Introduction
Purpose
This document provides installation instructions for Gasboy
Kits.
Table of Contents
Topic
Introduction
Important Safety Information
Installation of the 9800A/2600A Pump Interface Kit
Pulse-out I/F Board (M06587A001) Jumper Settings
Required Tools
The following tools are required for the installation of the kits:
• Phillips
• Wrench
Parts List
The following table lists the parts included in the Pump Interface Kits, C06482 and C07357.
Item
1
2
3
4
Note: The C07357 kit is for use on single-sided dispensers only.
MDE-4863 Gasboy® 9800A or 2600A Pump Interface Kits Installation Instructions · October 2009
Screwdriver
®
Description
Pump I/F PCB
Standoff, M/F 6-32 3/4"
Washer, #6 External Tooth
Screw, 6-32 x 3/8
Gasboy
9800A or 2600A Pump Interface Kits
®
®
Page
1
3
5
9
Quantity
Part Number
C06482
M06587A001
1
C08381
2
068843
2
C08759
2
MDE-4863
Installation Instructions
October 2009
9800A/2600A Pump Interface
C07357
1
2
2
2
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 2600A and is the answer not in the manual?

Questions and answers

Summary of Contents for Gasboy 2600A

  • Page 1 Standoff, M/F 6-32 3/4” C08381 Washer, #6 External Tooth 068843 Screw, 6-32 x 3/8 C08759 Note: The C07357 kit is for use on single-sided dispensers only. MDE-4863 Gasboy® 9800A or 2600A Pump Interface Kits Installation Instructions · October 2009 Page 1...
  • Page 2: Related Documents

    For information on warranty, refer to MDE-4255 Gasboy’s Warranty Policy Statement. If you have any warranty-related questions, contact Gasboy’s Warranty Department at its Greensboro location. Page 2 MDE-4863 Gasboy® 9800A or 2600A Pump Interface Kits Installation Instructions · October 2009...
  • Page 3: Important Safety Information

    • A total electrical shut-off of the affected unit(s) or leaking fuels cause vapors. Even filling customer tanks will cause potentially dangerous vapors in the vicinity of the dispenser or island. MDE-4863 Gasboy® 9800A or 2600A Pump Interface Kits Installation Instructions · October 2009 Page 3...
  • Page 4 Subpart S of 29 CFR Part 1910 - Electrical Hazards, 29 CFR Part 1910.333 contains specific Lockout/ Tagout provision for electrical hazards. Page 4 MDE-4863 Gasboy® 9800A or 2600A Pump Interface Kits Installation Instructions · October 2009...
  • Page 5 Remove the two bolts located over the tabs of the Bezel Assembly. Lift the Bezel Assembly upwards and out to remove. Figure 2: Removing the Bolts on the Front Panel Bolts MDE-4863 Gasboy® 9800A or 2600A Pump Interface Kits Installation Instructions · October 2009 Page 5...
  • Page 6 Figure 3: Removing the Screws on the Front Panel Screws Pull the connector off P1on the Power Supply. After a few seconds, reconnect P1 (see Figure Figure 4: Power Supply Page 6 MDE-4863 Gasboy® 9800A or 2600A Pump Interface Kits Installation Instructions · October 2009...
  • Page 7 Figure 5: Side View 6-32 Screw Standoff CPU PCB Washer Connect the Pump I/F PCB to P8 of the CPU PCB. Secure the PCB using two 6-32 screws. MDE-4863 Gasboy® 9800A or 2600A Pump Interface Kits Installation Instructions · October 2009 Page 7...
  • Page 8 Connect the wiring between the Card System and DC Junction Box as shown in MDE-4341 Series 9800A/9800Q Pump and Dispenser Installation/Operation Manual. Secure the Display Panel in the upright position. Page 8 MDE-4863 Gasboy® 9800A or 2600A Pump Interface Kits Installation Instructions · October 2009...
  • Page 9 JP3 Open Pulse-out Side 1 Pulse-out Side1A Green Pulse-out Side 2 Pulse-out Side1B White Common Return Side 1A Return Black No Connection Side 1B Return MDE-4863 Gasboy® 9800A or 2600A Pump Interface Kits Installation Instructions · October 2009 Page 9...
  • Page 10 Pump I/F Board (M06587A001) jumpered to provide two pulse outputs, one from each Pulser (C06482 kits). Figure 7: Single-channel, Dual/Single-hose Pulse-out I/F Page 10 MDE-4863 Gasboy® 9800A or 2600A Pump Interface Kits Installation Instructions · October 2009...
  • Page 11 Automotive and Marine Service Station Code (NFPA 30A) and regulations. Canadian users must also comply with the Canadian Electrical Code. 2) Refer to MDE-4341 Series 9800A/9800Q Pump and Dispenser Installation/Operation Manual for complete installation instructions. MDE-4863 Gasboy® 9800A or 2600A Pump Interface Kits Installation Instructions · October 2009 Page 11...
  • Page 12 Screw Co. © 2009 GASBOY 7300 West Friendly Avenue · Post Office Box 22087 Greensboro, North Carolina 27420 Phone 1-800-444-5529 · http://www.gasboy.com · Printed in the U.S.A. MDE-4863 Gasboy® 9800A or 2600A Pump Interface Kits Installation Instructions · October 2009...

This manual is also suitable for:

9800a

Table of Contents