RADIANCE DIRECT VBNT
HBATBK
KDV40
OWNER'
s
GUIDE
INSTALLATION, OPERATION AND MAINTENANCE
PROCEDURES FOR USE IN NORTH AMERICA
Models #2770 and #2776
WARNING
If you do not follow these instructions
exactly, a fire or explosion may result
causing property damage, personal injury
or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Shutt off the gas supply.
Open windows; do not touch any electrical
switches.
• Do not try to light any appliance; extinguish any
open flame.
• Do not use the phone in your tiuilding.
Immediately call your gas supplier from a
neighbor's phone.
Follow the gas supplier's instructions.
If you cannot reach your gas supplier, phone
the fire department.
Installation and service must be performed
by a qualified installer, service agency or
the gas supplier.
SAVE THIS MANUAL FOR
FUTURE REFERENCE
Tested and listed to ANSI Z21.88-1998
and CSA 2.33-M98
AVERTISSEMENT
.
Quiconque ne repecte pas
a
la lettre les
instructions dans le present manuel risque
de declencher un incendie ou une explo-
sion entrainant des dommages materiels, des
lesions corporelles ou la perte de vies
humanines.
POUR VOTRE SECURITE:
•
Ne pas entreposer ni utiliser d'essence ni
d'autre vapeurs ou liquides inflammables
dans le voisinage de cet appareil ou de
tout autre appareil.
QUE FAIRE SI VOUS SENTEZ UNE
ODEUR DE GAZ:
• Fermer le gaz alimetation.
• Ne pas tenter d'allumer d'appareil.
• Ne touchez
a
aucun interrupteur. Ne pas vous
servir des telephones se trouvant dans le
bariment ou vous trouvez.
• Evacuez la piece, le batiment ou la zone.
Appelez immediatement votre fournisseur de gaz
depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoil)dre le fournisseur de
gaz, appelez le service dos incendies.
L'installation et service doit etre execute
par un qualifie installer, agence de service
ou le fournisseur de gaz.
200·3061n/1000
Need help?
Do you have a question about the RDV40 and is the answer not in the manual?
Questions and answers
How to replace igniter
To replace the igniter on a Vermont Castings RDV40, follow these steps:
1. Turn off the gas supply: Make sure the external gas shutoff is in the OFF position.
2. Remove the glass panel: This is necessary before doing any gas control service work.
3. Access the igniter: Locate the Piezo igniter and electrode near the pilot assembly.
4. Check connections: Ensure the electrode wire is properly connected. If there is no spark at the electrode when pressing the igniter button, the igniter may be defective.
5. Replace the igniter: If defective, remove the old igniter and install a new Piezo Igniter Replacement Kit (part #20000062).
6. Check electrode alignment: The gap between the electrode and pilot should be 1/8 inch for a strong spark.
7. Reassemble and test: Reinstall the glass panel, turn the gas back on, and test the igniter function.
This answer is automatically generated