Summary of Contents for ALGE-Timing Teledata TED-TX10
Page 1
Version-E111206 Teledata TED-TX10 and TED-RX10 Manual...
Page 2
We hereby declare that the following product complies with the below stated standards. All components used by us are CE certified by their producer and are not modified by ALGE- TIMING GmbH. ALGE-TIMING GmbH Rotkreuzstrasse 39 A-6890 Lustenau declare in sole responsibility that the radio receiver...
Page 3
ALGE-TIMING GmbH Rotkreuzstrasse 39 A-6890 Lustenau declare in sole responsibility that the radio transmitter Teledata TED-TX10 complies with the following standards/normative documents and in case of intended use complies with the basic requirements of R&TTE 1999/5/EC: Telecommunication (TC)terminal device Radio equiment...
Page 4
Important Information General Before using your ALGE-TIMING device read the complete manual carefully. It is part of the device and contains important information about installation, safety and its intended use. This manual cannot cov- er all conceivable applications. For further information or in case of problems that are mentioned not at all or not sufficiently detailed, please contact your ALGE-TIMING representative.
Page 5
Manual TED-TX/RX10 Transmitter Antenna Green holder with Velcro fastener Light emitting diode (LED) Banana socket yellow: data input Banana socket green: signal input Banana socket black: common mass DIN socket: data and signal input and external supply 3/8“ thread for tripod fastening Code switch (16 positions) Device button Device switch...
Manual TED-TX/RX10 1 General The TED-TX10 does not have to be authorized in EC and EFTA countries. Nevertheless, we recommend to check the legal conditions of the country to avoid problems with local and/or new laws. For countries outside Europe, please check in the corresponding country if the device may be used.
Manual TED-TX/RX10 Batteries In case the device is not in use for a long period, we recommend to remove the batteries from the battery compartment. Batteries can be perilous when swallowed. Keep out of reach of children. Do not throw into open fire.
Manual TED-TX/RX10 2.3.2 Operating period The below stated measurements apply to alkaline batteries at room temperature (25 ° C). Mind that the capacity of the batteries is extremely reduced at low temperatures (at –20° C only about 20 % capacity). TED-TX10 without photocell 1 impulse per minute...
Manual TED-TX/RX10 2.5.1 Direct Supply The TED can be supplied by the ALGE power supply units. 2.5.2 Supply by timing device In the operation mode impulse transmission the TED-RX can be powered by the power sup- ply unit of the timing device. Cable 004-05 is required for connection between TED-RX and timing device.
Manual TED-TX/RX10 Installation There are several possibilities to install or fit the TED. Good: Bad: Fastening with Velcro The TED should never be fastener. critical placed directly on the floor. To situations always mount much operation range is lost. overhead. Bad: The antenna always has to point upward.
Manual TED-TX/RX10 Switching on Normal operation Switch on device switch (11) TED works in operation mode „impulse transmission“ LED blinks Test Mode Press device button (10) Device switch (11) at „ON“, LED must blink Release device button Test mode switches automatically off after one minute, immediate switch off with device button (10) Data transmission ALGE 1 sec.
Manual TED-TX/RX10 Selecting the operations modes Switch Signal Mode Data Mode Position 0: data transmission ALGE 1 second Position 1: data for display board ALGE 1 sec. Position 2: no function Position 0 to 9 Position 3: data transmission 2400 baud Code switch (12) for selecting Position 4: data transmission 4800 baud...
Manual TED-TX/RX10 Field intensity test for location search The field intensity test can only be executed in the operation mode „impulse transmission“. For problem-free work with the TED, an optimal location has to be found. Activate field intensity: Switch on TED-TX Press device button (10) Fasten TED in the height (page 11) Switch on TED-RX...
Page 15
Manual TED-TX/RX10 Bounce protection The TED-TX is provided with a bounce protection. The bounce pro- tection prevents double impulses of a bouncing switch contact. Debounc- ing time is 50 ms. Bouncing at the beginning of the impulse Bouncing at the end of the impulse Impulse duration plus bounc- ing duration...
Manual TED-TX/RX10 Impulse transmission from a startgate Impulse transmission from a photocell Impulse transmission from a photocell with adapter 129-06 With the adapter 129-06 it can be set if it is a start or stop impulse. This is of advantage if only one photocell is used for a circuit.
Manual TED-TX/RX10 Impulse transmission with more than two timing channels For this, the adapter RX-C10 is required. In connection with TDC8000/8001 and Timer S4 it is possible to transmit up to 10 timing channels. However, several TED-TX have to be used for it.
Manual TED-TX/RX10 Impulse transmission several timing channels with Timy and cable 207-10 The cable 207-10 works only in connection with the Timy. Only start cables (000-xx or 002- xx) may be used. When using a stop cable no impulse is transmitted and an error message is printed.
Manual TED-TX/RX10 Data repetition: In case the data does not reach the receiver, the data can be repeated at the transmitter. The latest dataset is always stored at the TED-TX. Press device button (10) at TED-TX Press push-button connected to green and black banana socket of TED-TX Data transmission 1 second Setting:...
Manual TED-TX/RX10 Data transmission of start time from a synchronized Timer S4 to another Timer S4: Set program 3 on Timer S4 at start and enter daytime Press yellow and red button at the same time The display of Timer S4 shows „HP 0:00.00“ Enter hours with red button Enter minutes with yellow button Set program 0 on Timer S4 at finish and enter daytime...
Manual TED-TX/RX10 Display transmission 1 second Setting: Code switch (12) of TED-TX and RX on position 1 Only for data with ALGE protocol. One data transmission per second is effected from TED-TX to RX. Each dataset is only sent once. Every dataset has a check sum. If this is correct, the incoming data is output.
Manual TED-TX/RX10 Data transmission direct Setting: Code switch (12) of TED-TX and RX on position 6 Adapter 119—5 must be connected to TED-TX. One dataset must be transmitted so that the TED switches to direct mode (LED switches from blinking to permanent glow). Every dataset is transmitted with a baud rate of 2400 to 4800 baud.
Manual TED-TX/RX10 6 Technical data Operating frequency: Standard 10mW 433 MHz band, fix frequency set by pro- ducer Emitting power: TED-TX10: 10mW Operating range: TED-TX10: approx. 1.5 km Antenna: fix screwed, 0dB Signal input TED-TX: active low, min. 10 ms, bounce time ca. 50 ms Signal output TED-RX: active low, 100 ms Supply:...