BD603 Series
Solar Water Pump Inverter
Manual
Driving Follow Heart,Winning The Future

Advertisement

loading
Need help?

Need help?

Do you have a question about the BD603 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Folinn BD603 Series

  • Page 1 Driving Follow Heart,Winning The Future www.chinafolinn.com BD603 Series Solar Water Pump Inverter Manual ZHEJIANG NEW FOLINN ELECTRIC CO.,LTD Add:No.2 Jinhuan Road, Chengbei Street, Wenling City, Zhejiang,China Tel:+86-576-86421218 Fax:+86-576-86421168 http://www.chinafolinn.com...
  • Page 2 Praface Preface Thanks for choosing the BD603 series solar pump inverter produced by Zhejiang New Folinn Electric Co,Ltd. BD603 series solar pump inverter is high performance vector control inverter special for solar pump.This inverter is supply by PV panel and no need battery .It can realize excellent...
  • Page 3 Chapter 1 Chapter 1 Product Brief Introduction Catalogue 1.1 Technical Features Description Technical Features Chapter 1 Product Brief Introduction - - 1 Input AC voltage 1AC 220V±15%, 3AC 220V±15%,3AC 380V±15% 1.1 Technical features - - 1 Recommend pv input 160~380VDC; Input DC voltage range 350~750VDC...
  • Page 4 Input 3 Phase 220V±15%; Recommend DC 160V 380V 0 1 B 3 4 1 3 A 1 1 5 2 5 1 0 0 1 Serial number BD603-0R5G-2 0.55 0.55 ZHEJIANG NEW FOLINN ELECTRIC CO.,LTD BD603-0R7G-2 0.75 0.75 BD603-1R5G-2 BD603-2R2G-2 11.5 10.0...
  • Page 5 Chapter 1 Chapter 1 1.Jumper function declaration of main board: 1.4 Basic wiring diagram AI1: Analogue input 1 voltage/current signal conversion Main circuit terminal AI2: Analogue input 2 voltage/current signal conversion PV panel Solar panel Cotrol circuit terminal V: 0-10VDC voltage signal input protection diode I: 0-20mA analog current signal input AO1: Analog output 1 voltage/current signal conversion...
  • Page 6 Chapter 1 Chapter 2 Chapter 2 Operation and Display 4.Control circuit terminal and wiring 2.1 Keypad description 1)Schematic diagram of control circuit wiring terminal ● Keypad explanation and function AO1 AO2 ACM SG+ SG- ,and can be divided into two parts:display area Keypad locates above inverter DCM S3...
  • Page 7 Press Press setting frequency 2.2 Function code examining and modifying methods explanation: operation frequency Press The operation panel for BD603 series inverter adopts three-level menu structure for parameter setting and other operations.The three-level menus respectively are: output current Press functional parameter group(first-level menu)→function code (second-level menu)
  • Page 8 (Bold means flash bit): 2.4 Password setting: BD603 series inverter provide user password defensive function. When F07.00 is set to non-0, it is user password. While quit function code editing state, password protection will take effect. Press PRGM/ESC again to enter function code editing...
  • Page 9 Chapter 3 Chapter 3 Chapter 3 Introduction of Function & Parameter Function Parameter Name Setting Range Default Code F00.03 Max.output frequency 50.00Hz~600.00Hz 50.00Hz Group F00: Standard Function Parameters It is used to set the maximum output frequency of the inverter. It is the basis of the frequency setting, as well as the foundation of acceleration and deceleration speed.
  • Page 10 Chapter 3 Chapter 3 Acceleration time indicates the time required by the i to accelerate from 0 Hz to nverter The initial value of the set frequency is the value of F00.10 (Preset frequency). You can "Acceleration/Deceleration base frequency" (F00.03). change the set frequency by pressing keys ∧...
  • Page 11 Chapter 3 Chapter 3 Group F02: Motor 1 Parameters Function Setting Range Parameter Name Default Code Function Parameter Name Setting Range Default Code 0:no operation Model Rated power of 1: restore factory defaults,not Function parameter F02.01 0.1kW~1000.0kW F00.28 dependent asynchronous motor 1 include motor parameter restore Rated frequency of...
  • Page 12 Chapter 3 Chapter 3 The parameters in F02.06 to F02.10 are asynchronous motor parameters. These Group F04: V/F Control Parameters parameters are unavailable on the motor nameplate and are obtained by means of motor self-learning. Only F02.06 to F02.08 can be obtained through static motor auto-tuning. Through Group F04 is valid only for V/F control.
  • Page 13 Chapter 3 Chapter 3 F04.15 indicates the time required for the output voltage to rise from 0 V to the rated motor Function voltage shown as t1 in the following figure. Parameter Name Setting Range Default Code Output voltage 0.0%:(auto torque boost) Model Motor 1 torque boost F04.01...
  • Page 14 Chapter 3 Chapter 3 Description Value Function Sx(FWD) Sx(FWD) command command STOP STOP The inverter blocks its output, the motor coasts Reverse to rest and is not controlled by the inverter. Sy(REV) Sy(REV) STOP It is the same as coast to stop described in freely stop Forward AC drive...
  • Page 15 Chapter 3 Chapter 3 Group F06: Output Terminals Function Parameter Name Setting Range Default Code The BD603 provides 2 analog output (AO) terminal, 1 open-collector switch signal output, F05.18 AI1 lower limit 0.00V~F05.20 0.00V 2 relay terminal and a HDO terminal. Corresponding setting of -100.0%~+100.0% F05.19...
  • Page 16 Chapter 3 Chapter 3 Value Function Description Function Parameter Name Setting Range Default Code The AC drive judges whether the motor load exceeds the overload pre-warning threshold 0: Positive logic motor overload before performing the protection action. If the 1: Negative logic pre-warning pre-warning threshold is exceeded, the terminal Unit's digit: HDO...
  • Page 17 Chapter 3 Chapter 3 Group F08: Auxiliary Functions Function Parameter Name Setting Range Default PID setting Code PID feedback value Running mode when set 0:run at frequency lower limit frequency lower than F08.14 1: stop input terminal status frequency lower limit 2: run at zero speed output terminal status AI1 voltage (V)
  • Page 18 Chapter 3 Chapter 3 Function Group F09: Fault and Protection Parameter Name Setting Range Default Code F08.61 Under-voltage point 60.0%~140.0% 80.0% Function Setting Range Parameter Name Default Code Action selection at 0: Invalid Voltage class Under-voltage point base value instantaneous power 1: Decelerate F09.02 Single phase 220V...
  • Page 19 Chapter 3 Chapter 3 It is used to record the types of the most recent three faults of the inverter. 0 indicates no Function Parameter Name Setting Range Default fault. Code F09.20 Time interval of fault auto reset 0.1s~100.0s 1.0s Function Setting Range Parameter Name...
  • Page 20 Chapter 3 Chapter 3 This parameter is used to select the feedback signal channel of process PID. Group F10: Process Control PID Function The PID feedback is a relative value and ranges from 0.0% to 100.0%. PID control is a general process control method. By performing proportional, integral and Function Setting Range Parameter Name...
  • Page 21 Chapter 3 Chapter 3 Function Parameter Name Setting Range Function Default Setting Range Code Parameter Name Default Code ~ Proportional gain Kp2 F10.15 0.0 100.0 70.0 ~ F10.09 PID deviation limit 0.0% 100.0% 0.3% ~ F10.16 Integral time Ti2 0.01s 10.00s 2.00s If the deviation between PID feedback and PID setting is smaller than the value of F10.09, PID control stops.
  • Page 22 Chapter 3 Chapter 3 Group F16: Solar water pump special function Function Parameter Name Setting Range Default Code Function 0:reset when stop Parameter Name Setting Range Default Stop reset of MPPT Code F16.07 search voltage 1:no reset when stop : Control mode invalid Solar operation F16.00 CVT mode...
  • Page 23 Chapter 4 Chapter 3 Chapter 4 Commissioning guide Function Setting Range Parameter Name Default Code Wiring and commissioning steps Operation time of water F16.13 0 ~60000s pump underload 1.Wire according to the diagram and check the wiring is correct or not and then switch on Set the operation time of underload operation.Under the continuous underload operation, it will report (E-Pt) if the operation time is reached.
  • Page 24 If the F16.06=480V (maximum reference voltage). fault cannot be rectified, contact the agent or Folinn. (c)If the rated motor voltage is 220V, F16.05=340V (minimum reference voltage), E033 is the AC drive hardware overcurrent or overvoltage signal. In most situations, F16.06=280V (maximum reference voltage).
  • Page 25 Chapter 5 Chapter 5 Display Fault Name Possible Causes Solutions Display Fault Name Possible Causes Solutions 1. reduce the load and check 1.The load is too heavy or the motor and mechanical lockedrotor occurs on the 1.AC drive output circuit is 1.eliminate external faults AC drive condition.
  • Page 26 Chapter 5 Chapter 5 Display Fault Name Display Fault Name Possible Causes Solutions Possible Causes Solutions Current 1.the HALL device is faulty. 1.replace the faulty HALL device. 1.reduce the load and check the detection E015 2.replace the faulty drive board. 2.the drive board is faulty.
  • Page 27 Chapter 5 Chapter 5 5.2 Common Faults and Solutions Fault Possible Causes Solutions You may come across the following faults during the use of the AC drive. Refer to the 1.check and reset the parameters following table for simple fault analysis. in group F05.
  • Page 28 Appendix 1 Appendix 1 Appendix 1 External Dimension Power Dimensions (mm) Base Model Housing (kw) A-width H-height D -depth BD603-0R5G-2 0.55kW 1.External dimension : wall-mounted housing BD603-0R7G-2 0.75kW 116 175 146 103 165 BD603-1R5G-2 1.5kW Wall -mounted plastic BD603-2R2G-2 2.2kW housing 134 251 173 121 238 BD603-004G-2...
  • Page 29 Appendix 2 Appendix 2 Recommended PV panel -52-...