Advertisement

Quick Links

U S E R M A N U A L
U S E R M A N U A L
Product name
P.R.O. Matt ®
Plus
to go here
Product description to go here
To avoid injury, read user manual
prior to use.
®
P.R.O Matt Plus
enablelifecare.com.au

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the P.R.O. Matt Plus and is the answer not in the manual?

Questions and answers

Summary of Contents for Enable Lifecare P.R.O. Matt Plus

  • Page 1 U S E R M A N U A L U S E R M A N U A L Product name P.R.O. Matt ® Plus to go here To avoid injury, read user manual Product description to go here prior to use.
  • Page 2: Important Precautions

    Important Precautions Important Notice: The equipment must be installedand operated in the manner for which it was intended. Facility staff/user is responsible for reading and understanding the product user manual and contacting Joerns Healthcare if anything in this manual is unclear. Joerns will not be held responsible for any injuries resulting from failure to comply with the instructions and precautions in this manual.
  • Page 3 5. Never drop or insert any object into any opening or hose. 6. Do not spill food or liquids onto the control unit. If a spill does occur, turn off the unit, disconnect it from its power supply and allow at least 24 hours for drying. 7.
  • Page 4: Table Of Contents

    Table of Contents Important Precautions.............................. 2 Introduction................................. 5 Pressure Redistribution Shear and Friction Reduction Indications for Use..............................6 Pressure Redistribution Pain Management Features..................................6 Mattress Features ES Therapy Control Unit Features ES2 Therapy Control Unit Features CBC Therapy Control Unit Features Grounding Instructions.............................
  • Page 5: Introduction

    NOT to be used when such gaps are present. See “Important Precautions” section of this manual. The P.R.O. Matt Plus has a safe working load (SWL) of 500 lbs. In the non-powered mode, the P.R.O. Matt Plus design allows healthcare providers to provide optimal interface pressures through controlled air cell inflation for at-risk patients and treatment for Stages I and II pressure ulcers.
  • Page 6: Indications For Use

    The use of the P.R.O. Matt Plus for these patients should be considered on an individual basis and discussed with the attending physician.
  • Page 7: Es2 Therapy Control Unit Features

    • Three alternating pressure cycle times: 5, 10, and 15 minutes • Five Comfort Adjust settings provide the ability to increase or decrease the general firmness of the P.R.O. Matt Plus mattress • Quick disconnect hoses allow easy setup and CPR release • Compact lightweight control unit is quiet and energy efficient...
  • Page 8: Cbc Therapy Control Unit Features

    Joerns CBC Therapy Control Unit Features Grounding Instructions Setup • Therapy modes of operation: Alternate and Static powered Warning: Use a properly grounded, three-prong, 120V Warning: For important precau • Alternate feature alternates the air pressure in adjacent cells throughout the mattress AC outlet for this product.
  • Page 9: Setup

    Setup WARNING: For important precautions, see page two. CAUTION: Do not place the control unit on the floor. Position the power cord to keep personnel from tripping over it. 1. Remove the existing mattress from the bed. 2. Place the P.R.O. Matt® Plus mattress with the logo at the foot end of the bed. 3.
  • Page 10: Powered Modes

    The P.R.O. Matt Plus converts to an alternating pressure redistribution system when connected to a control unit. By adding the optional ES2 control unit, the P.R.O. Matt Plus has three pressure redistribution modes: Autofirm, Therapy, and Alternate. By adding the optional CBC control unit, the t Surfaces P.R.O.
  • Page 11: Cbc Control Unit

    • Alternating: The pressure automatically alternates between adjacent therapy cells throughout the length of the P.R.O. Matt Plus mattress on a ten minute cycle. Power The green Power switch is used to turn the CBC control unit on and off. When in the on position, the Power light is illuminated.
  • Page 12: Transport

    Power Failure In case of an extended power failure, the P.R.O. Matt Plus mattress system should be disconnected from the control unit. The patient can be left on the mattress which will force out air from the internal alternating cells. In the non-powered state, the mattress will continue to function as a dynamic pressure redistribution mattress replacement system.
  • Page 13: Troubleshooting

    Elevating Patient into Sitting Position The special properties of the P.R.O. Matt Plus reduce the opportunity for shear and friction that may occur when raising the back section of other beds systems. As with any surface, sliding can be expected;...
  • Page 14: Contractures

    Contractures Contractures and foot drop are a concern for all bedridden and immobilized patients. Physical therapy and any prescribed exercises may be performed on the P.R.O. Matt® Plus as is done on any traditional hospital bed. Incontinence Moisture against the skin surface leads to maceration, or softening of the tissues. To prevent maceration, we recommend you use an incontinence barrier pad to absorb the excess moisture.
  • Page 15: General Cleaning

    General Cleaning If there is no visible soilage with possible body fluids, we recommend that you clean the mattress system with a mild detergent and warm water. If disinfection is desired, you may use a combination cleanser/disinfectant as explained in “Disinfecting”. 1.
  • Page 16: Maintenance

    Maintenance WARNING: Only authorized personnel trained by Joerns Healthcare should perform preventative maintenance. Preventative maintenance performed by unauthorized personnel could result in personal injury and/or equipment damage. Any maintenance done without Joerns Healthcare’s authorization will void any warranties on this product.
  • Page 17: System Specifications

    System Specifications Weight Environmental Conditions Mattress..........24.5 lbs. (11 Kg) Operating Conditions: Maximum weight capacity*:..500 lbs. (227 Kg) Ambient temperature: +10°C to +40°C ES2 Control Unit......7 lbs. (3 Kg) Relative humidity: Non-condensing CBC Control Unit......4.2 lbs. (1.9 Kg) Storage And Shipping Conditions: Ambient temperature: 10ºC to +40ºC Dimensions: Relative humidity: Non-condensing...
  • Page 18: Warranty

    This is normal and is not included in this or any other warranty applicable to this product. The P.R.O. Matt Plus warranty is void if the manufacturer’s tag is removed from the mattress.
  • Page 19 But we do more than just provide products. We give the knowledge and support to help our customers grow their business and deliver better life care. ENABLE LIFECARE PTY LTD T 1300 370 370 enablelifecare.com.au ® P.R.O Matt Plus...

Table of Contents