Advertisement

Quick Links

TM
HEAT
PUMP
For Domestic Hot
Water
Model range:
airtherm AQUA 1.1 200L
airtherm AQUA 1.1 260L
airtherm AQUA 1.1 200L w/solar
airtherm AQUA 1.1 260L w/solar
User manual
ENG
Brook House, Dunmurry Industrial Estate, Dunmurry, Belfast, Co. Antrim, BT17 9HU
T: 028 9061 6505 M: hello@brookvent.co.uk brookvent.co.uk

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the airtherm AQUA 1.1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for BrookVent airtherm AQUA 1.1

  • Page 1 Model range: airtherm AQUA 1.1 200L airtherm AQUA 1.1 260L airtherm AQUA 1.1 200L w/solar airtherm AQUA 1.1 260L w/solar User manual Brook House, Dunmurry Industrial Estate, Dunmurry, Belfast, Co. Antrim, BT17 9HU T: 028 9061 6505 M: hello@brookvent.co.uk brookvent.co.uk...
  • Page 2: Dear Customer

    Thank you for choosing this product! BROOKVENT has always paid a great deal of attention to environmental problems, therefore, we have used technologies and materials with a low environmental impact to manufacture products in conformity with RAEE – ROHS (2002/95/CE and 2003/108/CE) community standards.
  • Page 3: Before Starting The Unit

    1. BEFORE STARTING THE UNIT! • Read carefully the “Installation and maintenance manual”, that is an integral part of your appliance! • Check if the unit is installed and connected according to the “Installation and maintenance manual”, that is an integral part of your appliance! •...
  • Page 4: Using The Device

    3. USING THE DEVICE 3.1. Switching ‘ON’ When connecting the appliance to the main power supply, all icons are displayed on the controller screen for 3 seconds. After that an initial check will start. If everything is ok, the unit enters into a standby mode: Standby mode: 3.2.
  • Page 5 3.4. Setting desired water temperature When the unit is working, press or button to adjust the set temperature of water tank. The maximum achievable water temperature by heat pump only, depends on outside air inlet temperature and could be seen on the graph below: If the temperature set on the control display is more than achievable one indicated in the graph above, the E-heater will be switched ON automatically to reach it.
  • Page 6 4. FLEXIBLE USAGE OF YOUR APPLIANCE! 4.1. Timer setting  After switching the appliance on, press and hold button for 5 seconds to enter the timer setting interface, the timer on icon and hour icon “88:” will flash together;  Press the and buttons to set the exact hour(s). ...
  • Page 7: Fan Ventilation

    6.3. Pump anti-block function: When the external pump (if any) stops for 12 hours, it will be forced to run for 2 minutes. 6.4. Fan ventilation The icon indicates that the fan ventilation function is enabled. When the heat pump is ON, press this button and hold for 5 seconds to enable or disable the fan ventilation function.
  • Page 8 7.1. Possible errors/explanation Error Code Wskaźnik LED Stand by Standard operation LED on (glows red) Lower tank water temp sensor failure  (1 flash) Upper tank water temp sensor failure (2 flashes) Coil temp sensor failure (3 flashes) Air return temp sensor failure (4 flashes) Ambient temp sensor failure (5 flashes)
  • Page 9: Environmental Guidelines

    Environmental Guidelines This symbol on the product(s) and / or accompanying documents means that used electrical and electronic equipment (WEEE) should not be mixed with general household waste. For proper treatment, recovery and recycling, please take this product(s) to designated collection points where it will be accepted free of charge. health and the environment, which could otherwise arise from inappropriate waste handling.