• Available settings: • Stand-by mode. • Minimum period between fast cycles. • Start and stop delay. • Volt-free contact for monitoring the alarms is displayed on the screen (only version A). Ascento Group Australia www.reefe.com.au P: 07 3893 5000 VER.2024.04.05...
Technical Characteristics Rated Motor Power 0,37-2,2 kW (SW1-SW2) Power Supply ~1 x 110-230 V (SW1-SW2) Electric Outlet ~1 x 48-230 Vac/Vdc (SW3) Dry contact (SW3) Nominal Pressure 1MPa/10bar (plus: 1.3MPa / 13bar) Frequency 50/60Hz ≥ 0.6 Protection degree IP55 Max water Temperature 50°C Max environment Temperature 60ºC Cut-in range (start pressure) 0.5÷7 bar (version plus=11 bar) Cut-out range (stop pressure) 1÷8 bar (version plus=12 bar)
The alarm code is displayed. STAND-BY Are displayed 3 flashing dots MODE BASIC CONFIG. The sequence of basic configuration parameters is displayed. MODE ADVANCED The sequence of advanced configuration parameters is displayed. CONFIG. MODE Ascento Group Australia www.reefe.com.au P: 07 3893 5000 VER.2024.04.05...
Page 6
LEDS STATE MEANING It indicates the instantaneous pressure in bar It indicates the instantaneous pressure in bar + pump operating (only ((O)) SW1/SW3) It indicates the instantaneous pressure in psi It indicates the instantaneous pressure in psi + pump operating (only SW1/SW3) It indicates the instantaneous current consumption in Ampere units (only SW2)
The unit is ready to operate but more optional adjustments can be set through basic and advanced MENUS. See the next chapter. Remark 1: it is important to enter the exact current specified on the nameplate of the pump. Ascento Group Australia www.reefe.com.au P: 07 3893 5000 VER.2024.04.05...
Basic Menu (diagram C) • Press simultaneously for 5 second duration. • The stop pressure value is displayed on screen, LED STOP lights up and display is flashing. • By mean of the values can be changed. • Press for validation. •...
Page 9
Anti-flooding configuration. If activated, it stops the pump after programmed time (in minutes) of continuous operation. Disabled (H00), 1 minute (H01)...99 minutes (H99) If we change rS0 to rS1 and push ENTER default values are restored. Ascento Group Australia www.reefe.com.au P: 07 3893 5000 VER.2024.04.05...
Note 2: Basic SWITCHMATIC 1/3 can only detect dry-running operation through the minimum pressure. This means that the installer must determine the water column of the installation, the start pressure of the pump and place the minimum pressure below the start pressure. Pressurise the system to reach shut off head and then press the OFF (power) button open the highest fixture, now taking note of the digital screen press ON (power) button again.
CF xxx 0-999999 Number of start-stop cycles Cr xxx Number of connecitons to the power supply 0-65535 A01 xxx Number of A01 alarms. 0-999 A02 xxx Number of A02 alarms. 0-999 Ascento Group Australia www.reefe.com.au P: 07 3893 5000 VER.2024.04.05...
A04 xxx Number of A04 alarms. 0-999 A05 xxx Number of A05 alarms. 0-999 A11 xxx Number of A11 alarms. 0-999 APM xxx Number of over-pressure alarms (---). 0-999 rPM x.x Maximum registered pressure. ENTER -> EXIT. -> All the alarms are restored expect the operation data. Warnings and Alarms COD.