355 Bayview Avenue, Amityville, NY 11701
Phone: 631-842-9400 ● Fax: 631-842-9135
www.napcoaccesspro.com
A NAPCO SECURITY GROUP COMPANY
Publicly traded on NASDAQ
CAUTION: Before handling the Network Interface
Board, use a grounding strap (or touch the Con-
troller PCB metal chassis) to reduce the possibility
of static discharge.
1. Remove power from the SUPER TWO
teries, then remove the 6-pin Molex connector marked
"Power In" located inside the housing at the lower-right side
of the control panel (see Fig. 1). Wait several seconds to
ensure that all power LEDs are off.
Note: If the 2MB Memory Expansion Board is installed as
per Appendix A in WI1265, the installation instructions for
the CIC1300NETBD2 will be slightly different (the differ-
ences will be noted in steps 3 & 4, below). The required
spacers and flexible shield are included in the kit
(9CICP13NET2BAG).
2. On the Super Two main PC board, remove the metal
screw (4-40 1/4" Phillips pan-head) from the top left
mounting hole. Into this mounting hole, screw in the 7/16"
round metal standoff hand tight (see Fig. 2). HINT: Before
installing the Network Interface Board, make a note of its
MAC Address (located on a label).
Note: The Network Interface Board cannot be used in con-
junction with RS232 polling. Before installing the Network
Interface Board, remove any wires that may be connected to
your controller on J5 pins 4, 5 and 6.
3. Place the Network Interface Board on top of the main
board at the upper left corner (parallel to the top), as shown
in Fig. 3. (1) Align the standoff hole in the Network Interface
Board with the metal standoff installed in step 2. (2) If the
Memory Expansion Board is not installed, first snap in the
Long Nylon Double Sided "Snap-In" Standoff onto the
main PC board (see Fig. 3 for placement). If the Memory
Expansion Board is installed, place the Short Nylon Dou-
ble Sided "Snap-In" Standoff onto the main board first,
Fig. 1: Remove Power
Metal Standoff
Long Nylon Double
& Metal
Sided "Snap-In"
Phillips Screw
Standoff
Fig. 3: CICP1300NETBD2 Without Memory Expansion Board.
1
Super Two
CICP1300NETBD2 w/ Peer-to-Peer Lockdown
Symbol: NSSC
®
. Disconnect bat-
Power
Connector
Network Interface Board
®
Installation Instructions
© NAPCO 2024
then into the hole on the bottom of the Memory Expansion
Board.
(3) Place the Thin Nylon Spacer between the
Memory Expansion Board and the Network Interface Board
(see Fig. 4 for placement).
4. Visualize all connectors & secure the Network Interface
Board. Align and press to insert all pins of the Network
Interface Board with the JP3 connector on the main PC
board. If you are not using a Memory Expansion Board, first
carefully snap-in the Long Nylon Double Sided "Snap-In"
Standoff that was installed on the main PC board into the
Network Interface Board, then screw the 4-40 1/4" Phillips
pan-head metal screw into the metal standoff (see Fig. 3).
If using a Memory Expansion Board, screw in the 4-40 1/4"
Phillips pan-head metal screw into the metal standoff and
also screw in the Nylon Screw to secure the Memory Ex-
pansion Board (see Fig. 4). Check to ensure correct align-
ment.
5. Install flexible shield: (Required for FCC compliance;
allows use of unshielded network cable). Install Cable
Clamp to the knockout nearest the Network Interface Board
on the left side of the metal enclosure. Insert the CAT5 or
CAT6 Network UTP cable through the cable clamp, slip the
3-inch flexible shield over the cable, then plug in the CAT5
or CAT6 Network UTP cable into the Network Interface
Board. Slide the shield so the left side is under the clamp,
then gently tighten the clamp to secure the cable and shield
in place. Important: Pull the shield snugly over Ethernet
cable--DO NOT extend shield over jack.
6. Restore power.
marked "Power In", then reconnect batteries.
"OK" lamp located in the center of the PC board is blinking
at a rate of approximately once every second. Verify the
LEDs next to the Ethernet jack are lit and are blinking upon
connection (for LED functions, see page 2).
Network
Interface Board
Super Two PC Board
Top Left Mounting Hole
Fig. 2: 7/16" "Screw-on" Metal Standoff.
Metal
Standoff
& Metal
Phillips
Screw
Memory
Expansion
Board
Fig. 4: CICP1300NETBD2 with Memory Expansion Board.
Super Two® Network Interface CICP1300NETBD2 Installation Instructions
Reconnect the 6-pin Molex connector
4-40 1/4"
Pan-head Screw
7/16"
"Metal" Standoff
WI2424ALF 3/24
Verify the
Nylon
Screw
Thin
Nylon
Spacer
Short Nylon Double
Sided "Snap-In"
Standoff