Download Print this page

Advertisement

Quick Links

EZYTAP Range
Installation and Operating Instructions
Installation and Operating Instructions
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the EZYTAP Series and is the answer not in the manual?

Questions and answers

Summary of Contents for AAFIRST EZYTAP Series

  • Page 1 EZYTAP Range Installation and Operating Instructions Installation and Operating Instructions...
  • Page 2 EZYTAP Range Breakdown Installation and Operating Instructions...
  • Page 3: Read These Warnings First

    Read These Warnings First Please read all installation requirements, installation procedures • and precautions before installing the EZYTAP water boiler. • Never attempt to install any water dispenser without reading all of the applicable instructions. All electrical connections must comply with current wiring rules. •...
  • Page 4 EZYTAP75/75T Voltage AC 220V, 50Hz (Tap Shown as Example Is EZ001T Taller Tap) Water Pressure Max 50 PSI Tank Capacity 4.2 Litres Power 2000 Watts Mains Water Supply to Boiler Un-Chilled Water Outlet To Tap Cold In Hot Water Outlet to Tap EZYTAP75/75T EZYTAP7800/7800T Voltage...
  • Page 5 Filter Configuration for Hard & Soft Water EZYTAP 7800/7800T/8800/8800T (Boiler, Chiller, and Tap) EZYTAP In Soft Water Area EZYTAP In Hard Water Area EZYTAP 75/75T/85/85T (Boiler and Tap Only) EZYTAP In Hard Water Area Installation and Operating Instructions...
  • Page 6 EZYTAP 75(T)/7800(T) Installation Instructions & Tips 1. Determine a convenient location to mount the EZYTAP faucet on your worktop. This can be an existing faucet hole, or you may need to drill a new 30/35mm hole into your worktop. If installing with the EZYTRAY refer to the instructions provided with the EZYTRAY.
  • Page 7 EZYTAP 75(T)/7800(T) Installation Instructions & Tips The tap rotates 30 degrees each side. You can stop it rotating. 1. Rotate tap fully to one side. 2. Carefully remove grub screw at rear of tap. 3. Rotate tap a little further round and screw in grub screw. 4.
  • Page 8 De-scaling the 75/7800 Boiler • Scale is a major problem for Hot Water Tanks in Hard Water areas. A build-up of scale inside the tank can seriously affect the safety and the performance of the equipment. The parameters affecting the formation of scale are. •...
  • Page 9 The EZYTAP85/8800 has a large 8 Liter boiler which supplies 28ltr/hour of 95C+ per hour of boiling water, with an instant draw off of 7 Liters. The 8 Liter boiler is different in design to the 4 Liter boiler of the Ezytap75/7800 range. This has implications for installation and servicing.
  • Page 10 Vent Connected to Tap Hot Water Outlet to Tap Cold Water Supply Inlet Cold Water Outlet to Tap Cold Water Supply to Boiler Vent Connected to Tap Hot Water Outlet to Tap Cold Water Supply Inlet Cold Water Outlet to Tap Cold Water Supply to Boiler Installation and Operating Instructions...
  • Page 11 EZYTAP 85(T)/8800(T) Installation Instructions & Tips 1. Determine a convenient location to mount the EZYTAP faucet on your worktop. This can be an existing faucet hole, or you may need to drill a new 30/35mm hole into your worktop. If installing with the EZYTRAY refer to the instructions provided with the EZYTRAY.
  • Page 12 EZYTAP 85(T)/8800(T) Installation Instructions & Tips The tap rotates 30 degrees each side. You can stop it rotating. 1. Rotate tap fully to one side. 2. Carefully remove grub screw at rear of tap. 3. Rotate tap a little further round and screw in grub screw. 4.
  • Page 13 De-scaling the 85(T)/8800(T) Boiler • Scale is a major problem for Hot Water Tanks in Hard Water areas. A build-up of scale inside the tank can seriously affect the safety and the performance of the equipment. The parameters affecting the formation of scale are. •...
  • Page 14 Error codes 85(T)/8800(T) Distributed by: Cedar House Grange Farm Long Lane Newbury RG14 2TF TEL: 44 (0) 01635 202489 FAX:44 (0) 01635 202499 E-Mail: enquiries@aafirst.co.uk http://www.aafirst.co.uk Installation and Operating Instructions...