USER GUIDE UNDER SINK REVERSE OSMOSIS SYSTEM MQ4 & MQ5 INSTALLATION INSTRUCTIONS WM 22780 WMTS 103 For the correct operation and maintenance of this product, it is essential to observe the manufacturer’s instructions. Do not use with water that is microbiologically unsafe.
Caution: Do not use with water that is microbiologically unsafe or with water of unknown quality without adequate disinfection before or after the system. Operations The MQ4 & MQ5 systems are designed to run economically for many years dependent on the initial installation and periodical maintenance. Product Specifications...
Your Reverse Osmosis System has been tested to ensure it will operate correctly. The following periodic maintenance is recommended so your system will provide years of trouble-free service. Cartridge Filter Service Life Pre-filter (5 micron PP sediment MT-05) Every three months Pre-filter (Coconut shell Activated carbon MT- Every six months...
Installation diagram Operation regulation 1. With everything connected, turn on the water check for leaks. 2. Make sure the storage tank shut off valve is “OFF”. Open the sink top faucet. 3. Within a few minutes (up to 15) the water will start to run from the faucet slowly. 4.
OK and then turn it on. Turn off both the water valve and power supply. Call Micron Water filters 1300 613 878. Water is leaking Fittings are loose on the Turn off the water valve, power booster pump [if model has switch and power supply.
Micro-computer instructions Light’s blinking when it’s time to replace the 1 filter, 2 filter, 3 filter, 4 filter, or 5 filter This button will let you know when it’s time to replace filter and TDS valve • This button is to reset the time after replacing a new filter or RO membrane •...
a) Black: Low pressure switch b) Blue: High pressure switch c) Red: Inlet solenoid valve. Notice – remove red wire when using four shut-off valves d) Yellow: Flush solenoid valve e) Red/Black (thin): Pump DC24V f) Red/Black (thick): Electronic adapter DC24V 1.2A g) TDS probe: connect after check value (pure water) Operation a) When closing (without) feed water, low pressure switch will be delayed for ten seconds, then...
factory original setting is which means the 1 filters replacement reminder alarm is set every three months. b) Press SET key again, then proceed by entering the 2 setting mode. The LED will show and the light “2” will start to blink. The original setting is which means the 2 filters replacement reminder alarm is set every six months.
You must submit details and proof of your expense claim to Micron Water Filters for its consideration. This warranty is given in lieu of all other express or implied warranties and Micron Water Filters and the manufacturer shall in no circumstance be held liable for damages consequential or otherwise or delays caused or faulty manufacturing.
Page 13
Sediment & dissolved impurities VOC's & chemicals Chlorine & fluoride Bacteria & viruses Heavy metal * 98% removal of impurities Contact us | www.micronwaterfilters.com.au Micron Water Filters U4 86 Forsyth Street O’Connor WA 6163 Ph: 1300 613 878...