Technische Alternative CORA-HKT Manual

Technische Alternative CORA-HKT Manual

Radiator thermostat

Advertisement

Quick Links

Technische Alternative RT GmbH
A-3872 Amaliendorf, Langestrasse 124, Austria
The CORA-HKT radiator thermostat is used to control the flow rate in radiators, underfloor heating
systems, wall heating systems and similar.

Table of contents

Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Cable connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Battery operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Wireless system. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Relaying wireless signals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Initialisation run . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Opening the device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
LED status indicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Output variables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Fault codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Input variables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Device information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Dimensions in mm. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Tel +43 (0)2862 53635
Radiator thermostat
mail@ta.co.at
CORA-HKT
 
Vers. 1.00.1
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CORA-HKT and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Technische Alternative CORA-HKT

  • Page 1: Table Of Contents

    Vers. 1.00.1 Radiator thermostat The CORA-HKT radiator thermostat is used to control the flow rate in radiators, underfloor heating systems, wall heating systems and similar. Table of contents Installation ............... . 2 Cable connection .
  • Page 2: Installation

    If the CORA-HKT is powered by batteries, it cannot be used as a HOP (see Relaying wireless signals). Cable connection The CORA-HKT can be just powered (12 V) by cable or can be both powered and operated by cable (CORA-DL). The DL bus is not protected against reverse polarity.
  • Page 3: Wireless System

    The CORA-HKT can also be used to relay wireless signals from other devices, but only if it is powered via a cable. If it receives signals via a relay, it automatically returns data via the same relay. No set- tings are therefore required for the relay on the CORA-HKT.
  • Page 4: Initialisation Run

    Initialisation run As soon as the HKT is supplied with power, it immediately starts an initialisation run. It should there- fore already be installed when the power is switched on. If this is not the case, carry out a restart after installation by clicking the button (see "Button").
  • Page 5: Led Status Indicator

    LED status indicator The LEDs on the device indicate various operating states. Green, flashes quickly The button has been double-clicked – wireless pairing is enabled for 5 minutes (the LED flashes for just 3 seconds, not for the whole 5 minutes). Orange, flashes every 10 Valve was not found (fault code 4).
  • Page 6: Input Variables

    Input variables The following values can be sent to the CORA-HKT (cannot be changed). Room temp. The current room temperature can also come from an external sensor. Help- [°C] ful if the room temperature recorded by the HKT itself is not reliable.
  • Page 7: Output Variables

    Output variables The following values are transmitted from the CORA-HKT to the paired/wired device (cannot be changed): Timeout Digital value Yes/No (Yes if connection lost) Battery status Battery state of charge (0-100 %) Eff. room temp. The room temperature used for the calculation.
  • Page 8: Programming

    Programming The CORA-HKT is incorporated into the programming of the connected controller. We recommend the TAPPS2 PC software for this. This is available to download free of charge at www.ta.co.at/down- load/software/. Version 1.20 of TAPPS2 is required as a minimum.
  • Page 9: Dimensions In Mm

    Dimensions in mm Technical data Batteries 2x AA (not supplied) Battery service life Can vary depending on battery and motor activity; typically 2 years Bus load CORA-DL Power consumption 12 Depending on motor activity max. 3 W (standby typically 0.1 W) Thread M30x1 fine thread Permissible ambient...
  • Page 12 EU Declaration of conformity Document-Nr. / Date: TA21024 / 08.11.2023 Company/Manufacturer: Technische Alternative RT GmbH Address: A-3872 Amaliendorf, Langestraße 124 This declaration of conformity is issued under the sole responsibility of the manufacturer. Product name: CORA-HKT Product brand: Technische Alternative RT GmbH...
  • Page 13 Note: The following guarantee conditions do not limit the legal right to a warranty, but rather expand your rights as a consumer. 1. Technische Alternative RT GmbH provides a one year warranty from the date of purchase for all the devices and parts which it sells. Defects must be reported immediately upon detection and within the guarantee period.

Table of Contents