Page 1
Installation and maintenance manual This product is not suitable for primary heating purposes Serial number: Production date:...
Page 2
Barbas Bellfires BV. This document could contain technical inaccuracies or typographical errors. Barbas Bellfires BV reserves the right to revise this document from time to time in the contents thereof.
Contents Contents Declaration of Performance..............5 55............................. 5 55 with wood log storage module..................6 55 with support frame.......................7 About this document................8 How to work with this document....................8 Warnings and cautions used in this document................8 Related documentation........................ 8 Description....................
Page 4
Contents Installation of the BOX 55 with wood log storage module....28 Install the appliance ........................28 Connect the optional external air supply..................29 9.2.1 Rear connection......................29 9.2.2 Bottom connection......................30 Connect the flue gas pipe......................30 Final check on the appliance..................... 30 Installation of the BOX 55 with support frame........31 10.1...
Name, registered trade name or registered trade mark Barbas Bellfires BV; Hallenstraat 17; 5531 AB Bladel; The Netherlands and contact address of the manufacturer as required pursuant to Article 11(5)
Name, registered trade name or registered trade mark Barbas Bellfires BV; Hallenstraat 17; 5531 AB Bladel; The Netherlands and contact address of the manufacturer as required pursuant to Article 11(5)
Name, registered trade name or registered trade mark Barbas Bellfires BV; Hallenstraat 17; 5531 AB Bladel; The Netherlands and contact address of the manufacturer as required pursuant to Article 11(5)
About this document About this document This document shows the necessary information to do these tasks on the BOX • Installation • Maintenance This document refers to the BOX 55 as 'the appliance'. This document is an essential part of your appliance. Read it carefully before you do work on the appliance. Keep it in a safe place.
Description Description Note: The appliance is a room-sealed appliance only if combustion air comes from the outer side of the building through a pipe that is connected to the combustion air inlet of the appliance. In all other cases the appliance is not a room-sealed appliance and the data for leak tightness as given in section are not valid.
Description Overview of the bottom of the appliance Airwash inlet Upper baffle Heat shield Connection for external combustion Lower baffle with secondary air inlet air supply openings BOX 25 55...
Appliance options Option Description A stone base under the appliance as alternative for the steel base. Barbas does not supply the stone base, but Stone base the installer can order a stone base according the specifi- 13.4 cations in section at a local supplier.
Page 15
Description The appliance is intended for intermittent use and is not intended for continuous use. The appliance is intended to heat the room by direct heating. It is not allowed to connect the appliance to a central-heating installation. BOX 25 55...
Safety Safety Safety instructions for installation Warning: • Installation must be done by a qualified installer. • Install the appliance in accordance with the following installation instructions and the national and local applicable regulations. • Make sure that the area around the fireplace is free of flammable material at all times.
Clearances Clearances Warning: • Obey the instructions in this section. Failure to follow these instruction can create a fire hazard. • Do not put the appliance directly against a flammable or non-flammable wall. Caution: Make sure that flammable materials near the appliance can never reach a temperature above 85 degrees centigrade •...
Page 18
Clearances Minimum distance to Minimum distance to Label flammable materials in Remark non-flammable mate- rials in cm See remark. Install a non-flammable floor plate with not applicable a thickness of minimum 5 cm (floor stone) when the appliance is put on a flammable floor.The width (E) of the floor plate must be minimum 15 cm from each side of the appliance.
Clearances Safety distances BOX 55 with wood log storage module 55 with wood log storage module Minimum dis- Minimum dis- tance to flamma- tance to nonflam- Label Remark ble materials in mable materials in cm Install a non-flammable floor plate (floor stone) in not applicable front of the appliance when put on a flammable floor.
Page 20
Clearances 55 with support frame Minimum distance Minimum distance to Label to flammable mate- Remark nonflammable materi- rials in cm als in cm Not applicable Do not install on a flammable wall. Not applicable Install a non-flammable floor plate (floor stone) when the appliance is put above a flammable floor.
Page 21
Clearances Example for the graph: If the bottom of the 55 with support frame is 25 cm above the floor (vertical axis on the graph), the depth of the non-flammable floor in front of the appliance (horizontal axis on the graph) is minimum 35 cm. BOX 25 55...
Installation requirements Installation requirements Requirements on the installation of the appliance • Make sure that the location agrees with the safety requirements. Refer to section • Make sure the floor is made of concrete or a solid pedestal of non-combustible material.
Page 23
Installation requirements • Do not use horizontal flue pipes. • The chimney outlet must be minimum 6 meter above the top of the appliance. • The chimney outlet must be minimum 40 cm above the top of a sloped roof. •...
Installation of the BOX25 55 with steel base Installation of the BOX 55 with steel base Install the appliance Put the appliance in the designated position. To put the appliance on a natural stone platform, refer to section Obey the safety distances. Refer to section If necessary, put a nonflammable hearth under the appliance.
Installation of the BOX25 55 with steel base Remove the round break out plate with a hammer. Put the collar adaptor in the open external air inlet opening. Bend out the 3 lips on the collar adaptor to attach the collar adaptor on the inlet opening.
Installation of the BOX25 55 with steel base Connect the flue gas pipe Caution: During operation of the appliance the outer side of the flue system becomes hot. Refer to section for minimum distances to flammable material. Note: If the appliance is installed on an unlined, masonry flue with a large diameter, consider using a flue lining system to improve the performance of the appliance.
Installation of the BOX25 55 with stone base Installation of the BOX 55 with stone base Put the stone base on the intended location of the appliance. Obey the safety distances. Refer to section Put the appliance on the stone base.
Installation of the BOX25 55 with wood log storage module Installation of the BOX 55 with wood log storage module Install the appliance Put the appliance in the designated position. Obey the safety distances. Refer to section If necessary, put a nonflammable plate under the appliance. Refer to section Make sure that the flue connection on the appliance is correct in line with the flue pipe to the ceiling.
Installation of the BOX25 55 with wood log storage module Connect the optional external air supply • The appliance has the possibility to connect a supply pipe for external combustion air. During operation the appliance gets combustion air from this air duct.
Installation of the BOX25 55 with wood log storage module 9.2.2 Bottom connection Remove the round break out plate at the bottom of the appliance with a hammer. If necessary, put the collar adaptor in the open external air inlet opening.
Installation of the BOX25 55 with support frame Installation of the BOX 55 with support frame 10.1 Install the appliance 55 with support frame Use the steel template to mark the locations on the wall for the 4 corner screws by which the support frame is attached to the wall and to mark the location for the external air supply.
Installation of the BOX25 55 with support frame Attach the heat shield (A) to the support frame (B). Use an 11 mm fork spanner. Remove the baffles, bottom plates, grate and the door of the appliance to decrease the weight of the appliance.
Installation of the BOX25 55 with support frame Remove the round break out plate at the rear of the appliance with a hammer. Another round break out plate is now visible. Remove the round break out plate with a hammer.
Installation of the BOX25 55 with support frame Make sure that all mechanical connections of the flue system are correctly used. Make sure that all of the flue system is gas-tight, 10.4 Final check on the appliance Make sure the door closes and opens easy.
Clean the inside of the appliance with a soft brush. Clean the metal parts on the outside of the appliance with a dry lint free cloth. Use Barbas heat resistant paint spray to repair lacquer damage. 11.2 Combustion air supply Make sure that the inlet of the pipe of the external combustion air supply is not blocked by leaves or other debris.
Maintenance Lift the front log guard (1) and move the left side up. Remove the front log guard (2) Lift the 2 grate plates and remove from the combustion chamber. Move the 2 steel bottom plates to the center of the fireplace bottom. Lift the steel bottom plates up and remove.
Maintenance 11.5.1 Remove the heat shield Open the door. Loosen the nut above the heat shield with a 3 mm hexagonal key and a 10 mm fork spanner. Turn the nut down with the fork spanner and turn the screw up with the hexagonal key until the screw is loose from the heat shield.
Maintenance Move the upper baffle approximately 1 cm forward (1) Push up the right side of the upper baffle a small distance (2). Lower the left side of the upper baffle a small distance (3) and remove the baffle from the appliance (4). 11.6 Install the bottom plates, ash tray and grate Put the left steel bottom plate on the...
Maintenance Put the front log guard on the notches. 11.7 Installation of the baffles 11.7.1 Install the upper baffle. Refer to section 11.7.2 Install the lower baffle. Refer to section 11.7.3 Install the heat shield. Refer to section 11.7.1 Install the upper baffle Move the upper baffle under an angle into the combustion chamber.
Maintenance Push the baffle rearward until the 2 cams on the rear of the baffle go into the notches. The cam is in the notch if the baffle cannot move to the left or the right. 11.7.2 Install the lower baffle 11.7.1 Only do this procedure after finish of the procedure in section Move the lower baffle up under an...
Maintenance Make sure the upper baffle (2) is still in the correct position. If the upper baffle is not in the correct position, remove the lower baffle (1) and put the upper baffle in the correct position and install the lower baffle again.
Technical data Technical data 12.1 Technical data Name Barbas • Model • 55 with wood log storage module • 55 with support frame EPREL registration number 1938280 EN 13240:2001-A2:2004 EN16510-1 annex D, E, F Tested in accordance with BS 3841-2:1994...
Page 43
Technical data Minimum distance to flammable mate- rials • side wall • back wall • floor Refer to section • ceiling Used materials • Combustion chamber back and Vermiculite 750 kg/m / Heat resistant ceramic 1600 side panels kg/m / cast iron **) •...
Technical data 12.2 Product information according regulation (EU) 2015/1185 Model identifier BOX25 55 Equivalent models BOX25 55 with wood log storage module; BOX25 55 with support frame Indirect heating function Direct heat output 8.8 kW Indirect heat output - kW...
Dimensions 13.2 Dimensions BOX 55 with wood log storage module *) Combustion air inlet openings (Ø 125 mm) at the rear side and bottom of the appliance. 13.3 Dimensions BOX 55 with support frame *) Combustion air inlet openings (Ø 125 mm) at the rear side and bottom of the appliance. BOX 25 55...
Warranty Terms Warranty Terms To make a claim under the warranty, it is important to register the Barbas appliance after pur- chase via www.barbasbellfires.com. Barbas Bellfires Warranty Terms Barbas Bellfires B.V. guarantees the quality of the supplied Barbas appliance and the quality of the materials used.
Page 50
Article 5: Warranty period This warranty will only be granted during the warranty period. The body of the Barbas appliance is guaranteed for a period of 10 years against construction and/or material faults, starting from the moment of purchase. For other parts of the Barbas appliance, a similar warranty applies from the moment of purchase for a period of two years.