Trademarks Windows is a registered trademark of the Microsoft Corporation. All other prduct names are trademarks or registered trademarks ofthe respective owners. BA-DKCO2-LOG Data Logger Rev.08/21 V 1.0...
1x USB cable (USB-A to USB-C) • 1x table stand • InfraLog Basic software Downloadable at www.driesen-kern.com/infralog Other options may also include: • Certificate of calibration • Concealed wall holder • InfraLog Light/Enhanced license (serial key) BA-DKCO2-LOG Data Logger Rev.08/21 V 1.0...
InfraLog for Windows. Refer to chap- ter 4.15 for more information regarding spreadsheets. ► In order to upgrade your InfraLog version, when prompted, enter the serial number and license keys (key1/key2) from the included certificate. Done. BA-DKCO2-LOG Data Logger Rev.08/21 V 1.0...
User Manual Driesen + Kern GmbH General Informationen The DKCO2-Log is a data logger for recording and indicating CO2, ambient tempera- ture, relative humidity and barometric pressure readings. BA-DKCO2-LOG Data Logger Rev.08/21 V 1.0...
1 Minute ca. 6 Months Manual Configuration The most importent features of the DKCO2-Log can be used with the SET button at the top. Pressing it will be accompanied by the status LED flashing up. Note: Before its first use the logger needs to be connected to InfraLog in order for the automatic time synchronisation to take effect.
2 seconds to return to the main menu. If you want to start the logger now, confirm <Yes> by pressing the SET button for 10 seconds, during which both the blue status LED at the bottom and the green Indicator BA-DKCO2-LOG Data Logger Rev.08/21 V 1.0...
Indicator LED will flash simultaneously, indicating that the command is being ex- ecuted, until they stop and the amber light flashes. Press SET shortly and the DKCO2-Log reads Display off, now press SET for 2 sec- onds again to finally turn the LCD off.
Please note that this drastically reduces battery life! 3.2.7.2 Device Setup – CO2 Indicator The DKCO2-Log uses its LEDs in a traffic light style to indicate the CO2 levels. Refer to chapter 6 for more information. If the LED indication is not needed, it can be disabled.
100% Nitrogen level is achieved. A calibration using Nitrogen should only be performed by trained personel and after consultation with Drisen + Kern. 3.2.8 DisplayOff Manually turn off the display to save energy. Not permanent. BA-DKCO2-LOG Data Logger Rev.08/21 V 1.0...
You will be asked to install the USB driver. Click Install and wait until installation is complete After drivers have successfully been installed you can start InfraLog. Main Menu The main window of InfraLog offers a range of important items. BA-DKCO2-LOG Data Logger Rev.08/21 V 1.0...
Select another value to have shorter numeric values. Choose between TAB and Semicolon as the Column Delimiter. Choose from a range of style templates in the Porgram interface tab how InfraLog looks. BA-DKCO2-LOG Data Logger Rev.08/21 V 1.0...
User Manual Driesen + Kern GmbH 4.2.2 Search Devices Connect the DKCO2-Log to your computer with the included USB cable. When connecting a logger for the first time, Windows automatically installs USB express drivers to identify the device. Upon completion windows shows the notification “The device is now ready to use.“...
Memory [%] shows the percentage of used memory. Actual time shows the current internal time. Internal clock is automatically synchro- nised with your computer (option is enabled by default). Please make sure that your computer’s date and time are set correctly. BA-DKCO2-LOG Data Logger Rev.08/21 V 1.0...
While connected via USB the USB port warms up which causes the internal tempera- ture sensors to show temperatures 2°C higher than what should be expected. After unplugging the DKCO2-Log it can take from several minutes up to an hour, de- pending on ambient conditions, to reach specified accuracy again.
If you select immediately the logger will start log- ging at the next full minute. Um die Einstellungen zu ändern, klicken Sie mit der linken Maustaste rechts am Bild- rand auf das Symbol neben der aktuellen Einstellung. BA-DKCO2-LOG Data Logger Rev.08/21 V 1.0...
Page 18
Enter a Description of up to 46 characters to specify the measurement location or pur- pose. After every setting has been configured, click on Start Logger now. After a few seconds InfraLog notifies you that the logger has been started successfully. Warning: Deleted measurement data cannot be recovered! BA-DKCO2-LOG Data Logger Rev.08/21 V 1.0...
InfraLog.exe [SPACE] /convert [SPACE] „complete path to *.bin“ The *.asc files will be created and saved in the same folder. GUI will not be visible. Successfull completion of conversion will be indicated by return value 0. BA-DKCO2-LOG Data Logger Rev.08/21 V 1.0...
Enter a Logger Name in this tab for easier identification of measured data. Note: Logger name may include characters 'A-Z', 'a-z', '0-9', '_' or '-'. Blank may be included but not at the beginning or the end of the name BA-DKCO2-LOG Data Logger Rev.08/21 V 1.0...
Simply import the *.bin file and select the desired calculated values before the file is being converted into ASCII format. BA-DKCO2-LOG Data Logger Rev.08/21 V 1.0...
Driesen + Kern. Change yellow and red LED thresholds in section Activate indicator lights. Enable/disable the audible alarm (buzzer) – it triggers upon reaching the threshold of the red LED. BA-DKCO2-LOG Data Logger Rev.08/21 V 1.0...
Driesen + Kern GmbH 4.4.3 Setting up an Alarm The DKCO2-Log two types of alarm. While the settings for the indicating LEDs and the buzzer are exclusively for CO2, the internal alarm feature can also be used for parame- ters humidity, temperature and barometric pressure.
Display Logged Data as a Table Click on the icon depicted on the left or go to Data/Table. You will be prompted to select an ASCII file. Readings will be opened with the program selected in Preferences/Program. BA-DKCO2-LOG Data Logger Rev.08/21 V 1.0...
Either sensor or cable is defective. After inserting the batteries, the display lights up shortly but then turns off and pressing the button has no effect. LCD has been permanently disabled. Reactivate LCD as described in chapter 3.2.7.1. BA-DKCO2-LOG Data Logger Rev.08/21 V 1.0...
► Service & Support ► Support The forms can be filled out on your computer and quickly emailed back to us at sup- port@driesen-kern.de – or just include the filled-out form in your calibration or repair delivery. BA-DKCO2-LOG Data Logger Rev.08/21 V 1.0...
Flashes red 0.5s every 15 seconds System check OK Running lights after battery change The DKCO2-Log’s traffic light style LEDs indicate indoor air quality. They are located below the display. Their default thresholds are: Green LED Amber LED Red LED CO2 Concentraion <1000 ppm...
The logger requires only a minimum of maintenance. If the device will be unused for longer periods, please remove the batteries. The DKCO2-Log’s sensors are precise and long-term stable, which means they are mostly unaffected by drift. Yet, contaminants can still interfere with the humidity sensor measurements.
Certificate of Conformity Driesen + Kern GmbH Physikalisch-Technische-Messgeräte Product: Data Logger DKCO2-Log This ist o certify that above products are calibrated using dediacted equipment which is calibrated by comparison against natural stand- ards, natural physical constants, consensus standards, or by ratio type measurements using self-calibration techniques.
Need help?
Do you have a question about the DKCO2-Log and is the answer not in the manual?
Questions and answers