Download Print this page

Advertisement

Quick Links

SAFETY
Read and understand this installation and operating manual as well as the controls manual before operating your kiln. If you have any questions please
contact Evenheat Kiln at 989-856-2281 or at evenheat-kiln.com.
Kilns are as safe as any other electrical appliance when used under normal and proper operating conditions. To create and maintain this safe environment
observe all safety precautions.
Warning Symbol Descriptions
Warning symbols are used throughout this manual. These symbols alert the operator to certain hazards and important information. Pictured below
are symbols used along with a description of each.
The Exclamation Point alerts you to particular cautions, hazards and information.
The Lightning Bolt alerts you to specific information regarding the risk of electric shock.
Electric shock may result in injury or death.
The Heat Waves alert you to specific information regarding the risk of burn injury.
Emergency Shut Off Provision
The kilns power supply connection (plug/receptacle, breaker or disconnect) acts as the emergency electrical power shut off. Access to these
devises should be unobstructed and safe at all times.
All electrical installations for direct wired models (those without a plug/receptacle connection) must include a power disconnect near the kiln and that
is easily accessible and safe for emergency power shutoff.
Electrical Safety
A licensed electrician should be used for all electrical installation and service. All applicable local, state and federal electrical codes must be
followed.
Use correct voltage, wire size and fuse or breakers. Kiln electrical requirements are located on the kiln nameplate. Make sure all electrical connections
are tight. Avoid using aluminum wire.
Always use the proper electrical receptacle. Never alter the kiln cordset or cordset plug. Alterations can be dangerous. Alterations will void any
warranties along with nullifying any Listing Agency markings.
Evenheat recommends that a voltage check be performed before placing the kiln into service, ideally before actual purchase. Operating
voltage varies. The kilns operating voltage (printed on the kilns nameplate) must match the applied voltage (actual electrical service voltage).
If it does not, do not install or operate the kiln as potential electrical and fire hazards exist. Contact Evenheat for guidance in such cases.
The kiln must be properly grounded.
Unplug or disconnect the kiln from the electrical service before accessing the chamber for servicing or vacuuming. Do not attempt to touch
or replace the heating elements while the kiln is plugged in or connected to the electrical service. Electric shock may result in serious injury
or death.
Never, ever use an extension cord to operate a kiln.
The Studio Pro 17 consumes 18A at 120V. The power circuit requires the use of a "Fully Rated" 20A breaker.
Studio Pro 17 STP/RM
Installation and Operating Manual
April 2021
Page 1 of 10

Advertisement

loading
Need help?

Need help?

Do you have a question about the Studio Pro 17 STP/RM and is the answer not in the manual?

Questions and answers

Summary of Contents for Evenheat Studio Pro 17 STP/RM

  • Page 1 The kilns operating voltage (printed on the kilns nameplate) must match the applied voltage (actual electrical service voltage). If it does not, do not install or operate the kiln as potential electrical and fire hazards exist. Contact Evenheat for guidance in such cases.
  • Page 2 Do not place or use kiln on combustible surface. Place only on the metal stand provided by Evenheat Kiln, Inc. The surface on which the kiln is placed shall be capable of safely supporting the combined weight of the kiln, kiln load and any operating personnel.
  • Page 3 Replace any worn, damaged or defective parts immediately with Evenheat Kiln replacement parts only. Discontinue use until parts are replaced. When vacuuming the kiln use only HEPA filters on the vacuum. Prolonged expose to brick dust and other refractory materials can cause lung injury.
  • Page 4 Studio Pro 17 STP/RM Installation and Operating Manual April 2021 Studio Pro 17 Features Dual Access Design The Studio Pro 17 features a Dual Access Design. The Dual Access Design simply means you have the choice of entering the chamber through the Top or through the Front.
  • Page 5 Studio Pro 17 STP/RM Installation and Operating Manual April 2021 Kiln Setup and Placement Kiln Location Place your Studio Pro 17 in a location that offers a level, non combustible surface. The Studio Pro 17 should be placed no closer than 12” from any wall or 36”...
  • Page 6 Studio Pro 17 STP/RM Installation and Operating Manual April 2021 Place the plastic stand feet on the stand legs. The stand is now complete. Place the Studio Pro 17 on the stand as shown and secure the kiln base to the stand. Your Studio Pro 17 base came with 4 nuts and bolts for this purpose.
  • Page 7 Studio Pro 17 STP/RM Installation and Operating Manual April 2021 Insert a bolt through each side of rear base and stand frame angle and secure with nut. Your Studio Pro 17 is now properly secured to the stand. Page 7 of 10...
  • Page 8 “papers” available. You DO NOT want to fire your ware directly on the floor of the kiln. Doing so will most likely allow your ware to stick to the floor and damage it, and that’s no fun. If you have not prepared your shelf do so now. If you’re using Evenheat supplied shelves and wash there are separate instructions included with these items.
  • Page 9 Studio Pro 17 STP/RM Installation and Operating Manual April 2021 To load via the front, throw the kiln control panel power switch to the OFF position and simply lift on the front chamber handle and take the chamber back. A built-in stop will hold the chamber at the open position. Place your shelf squarely onto the floor of the Studio Pro 17.
  • Page 10: This Warranty Does Not Cover

    ARRANTY Evenheat Kiln, Inc. guarantees to the original purchaser that for a period of two full years (1 year for Superwool lids) from the date of purchase the kiln will be free of defects in workmanship and materials when used under normal and proper operating conditions. Evenheat will replace or repair any defective part as specified..

This manual is also suitable for:

Studio pro stp