Page 1
AMIRO U1 UltraLift Skin-lifting Ultrasound Home Device User Manual...
Page 2
* We appreciate you buying an AMIRO product. • For your safety, please read this manual carefully before use, and strictly follow the instructions provided. • Please save this manual for future reference. • Please include this manual when transferring ownership of the product to others.
Page 3
Instructions for Use Dear customer, thank you for choosing AMIRO U1 UltraLift Skin-lifting Ultrasound Home Device from Shenzhen Accompany Technology Co., Ltd. (“our company”). Before using the device, please ensure that you have carefully read and fully understood the user manual. To use the device properly, make sure the instructions are followed carefully.
Safety Instructions To use this device safely and to prevent bodily harm to the user or others, please read the safety precautions carefully and follow the precautions outlined. About the symbols and their meanings: Warning: Operations that could potentially harm the user or damage the device Caution: Additional instructions are provided for better device usage.
Page 7
Warning Biological Hazards and Contact Safety ● The components of this device that come into contact with the human body are crafted from high-purity aluminum alloy, non-toxic PCTG materials, and 17-4 stainless steel. These materials have successfully undergone nickel release (GB/T 19719-2005 & GB/T 28485-2012) and biocompatibility testing (GB/T 16886.5-2017 &...
Page 8
Warning: Precautions for the use of different stamping modes (intense mode, gentle mode) Face Mask ● When using this device for stamping treatment (Intense/Gentle Mode), it should be paired with AMIRO U1 UltraLift Timeless Four-zone Face Mask. Avoid using other face masks to prevent potential injury.
Page 9
Face mask + device ● When using this device for stamping treatment (Intense/Gentle mode), ensure that the device head's surface fully contacts both the face mask and facial skin. Avoid partial contact with the skin. [Figure 1] ● When stamping, make sure to follow the grid pattern precisely. [Figure 2, Figure 3] ●...
Page 10
Warning: Areas to be avoided for Express Mode ● Avoid using this device near the eye socket and eyeball to prevent tissue damage. ● To prevent tissue damage due to depth concerns, do not apply this device within 1.5 cm in front of the tragus, in the philtrum, around the mouth corners, in the nasal wings, within the throat, along the jawline (mandible), and within the thyroid and laryngeal regions.
Page 11
Warning: Instructions for using the gliding mode (Express mode) ● When using this device for gliding treatment (Express mode), ensure consistent contact between the device head and the face. Avoid any abrupt movements of the head during contact to prevent potential injury. [Figure 1] Gliding over the face with Do not shake the device appropriate amount of contact.
Page 12
● Feeling different temperatures while using the device is normal, as individual skin sensitivity differs. Adjust the temperature to your preference as necessary. ● To prevent skin damage or discomfort, it is recommended to avoid prolonged use on the same area. ●...
Page 13
● To prevent component failures or injuries from dropping the device, make sure to keep the main unit and base secure and stable to avoid any impact or falls. ● Do not use the device if it is malfunctioning as doing so may result in bodily injury or danger. ●...
Page 14
Warning: Electrical Safety ● Do not disassemble, repair, modify, or damage the main unit or charging cable. Do not bend, pull, or twist the power cord. ● Do not expose the main unit or charging cable to water or high humidity to prevent electrocution or leakage. Avoid charging, using, or storing the device in areas prone to moisture, such as bathrooms or sinks.
Page 15
Caution: Improper storage may reduce the lifespan of the device Proper storage is crucial for the effective use of this product. Position it on a secure surface and ensure the safeguarding of the device head. ● Keep the main unit and charging cable out of reach of children, infants, or pets. ●...
Contraindications and applicable scenarios People with any of the following conditions may not use this device as it could result in accidents or skin and bodily injury: ● Experiencing allergic reactions. ● Skin areas with impaired integrity. ● Skin areas with damage, acute inflammation, active infections, rosacea, ongoing vitiligo, or severe acne. ●...
Page 17
● Individuals using life-sustaining electronic devices such as heart-lung machines. ● Individuals using wearable medical devices such as electrocardiographs, infusion pumps. ● Suffering from, or having previously suffered from, cancer (especially skin cancer and precancerous moles), acute illnesses, tuberculosis, febrile diseases, infectious diseases, blood diseases, visceral diseases, skin diseases, or allergic dermatitis ●...
Additionally, L-Ergothioneine curbs the expression of TNF-α and MMP-1 in dermal fibroblasts, combats free radicals, and decreases lipid peroxidation. ● In conjunction with the AMIRO U1 UltraLift Timeless Face Lifting Gel, low molecular weight collagen penetrates deeply into the skin, stimulating collagen production.
Page 19
Enhancing penetration: 1+1>2 Through replicating the human dermis layer composition and providing essential elements such as collagen, fibronectin, elastin, hyaluronic acid sodium, and more to the skin, this treatment stimulates collagen synthesis synergistically, tightening the skin and refining facial contours as a result. Recombinant III-type collagen directly reinforces the skin barrier Epidermis...
*Refer to the Energy Box Assembly & Disassembly Power Button/Intensity Instructions for Specific Operations Level Button/Mode Button Intensity Level Indicator Power indicator Charging Cable ×1 AMIRO U1 UltraLift Skin-Lifting User Manual & Instructions Ultrasound Home Device *1 Charging Base*1 Cleaning Pad*1 Charging port...
Product Features Power indicator When the device is turned off, press the red power button Mode/Function Description Amiro Ultrasonic Facial Skin-Tightening Machine briefly to check the battery level Intense Mode 3 intensity Ultrasonic + Microcurrent + Intelligent Zone Recognition + ...
Product Usage Prep and Safety Tips for First Use Open-box checking: Unpack the device and its accessories, cross-check them against the packaging list, and keep the packaging materials for transport, storage, and reference in the future. Check the device and accessories for any damage. If there are signs of mechanical damage or equipment malfunction, do not use the device and contact the distributor or after-sales service immediately.
Page 23
Caution: ● Do not use the device continuously in the same area. ● If a strong tingling sensation is felt on the skin, lower the intensity or move to a different area. ● A mild tingling sensation near the cheekbones, jawline, or teeth during use is considered normal and safe. ●...
How to Use the Product Jewelry 1. Cleanse your face 2. Prepare the product 3. Apply the face mask After washing your face, ensure it is Press the button once to check the battery Take the mask out of its package. Place the thoroughly dry.
Product Instructions Switch on Device Press and hold the red power button until you feel a vibration. Mode Switching Smart Sensor Smart Recognition Light Double-click the red power button. Mask color display during stamping Intensity Level Switching White for Quick Mode Click the red power button once Mode indicator on Intense Mode...
Page 26
Select Mode Double-click to switch between modes: Intense Mode → Gentle Mode → Express Mode Double- click Intense Mode Gentle Mode Express Mode * Once treatment for a certain mode is finished, the device will vibrate and shut down. To select a different mode, switch on the device again and choose your preferred setting.
Mode Description and Switching [Intense Mode] Matching skincare product Timeless Face Lifting Mask Mode Indicator Light: Orange Smart Recognition Light Eye Contour Forehead Middle area Lower Jaw face Treatment Areas: Whole Face Matching Methods Stamp sequentially according to the numbers. Skincare routine for the Stamp the whole face Stamp each section three times.
Page 28
[Gentle Mode] Matching skincare product Timeless Face Lifting Mask Mode Indicator Light: Green Smart Recognition Light Forehead Eye Contour Middle area Lower Jaw face Treatment Areas: Whole Face Matching Methods Stamp sequentially according to the numbers. Skincare routine for the Stamp the whole face Stamp each section three times.
Page 29
AMIRO BEAUTY U1 UltraLift Timeless Four-zone Face Mask Working principle illustration: Dermal-epidermal junction (DEJ): promoting the synthesis of Type V and Type XVII collagen. Loss of moisture Foreign substance Recombinant III-type collagen directly reinforces the skin barrier Small molecule collagen...
Page 30
• After 50 seconds of use, the transmission with minimal loss, device will vibrate briefly, recommended to utilize Amiro’s standard gel or prompting a zone change to the coupling agent. right cheek. 2. Avoid gliding over the same area more than three times consecutively.
After Skincare Press hold ② Device Maintenance: ③ Subsequent Skincare: ① Automatic Shutdown: • The device will vibrate for an extended duration and After switching off the device, use a soft, • Applying a mask for 10-15 minutes after using automatically switch off after completing skincare in damp cloth or a damp paper towel to wipe the device is recommended.
Main Technical Parameters Conditions for Product Operation How to charge the mirror: Ambient Temperature: +5°C to +35°C Verify that the device is fully charged during the first use Relative humidity: 15%-90% Charging time: ~120 minutes (charging time may vary depending on charging Rated input: Type-C 5 V ⎓...
Product maintenance ● To prevent electrocution, keep the device dry and avoid immersing it or any other parts in water. ● Store the device and its accessories properly after each treatment to prevent damage or loss. Remember to clean the device before putting it away. ●...
Product troubleshooting Possible causes Solutions Possible causes Solutions High temperature, lifespan of Use the device after it has been Smart recognition light Battery depleted energy box expired, unstable charged flashing red connection of energy box Contact the manufacturer for Not being used for an Device shuts off after Unable to start End of battery life...
Page 36
Level 1 to build tolerance the skin Unlock higher energy levels using Amiro’s WeChat Mini-Program Choosing the wrong Double-click to switch to Gentle level and mode Mode for a softer experience Ultrasound is used in this procedure Deactivate the microcurrent using to generate warmth beneath the skin.
Main safety properties Input: Type-C 5 V ⎓ 3A, 15 W。 The device is rated IPX6 for liquid resistance. Explanation of graph and symbol Symbol Explanation Symbol Explanation Symbol Explanation Symbol Explanation Fragile items, handle Warning Read user manual Keep dry with care Standby/Power Direct current...
Waste disposal declaration Disposal of used battery: ● Do not attempt to replace the battery on your own during regular use. ● Battery leakage risk: Battery electrolyte is corrosive and should not be in direct contact with the skin or clothing. Promptly the area with a dry cloth if contact occurs.
Hazardous Substance Label Component names Names and concentrations of toxic or hazardous substances or elements in the product Toxic or hazardous substances or elements Lead Mercury Cadmium Hexavalent Polybrominated Polybrominated chromium biphenyls diphenyl ethers (Pb) (Hg) (Cd) (Cr(VD) (PBB) (PBDE) ×...
Warranty Policy and Warranty Certificate Chinese Mainland ● Customers who purchase this product within Chinese Mainland are covered by a 1-year warranty. Warranty periods begin with the date of receipt for online purchases (unless proven otherwise, logistics receipt dates are taken for online purchases; for physical transactions, physical delivery dates are taken for physical transactions).
Page 41
Please be aware that the following situations are not covered by the free warranty service during the warranty period: ● Damage caused by improper use, such as incorrect power supply connection, use of inappropriate accessories, failure to follow the instructions, incorrect use, or damage caused by negligence, etc.
Need help?
Do you have a question about the U1 and is the answer not in the manual?
Questions and answers