Pixel controlled module 16 x tri-9w cob leds (15 pages)
Summary of Contents for Ampro NEO 380 IP
Page 1
NEO 380 IP OUTDOOR BEAM MOVING HEAD USER MANUAL | MANUAL DE USUARIO PLEASE READ THE INSTRUCTIONS CAREFULLY BEFORE USE POR FAVOR LEA LAS INSTRUCCIONES ANTES DE USAR P. 1 Versión Español | Tecshow NEBULA PAR 162 II...
OUTDOOR BEAM MOVING HEAD asynchronous8-facet rotating prism. PHILIPS MSD PLATINUM FLEX 300S LAMP • 8-facet linear prism NEO 380 IP is an outdoor beam moving head powered • Gobo Shake by a Philips MSD Platinum Flex 300S lamp. The units •...
• Do not stick filters or other materials onto the lens. supply. • Certified safety cables must always be used when installing the fixture. P. 3 English Version | NEO 380 IP...
3. FIXTURE OVERVIEW 3.1 DIMENSION 400 mm 439.5 mm 280 mm 344 mm 344 mm 472.46 mm 270º 270º 270º P. 4 English Version | NEO 380 IP...
Page 5
BASE MODULE 3.3 ACCESORIES ITEM UNIT REMARKS USER MANUAL CLAMPS Hanging integrated folding lamp, Load weight 200KG SAFETY CABLE Φ5*60cm 7*19 pc with hook Material Steel 3-PINS SIGNAL LINE POWER CABLE 1.5*1.5mm2 P. 5 English Version | NEO 380 IP...
3. Flight case: Wrap the fixture in plastic bags. Hold it carefully put it inside the cardboard box. by the handles, and then carefully place it inside the flight case along with all the accessories. Close the P. 6 English Version | NEO 380 IP...
3. Check if pan and tilt are unlocked before fixture. Horizontally insert the clamp into the connecting the unit to AC power. mounting holes of the chassis. CLAMP CLAMP SAFETY CABLE MOUNTING POSITION P. 7 English Version | NEO 380 IP...
Page 8
2. TO AVOID ANY IMPACT ON THE BEAM, DO NOT TOUCH THE BULB WITH YOUR BARE HANDS. THE LAMP MUST BE KEPT CLEAN WITH THE USE OF THE CLEAN PAPER CONTAINED IN ITS PACKAGE. P. 8 English Version | NEO 380 IP...
DMX TERMINATOR OUTPUT OUTPUT OUTPUT INPUT INPUT INPUT 6.3 TESTING Connect the fixture to AC power. Check if the lamp is on and the fixture is independently controllable before putting into operation. P. 9 English Version | NEO 380 IP...
• or exit. corresponding sub menu. Each menu represents a specific function of the fixture. 8. TECHNICAL SPECIFICATION 8.1 PHOTOMETRIC NEO 380 ILLUMINANCE (LUX) 107530 11948 6721 4301 26883 2° Distance(m) Diameter(m/ft.) P. 10 English Version | NEO 380 IP...
4: Yellow 5: Purplish Red 6: Light Yellow 7: Blue Green 8: Green 9: Rose Red 10: Lavander 11: Flourescence 12: Claybank 13: Brown 14: Cool White ROTATING COLOR WHEEL FIXED GOBO WHEEL P. 11 English Version | NEO 380 IP...
Pan And Tilt Motor Reset Color Reset Color Motor Reset Motor Reset Gobo Reset Gobo Motor Reset Strobe Reset Strobe Motor Reset Other Reset Other Motor Reset P. 12 P. 12 English Version | NEO 380 IP English Version | NEO 371 3IN1...
Page 13
Edit the scene time Get scene DMX form console Auto-Program10 Step 8=Scene xxx Start Scene: XX Record Scene Scene XX Record scene form console End Scene: XX *Settings hightlighted in light grey are default values. P. 13 English Version | NEO 380 IP...
Color 12 40.78% 43.53% Color 13 43.92% 49.80% Color 14 Color continous rotation CCW from 50.20% 73.33% slow to fast. 73.73% 76.47% Stop Color continous rotation CCW from 76.86% 100% slow to fast. P. 14 English Version | NEO 380 IP...
Page 15
76.86% 100% CCW from slow to fast. Dimmer 0.0% 100% From 0% to 100% Dimmer 16 Bit 0.0% 100% Dimmer, fine tuning 25.5% 27.8% Prism 1 28.2% 30.6% 33.3% Prism 2 100% P. 15 English Version | NEO 380 IP...
Page 16
Bult-in program 5 62.7% 66.3% Bult-in program 6 66.7% 70.2% Bult-in program 7 70.6% 74.1% Bult-in program 8 74.5% Bult-in program 9 78.4% 82.0% Bult-in program 10 82.4% 85.9% Reserved 86.3% 100% No Function P. 16 English Version | NEO 380 IP...
Check if the switching power supply has No DC voltage from switching power DC voltage output. Replace the switching supply. power supply. P. 19 English Version | NEO 380 IP...
Page 20
Thermostat damaged. Replace. P. 20 English Version | NEO 380 IP...
Page 21
Non-clear shape manual to clean the focus module or module or objective lens. objective lens. Damaged or deformed focus module or Replace the damaged or deformed focus objective lens. module or objective lens. P. 21 English Version | NEO 380 IP...