Download Print this page

SK SATO PC-9410 Instruction Manual

Waterproof digital thermometer

Advertisement

Quick Links

Instruction Manual of
Waterproof Digital Thermometer Model PC-9410
This product is designed to measure temperature. Do not use it for other purposes.
Read this manual thoroughly before use, and keep it for future reference.
Important Notices
Beware of Explosion
PC-9410 is not explosion-proof. Never use it in an atmosphere with flammable gases.
Cautions
To use PC-9410 properly, follow the instructions below.
Do not use the device as a clinical thermometer.
Do not drop or give a shock to the device, as it is a sensitive instrument.
Do not disassemble, customize, or insert improper batteries to the device.
Handle the sensing part carefully to not to hurt yourself with its sharp edge.
Do not press or bend the sensing part.
Do not pull, bend, twist, or bind the sensor cable.
Do not measure temperature out of the measurable range.
Do not use the device in an environment with electrical noise or with your hands
touching the sensor cable. Otherwise, the display may become unstable or the
measurement error may increase.
Do not use the device under direct sunlight or aside a heat source, or it may lead
to a deformation or malfunction.
Do not leave the device in a place like an automobile on a fine summer day, or the
extreme heat may damage it.
Wet hands or water splashes do not affect the function of the device. However, do
not immerse the parts other than the sensor in liquids.
To sink the sensor underwater, make sure that the temperature lies between 10
and 40°C, and the depth is less than 1 m.
PC-9410 can be fully rinsed with tap water. However, do not leave it underwater.
Do not wash or wipe the device with alcohol, thinner, or other organic solvents.
If the device becomes dirty, wipe it with a tightly-wrung towel dipped in warm water
with neutral detergent.
After washing, wipe out the water with a dry cloth completely. Do not put the device
in a dryer.
Because sodium hypochlorite corrodes metals, do not put it on the sensing part. If
the device is contaminated by sodium hypochlorite, rinse and wipe it out completely.
For stable long-life use it is recommended to check the measured reading
comparing with other correct thermometers. We offer traceable calibration service
to achieve it.
For repair or calibration, or if the device is broken before use, contact us or a retailer
from which you have purchased.
Cautions Related to Magnets
As PC-9410 contains magnets, do not place it near the followings:
chests of people with pacemakers or other implanted cardiac devices
electronic devices
materials vulnerable to magnetic fields such as magnetic cards
Names of Sections
Hook
Display
Max/min key
On/off key
Hold key
Sensor cable
Two magnets embedded
Sensor cable
Battery lid
Sensing part

Advertisement

loading
Need help?

Need help?

Do you have a question about the PC-9410 and is the answer not in the manual?

Questions and answers

Summary of Contents for SK SATO PC-9410

  • Page 1 PC-9410 can be fully rinsed with tap water. However, do not leave it underwater.  Instruction Manual of Do not wash or wipe the device with alcohol, thinner, or other organic solvents.  If the device becomes dirty, wipe it with a tightly-wrung towel dipped in warm water Waterproof Digital Thermometer Model PC-9410 ...
  • Page 2 If the battery slides toward internal magnets, push the battery with the lid to stop sensing part in a target for more than 60 mm. sliding. To keep the body of PC-9410 from heat, do not measure temperature higher than  50°C continuously for 2 minutes.
  • Page 3 Auto Power Off Power CR2032 battery x 1 (3VDC) PC-9410 shuts down its power automatically after 60 minutes of operation, to reduce Battery life 10 months if used 60 minutes a day the loss of battery. This function cannot be disabled.