Inc. 580 Ternes Ln. | Elyria, OH 44035 | 440.366.6966 | www.gomultilink.com © Multilink Inc. 2023 • All Rights Reserved...
  • Page 14 Fax: +1 440 366 6802 Fax: +1 440 366 6802 Mobile: +1 440 366 6802 Email: engsupport@gomultilink.com Email: engsupport@gomultilink.com Email: lasupport@gomultilink.com Multilink Inc. 580 Ternes Ln. | Elyria, OH 44035 | 440.366.6966 | www.gomultilink.com © Multilink Inc. 2023 • All Rights Reserved...

This manual is also suitable for:

740-095-20