Page 2
Version of the Operation and Maintenance Manual: EN Edition 4 / 2023-12-05 MyWam sp. z o.o. reserves the right to make technical and commercial changes to the contents of the Operation and Maintenance Manual without prior notice. Each change will be identified by the date of the last update of the manual.
D e l f i E d i t i o n 4 / 2 0 2 3 - 1 2 - 0 5 Table of contents The purpose of the Delfi bath lounger ......................4 ▪ Security .................................. 4 Important safety tips and rules ........................
1. Purpose of the bath lounger Delfi Delfi bath lounger is a class I medical device. It is designed for use in the bath or shower. The primary task of the Delfi bath lounger is to allow the caregiver to freely perform bathing/hygiene activities on the user placed on it, with proper protection and in the optimal position for the user.
4. Leg stabilization straps 5. Perforated upholstery 6. Configuration and use All adjustments of the Delfi bath lounger are made by means of joints. Adjustable recliner ⮚ The angle of the headrest is adjusted using the buttons shown in Figure 1.
Page 6
D e l f i E d i t i o n 4 / 2 0 2 3 - 1 2 - 0 5 Fig. 1 Page | 6...
D e l f i E d i t i o n 4 / 2 0 2 3 - 1 2 - 0 5 Note: Before installing the head stabilizing headrest, select the appropriate height, then using Velcro straps fasten it to the back of the backrest.
Note that the stabilizing belts and tensioning Velcro do not have regular lines (they do not overlap). They arrange themselves depending on the tension of the material and the weight of the user. 7. Technical specifications of the Delfi bath lounger deckchair length 136.8 - 148.8 cm...
Seller). Read the entire manual carefully before using it. No tools are required to assemble and disassemble the Delfi bath lounger. An 8mm wrench is required to adjust the height of the backrest and the depth of the seat.
Class I Medical Device in accordance with the Regulation of the European Parliament and of the Council (EU) 2017/745 of April 5, 2017 on medical devices. The manufacturer has issued an appropriate declaration of conformity for the product, which can be found at www.mywam.eu Page | 10...
E d i t i o n 4 / 2 0 2 3 - 1 2 - 0 5 17. List of authorized service points POLAND MyWam Ltd. 91 Wiosny Ludów Street, 40-373 Katowice, Poland phone: +48 32 733 11 31 website: www.mywam.eu email address: serwis@mywam.eu Page | 11...
D e l f i E d i t i o n 4 / 2 0 2 3 - 1 2 - 0 5 18. Warranty Card Series and number:......... Purchase date: ......- ......- ......Seller's stamp and signature: .......................................
Need help?
Do you have a question about the Delfi and is the answer not in the manual?
Questions and answers