2024/03/282024/03/28 技術本部Page 13/28/2024NO. Doc. no.IZ*-OMQ0001-A PRODUCT NAME Intermittent control timer MODEL / Series / Product Number IZE110-X238...
2024/03/282024/03/28 技術本部Page 33/28/2024NO. Doc. no.IZ*-OMQ0001-A Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or “Danger.” They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC) , and other safety regulations.
Page 4
2024/03/282024/03/28 技術本部Page 43/28/2024NO. Doc. no.IZ*-OMQ0001-A Safety Instructions Caution We develop, design, and manufacture our products to be used for automatic control equipment, and provide them for peaceful use in manufacturing industries. Use in non-manufacturing industries is not covered. Products we manufacture and sell cannot be used for the purpose of transactions or certification specified in the Measurement Act.
Page 5
2024/03/282024/03/28 技術本部Page 53/28/2024NO. Doc. no.IZ*-OMQ0001-A ■Explanation of Symbols Sy mb o l Definition Things you must not do Actual instructions are provided as a drawing or sentence close to this mark. Things you must do Actual instructions are provided as a drawing or sentence close to this mark. ■...
2024/03/282024/03/28 技術本部Page 63/28/2024NO. Doc. no.IZ*-OMQ0001-A ■ Handling Precautions *Product specifications Use the UL-certified products below for combined direct current power supply. (1) Limited voltage current circuit in accordance with UL 508. A circuit which power is supplied by secondary coil of a insulated transformer that meets the following conditions - Maximum voltage (No load): 30Vrms (42.4V peak) or less - Maximum current:...
2024/03/282024/03/28 技術本部Page 73/28/2024NO. Doc. no.IZ*-OMQ0001-A 1. Summary of product parts [ Display ] LED display LCD: Displays the current count value and set values. Green LED Red LED Green LED: LED is ON when the frequency or ON time is set, or valve is operating (confirmed by the count display.) Red LED: LED is ON during duty ratio setting or OFF time setting.
2024/03/282024/03/28 技術本部Page 83/28/2024NO. Doc. no.IZ*-OMQ0001-A 4. Operation (1) Connect terminal No.5 to 24 VDC, terminal No.7 to GND, and terminal No. 1 and 2 to the valve. (2) When terminal No.8 (trigger) is connected to GND, the valve operates for the time previously set by the timer.
Page 9
2024/03/282024/03/28 技術本部Page 93/28/2024NO. Doc. no.IZ*-OMQ0001-A Example 3) Trigger one shot input mode: the trigger starts, and the timer stops, the valve operation. Note 1 [Trigger] [Valve operation] ① ① "Duty ratio" time ② ③ ② "Frequency" cycle ④ ③ ON time ⑤...
2024/03/282024/03/28 技術本部Page 103/28/2024NO. Doc. no.IZ*-OMQ0001-A 5. Mode Setting 5-1 Basic setting mode Press the SET button to select each basic setting item. Press the △ or ▽ button to change the set value in each setting mode. Press the SET button to update the value and complete the setting. *: Press the SET button in each setting mode for 2 seconds or longer to return to normal mode.
2024/03/282024/03/28 技術本部Page 113/28/2024NO. Doc. no.IZ*-OMQ0001-A 6. Definitions and terminology 6-1 Basic setting mode Item Display Set range Description The timer is displayed, with the remaining time for the valve operation counting backwards. Normal operation When the timer countdown ends, and the trigger has not been input, zero will ―...
2024/03/282024/03/28 技術本部Page 123/28/2024NO. Doc. no.IZ*-OMQ0001-A 6-2 Detailed setting mode Setting Item Display Description display Select the specification of the connected valve. (Normally closed) The default is normally closed (nC). Valve selection *: The mode of the output signal is determined according to the selected valve specification.
2024/03/282024/03/28 技術本部Page 133/28/2024NO. Doc. no.IZ*-OMQ0001-A 7. Specifications Power supply voltage 24 VDC +/-10% (with reverse connection protection) Current consumption 50 mA or less (product alone) Connected valve DC24 V 4 W or less Maximum load current 80 mA Max.applied voltage 30 V OUT PUT Residual voltage...
2024/03/282024/03/28 技術本部Page 143/28/2024NO. Doc. no.IZ*-OMQ0001-A 7-2. Error Indication Item Display Description Countermeasures valve supply load Over current current has exceeded 160 Turn the power off and remove the Error 1 cause of the over current. Then supply switch output load Over current the power again.