Rainwater underground tank

Advertisement

Quick Links

Installation and maintenance instructions for
Li-Lo XL/XXL Rainwater Underground Tank
DN 110:
7500 L
Order No. 390828
10000 L
Order No. 390822
15000 L
Order No. 390823
20000 L
Order No. 391810
25000 L
Order No. 391811
The points described in these
instructions must be observed
under all circumstances. All
warranty rights are invalidated in
the event of non-observance.
Separate installation instructions
are enclosed in the transportation
packaging for all additional articles
purchased from GARANTIA.
Missing instructions must be
requested from us immediately.
The tank must be checked for any
damage prior to insertion into the
trench under all circumstances.
Missing instructions can be
downloaded on
https://www.GARANTIA.com/en-
au/
or can be requested from
GARANTIA.

Table of contents

1.
1.1
2.
3.
3.1
3.2
4.
5.
5.1
5.2
5.3
5.4
6.
6.1
6.2
6.3
6.4
6.5
7.
7.1
8.
1 / 11
2
2
3
4
4
4
5
5
6
6
8
8
9
9
9
9
10
10
10
10
11

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Li-Lo XL and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Garantia Li-Lo XL

  • Page 1: Table Of Contents

    Installation and maintenance instructions for Li-Lo XL/XXL Rainwater Underground Tank DN 110: 7500 L Order No. 390828 10000 L Order No. 390822 15000 L Order No. 390823 20000 L Order No. 391810 25000 L Order No. 391811 Table of contents...
  • Page 2: General Notes

    QMS:ISO 9001:2015 certified. GARANTIA offers a wide range of accessory parts which are precisely coordinated and can be used to complete systems. The use of different accessory parts can lead to impact the functionality of the system, and to void liability for consequential damages.
  • Page 3: Installation Conditions

    Installation conditions Possible coverage heights from cutting dome shaft. 585/1035 mm In areas with pedestrian loads only (class A installations), extension riser may be used for a maximum coverage height of 1500mm. In areas driven by vehicles up to 3.5 tonnes (class B installations), cover heights may be from 750mm to 1300mm.
  • Page 4: Technical Data

    Technical data Overview connection option DN 110 Overview tanks Li-Lo XL Tank 7500 L 10000 L 15000 L Art. No. Weight 390 kg 460 kg 710 kg 3600 mm 4900 mm 7500 mm 2250 mm 2250 mm 2250 mm 1250 mm...
  • Page 5: Tank Structure

    Li-Lo XL tank  Installation and assembly   Subsoil Covering layer   GARANTIA Cover Li-Lo XL Rainwater Underground Tank   Compacted foundation Concrete layer for passable surfaces  Surrounding (round-grained gravel, max. grain size 8/16) 5 / 11...
  • Page 6: Construction Site

    Installation and assembly (continuation) Construction site Under all circumstances, the following points must be clarified prior to installation: The structural suitability of the ground • • Maximum groundwater levels which occur and drainage capability of the subsoil • Types of loads which occur An expert ground report should be requested from the local planning authority to determine the physical characteristics of the subsoil.
  • Page 7 5.2.5 Connection of several tanks Two or more tanks are connected via the assembly 600 min surfaces by means of GARANTIA special seals. The apertures must be drilled to the corresponding size using GARANTIA special crown bit. It must be ensured that the distance between the tanks is at least 600 mm. The pipes must project at least 200 mm into the tanks.
  • Page 8: Insertion And Filling

    Installation and assembly Insertion and filling The tanks must be inserted, impact-free, into the prepared trench using suitable equipment. To avoid deformities, the tank is filled 1/3 with water before filling in the tank surrounding. Afterwards the surrounding (round gravel, max.
  • Page 9: Assembling The Tank Dome Telescopic Dome Shaft

    Assembling the tank dome telescopic dome shaft Assembling the tank   Prior assembly, the enclosed seal is locked onto the tank neck’s  profile "B". The tank dome is then locked to the tank neck. It is essential to make sure that the upper seal "A"...
  • Page 10: Assembly Of Car Module (Class B)

    (can be inclined by 5°)   Profile seal   Li-Lo extension riser   Profile seal   Li-Lo XL dome (can be rotated by 360°)  Li-Lo XL adaptor   Tank seal  10 / 11...
  • Page 11: Inspection And Servicing

    Inspection and servicing The entire system must be checked for leaks, cleanliness and stability at least every three months. The entire system should be serviced at intervals of approx. 5 years. In this case, all parts of the system must be cleaned and their function checked. Servicing should be carried out as follows: •...