This publication Tel +44 (0)1422 842159 is for International usage. Alpha is a trademark of Calrec Audio Ltd. All other Fax +44 (0)1422 845244 trade marks acknowledged. Email Enquiries@calrec.com Calrec Audio Ltd reserve the right to change specifications without notice.
(Reduction of Hazardous Substances) legislation, from the second week in April If in doubt, please contact Calrec Audio 2006 the vast majority of Calrec PCB and Limited for guidance prior to commencing cable assemblies will have been produced any such work.
The maximum potential between the terminals exceeds 60 volts, the blanking plates are fitted to avoid the risk of electric shock. CALREC Putting Sound in the Picture...
Hebden Bridge request. HX7 8EZ England Repairs If you need to return goods to Calrec, for whatever reason, please contact the Tel: +44 (0) 1422 842159 Company beforehand in order that you Fax: +44 (0) 1422 845244 can receive advice on the best method Email: support@calrec.com...
**Wide Area Bulk Cards are used to expand the I/O of the system via a wide area interface such as MADI, or Hydra - Calrec’s Hydra I/O units can interface up to 96 inputs sophisticated audio HYDRA I/O UNIT and 96 outputs, analogue or digital. These networking system.
Up to 5 Analogue I/O Racks 1 Bulk I/O card to interface to the Digital I/O Rack Up to 8 mic/line or line input cards, in line with the quotation Up to 8 line output cards, in line with the quotation 10 ALPHA with Bluefin...
Non-operating: -20°C to +60°C (-4°F to suitable fixings during transit to prevent +140°F). movement, and possible damage. Calrec Audio Ltd is not liable for any damages to Relative humidity the touch screen, the touch screen arm, Operating: 25% to 80% non condensing.
These allow being mono in which case the two halves ports to be used for different purposes of the pair have separate labels and the & suffixes are not applied. Note that I/O marked in this way 12 ALPHA with Bluefin...
Analogue output for 0dBFS matches input setting into >1kOhms (+24dBu max into 600 Ohms) The system can be pre-set with up to five external sync sources, plus internal, such that if the 1st source fails, it will automatically switch to the 2nd, and so on. CALREC Putting Sound in the Picture...
TFT METER TFT METER TFT METER TFT METER custom frames, with wedge sections etc, METER please contact Calrec. DELAY AUX O/P MON SEL MON LS The smallest frame size is 12 modules wide, made up of 3 sections (4:4:4) and usually provides 32 faders with two audio paths on each fader.
(shaded) for access to premises. The control surface sections can also be split apart if required. OB Frame Dimensions When housed in an outside broadcast vehicle, the rack equipment is located underneath the console. CALREC Putting Sound in the Picture...
Analogue I/O Rack Multi-Rail PSU 33.0 10.0 **** Multi-Rail PSU Other Multi-Rail PSU For longer distances, custom MADI Unit Digital I/O Rack 16.5 made cables can be provided. Hydra Gigabit Interface Unit Digital I/O Rack 16.5 20 ALPHA with Bluefin...
Broadcast Facilities panel would begin to bay. In outside broadcast situations, the flash and a message would be sent to the unit should ideally be located into an control surface via AWACS. equipment bay which offers mechanical support from underneath. 22 ALPHA with Bluefin...
A Gigabit Ethernet port is provided to but cannot change PC hardware settings of the side brackets, each of which enable the PC to be connected to a Calrec (i.e. set up network, install drivers. It is has two mounting holes. The PC rack...
(such as saving even if not edited). If the file needs to be e-mailed to Calrec for any reason it should always be zipped to protect the file time/date stamp. A new backup copy of this file should be made after a console upgrade.
Video, (PAL or NTSC). TTL Wordclock is another possible external source. Video and TTL Wordclock Synchronisation Two Video (PAL or NTSC) and two TTL Word Clock synchronisation inputs are provided on the rear of the Digital CALREC Putting Sound in the Picture...
The Serial Port Settings screen is used to received from the user serial port. tell the system what information it should receive from each serial interface port, CALREC Putting Sound in the Picture...
Repeat the process for all the GPI pins 24 <down arrow> until you see “Edge” - 31 Dolby Multichannel Audio Tool Model DP570 to Alpha Remote Connection Cable (fully isolated) Designed to be plugged in second remote card Dolby DP570 GPIO...
Digital I/O Rack. Each MADI interface can operate in either 56 or 64 channel mode and can transmit over a coaxial AND optical medium and receive over a coaxial OR optical medium. A switch allows receiver selection. 30 ALPHA with Bluefin...
I/O resources and control each mixing console, in a star formation. administration functions, leaving the data between Calrec digital consoles. Connections may be made with Category user free to creatively exploit network Hydra I/O units, with up to 96 inputs/...
MAC address Alpha can have up to 8 WAB interfaces. Switches are available in 1U or 2U against its own MAC address. There is a versions, and can have a combination...
When the internal ambient temperature the networking system to one or more reaches 60°C (140°F), the OVER TEMP Calrec digital consoles. red LED on the DC power supply unit will Dimensions 7U X 482mm (19 inch ) light.
Power USB 2 IEEE1394 Mic In Power Reset 491-043 switches, and the two switches are connected together. Alpha Control Surface Hydra I/O Rack 1 Gigabit Switch 1 HP Procurve 9 M D -T YPE Act FDx Max Switch 4104gl Reset...
Each output connector has a green LED to inches indicate that there is a route established to AD5603 24 mic/line in & 8 line out 12.5 it from a console on the network. AD5608 12 mic/line in & 4 line out 11.5 36 ALPHA with Bluefin...
Page 37
IP Addresses If a small format I/O unit needs to be connected together. Calrec will supply each device in your swapped out, the replacement unit must system with its own unique IP address, be programmed with the correct IP which the system uses to identify each address.
If a slot is occupied by a bulk I/O card, AES, BULK OR WAB H119 H120 then the AES I/O connectors belonging to that slot are left unused, and the SMB connectors for bulk I/O are used to connect to the analogue I/O racks. 40 ALPHA with Bluefin...
2 dedicated input connectors on SLOT CONNECTOR CONNECTOR the rear of the rack, to which the system’s analogue inputs are connected. Each of the input connectors provides connections for 4 stereo inputs. CALREC Putting Sound in the Picture...
8 or 12 way Ideally, the EDAC interface panels should slot has 2 dedicated input connectors EDAC interface panels via Calrec custom be located within 5m (16.5ft) of the on the rear of the rack (shown within cabling to achieve Style 1 (4 pairs per Analogue I/O Rack.
2 dedicated connectors are connected to 8 or 12 way input connectors on the rear of the rack EDAC interface panels via Calrec custom Ideally, the EDAC interface panels should (shown within dotted border), to which the cabling to achieve Style 2 (6 pairs per be located within 5m (16.5ft) of the...
On EDAC, the first pin is HOT (phase), the second pin is COLD 17 . 35 17 . 35 (anti-phase) and H.LL are chassis connections. 18 . 36 Chassis 18 . 36 Chassis 8 WAY EDAC INTERFACE PANEL SN5080 CALREC Putting Sound in the Picture...
Style 1 - 8 pairs per 38 way EDAC 17 . 35 18 . 36 Chassis On EDACs, the first pin is HOT (phase), the second pin is COLD (anti-phase) and 8 WAY EDAC INTERFACE PANEL H.LL are chassis connections. SN5080 52 ALPHA with Bluefin...
Page 53
Style 2 - 6 pairs per 38 way EDAC On EDACs, the first pin is HOT (phase), the second pin is COLD (anti- 8 WAY EDAC INTERFACE PANEL phase) and H.LL are chassis connections. SN5080 CALREC Putting Sound in the Picture...
These are general rules to follow, and compression than those on the inside. if in doubt, always refer to the cable Over-tightening deforms the twisted pairs manufacturer’s recommendations. CALREC Putting Sound in the Picture...
The chassis assemblies. Safety grounding is rear mounting brackets should be used provided via ground connections in the line when no support is provided under the cord entry receptacles. rack assembly, the rack should not be 84 ALPHA with Bluefin...
1RU front angles. The unit should always be mounted in a horizontal position. It is recommended that the rack is not supported by the front flanges alone. CALREC Putting Sound in the Picture...
Page 88
This publication is for International usage. Despite considerable effort to produce up Alpha is a trademark of Calrec Audio Calrec Audio Ltd to date information, no literature published Ltd.
Need help?
Do you have a question about the ALPHA and is the answer not in the manual?
Questions and answers