Summary of Contents for Ijinus Overflow
Page 1
Sensors Dataloggers Web services Overflow detector quick start guide PL00202-01B1 du 04/03/2024...
Page 2
The overflow detector can be set to trigger the overflow state after a certain number of measurements exceeding a predefined threshold (time delay), so for a measurement every 4 seconds and a time delay of 4 the detector will trigger after 4x4=16 seconds.
Page 3
Sensors Dataloggers Web services The V4 detector contains a battery that allows the product to measure and record data when not connected to a power supply, and to be paired via BLE with a smartphone running the dedicated App. Enable Bluetooth and localisation: for connectivity between the phone and the detector to be usable, the distance between the 2 products in open field (i.e.
Page 4
Depending on the type of PLC, it may be necessary to polarise the input - refer to the PLC documentation. It is recommended that the overflow detector be powered from a voltage source between 9 and 26 V. Power is supplied via the green wire (V+) and the brown wire (V- / Common).