Download Print this page

ipf electronic OH700371 Manual

Frame light barrier

Advertisement

Quick Links

OH700371
Frame light barrier
I
integrated pulse extension
I
PNP switching output
I
Normally open contact / normally closed
contact switchable
I
M8-connector
Static and dynamic
Operating principle
TECHNICAL DATA
Active zone
Resolution
Output signal
Operating voltage
Current consumption (without load)
Output current (max. load)
Voltage drop (max. load)
Transmitting element (clocked)
Wavelength
Response / release time
Display (signal)
Setting (sensitivity)
Setting (time)
Setting
Short circuit proof
Reverse polarity protected
Dimensions
Material (housing)
Material (Optics)
Temperature (operation)
Protection class (EN 60529)
Connection
Connection accessories
Connection
ipf electronic gmbh │ Rosmarter Allee 14 • 58762 Altena • Germany │ Tel +49 2351 9365-0 • info@ipf-electronic.com •
MANUAL • Subject to alteration! Version: June 2022
70 x 68mm
dynamic Ø 1.5mm / static Ø 2mm
pnp, no/nc
10 ... 35V DC
50mA
200mA
1.2V
LED infrared
940nm
0.1ms / 0 ... 150ms
LED yellow
potentiometer
potentiometer 0 ... 150ms
change-over switch stat./dyn. und no/nc
+
+
118 x 110 x 20mm
aluminum, black anodized
polycarbonate
-20 ... +55°C
IP67
M8-connector, 3-pin
e.g. VK200075
www.ipf-electronic.com
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the OH700371 and is the answer not in the manual?

Questions and answers

Summary of Contents for ipf electronic OH700371

  • Page 1 Temperature (operation) -20 … +55°C Protection class (EN 60529) IP67 Connection M8-connector, 3-pin Connection accessories e.g. VK200075 Connection www.ipf-electronic.com ipf electronic gmbh │ Rosmarter Allee 14 • 58762 Altena • Germany │ Tel +49 2351 9365-0 • info@ipf-electronic.com •...
  • Page 2 The machine must be secured against restarting. www.ipf-electronic.com ipf electronic gmbh │ Rosmarter Allee 14 • 58762 Altena • Germany │ Tel +49 2351 9365-0 • info@ipf-electronic.com •...
  • Page 3 "NO-NC" rotary switch, the switching output is active when the LED is on, in the "NC" position, the switching output is inactive when the LED is on. www.ipf-electronic.com ipf electronic gmbh │ Rosmarter Allee 14 • 58762 Altena • Germany │ Tel +49 2351 9365-0 • info@ipf-electronic.com •...
  • Page 4 At the end of its service life, the product must be disposed of at a suitable disposal point for the recycling of electrical and electronic equipment in accordance with the country- specific regulations (WEEE-Nr. 40951076). www.ipf-electronic.com ipf electronic gmbh │ Rosmarter Allee 14 • 58762 Altena • Germany │ Tel +49 2351 9365-0 • info@ipf-electronic.com •...