Advertisement

InstallatIon and operatIon manual
Solibro Solar Modules SL2 and SL2-F
from the Generation 1.5

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Solibro SL2 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Hanergy Solibro SL2 Series

  • Page 1 InstallatIon and operatIon manual Solibro Solar Modules SL2 and SL2-F from the Generation 1.5...
  • Page 2: Table Of Contents

    IntroductIon plannIng Technical data Requirements Mounting variants Electrical layout InstallatIon Safety and transport Preparation for installation Module installation electrIcal connectIon Safety Safety during electrical installation work Module connection After the installation groundIng 5.1 Specifications for functional grounding Functional grounding Potential equalization frame cleanIng and maIntenance Faults recYclIng addItIonal InFormatIon...
  • Page 3: Introduction

    1 IntroductIon solar modules from solibro gmbH (referred to below as solibro) V alid country-specific laws, regulations and requirements for ƒ allow you to directly transform the unlimited energy provided by planning, installation and operation of solar power plants and the sun into environmentally friendly electrical energy. to ensure working on the roof.
  • Page 4: Planning

    2 plannIng 2.1 tecHnIcal data product lIne sl2-F type unframed framed area [m²] 0.94 0.95 Weight [kg] 16.5 18.1 max. system voltage V 1000 1000 max. reverse current loading capability l Junction box Protection class iP 65 with bypass diode Protection class iP 65 with bypass diode connector Multi-contact Mc4 (protected against accidental contact, protected against polarity reversal, uv- and...
  • Page 5: Requirements

    2 plannIng requirements on the module orientation 2.2 requIrements installation in landscape or portrait possible. ƒ Installation location ƒ installation with the junction box in the top section of the module. The connection cables hang down. comply with the following notes on the installation location: The optimal inclination angle of the module depends on the The modules are tested in accordance with iEc 61646, 61730 ƒ...
  • Page 6 2 plannIng requirements on the clamping system for unframed modules requirements on the clamping system for framed modules only clamp systems approved by Solibro may be installed. The list When using framed Solibro products, it is important to ensure of all approved clamps is available at that there is no potential difference between frame and ground.
  • Page 7: Mounting Variants

    2 plannIng 2.3 mountIng optIons Approved clamp areas and mounting options for the solar modules (top view). Dimensions in mm. The specified dimensions refer to the clearance between the module edge and the middle of the clamp. The illustrated mounting variants apply for installation in portrait and landscape format. unframed modules clamping at long side, clamping at long side,...
  • Page 8: Electrical Layout

    2 plannIng 2.4 electrIcal laYout parallel connection ¼ only connect modules of the same type and power class. requirements on the system Do not exceed the maximum permissible reverse current as ¼ You can find the detailed electrical parameters in the product given in the respective data sheet.
  • Page 9: Installation

    3 InstallatIon 3.1 saFetY and transport ¼ Ensure that the personnel are familiar and ƒ danger! danger due to electric shock! comply with the accident prevention and safety Do not install damaged modules. ¼ regulations. Report any damage to your dealer immediately. ¼...
  • Page 10 3 InstallatIon ƒ note! damage to the modules! ƒ note! damage to the modules! use glass suction cups to remove and trans- Do not put unframed modules down on their ¼ ¼ port modules. edges without protection. ¼ carry the modules vertically. note! damage to the modules! note! damage to the modules! ƒ...
  • Page 11: Preparation For Installation

    3 InstallatIon 3.2 preparatIon For InstallatIon danger! danger due to electric shock! note! damage to the modules! ƒ ƒ  cordon off the installation area. ¼ The transport protection should not be ¼ ¼ Keep children and unauthorised persons away removed until immediately before or after the from the solar system.
  • Page 12: Module Installation

    3 InstallatIon 3.3 module InstallatIon Installing unframed modules Please note the requirements on the clamping system outli- ¼ Position the modules plane. ¼ ned in chapter 2. ¼ use anti-slip protection or spacers on the modules. This is particularly important when installing the modules in portrait format.
  • Page 13: Electrical Connection

    4 electrIcal connectIon 4.1 saFetY danger! danger due to electric shock! ƒ danger! never open the junction box. ¼ danger due to electric shock! ¼ Do not remove the bypass diodes. When disconnecting an electric circuit transporting direct current, electric arcs can occur that can result in life-threatening injuries. Do not disconnect the cable and plug while they are energised.
  • Page 14: Safety During Electrical Installation Work

    4 electrIcal connectIon 4.2 saFetY durIng electrIcal InstallatIon Work danger! danger due to electric shock! danger due to electric shock! ƒ ƒ danger! Ensure correct polarity. never disconnect the plugs in energised state. ¼ ¼ switch off the inverter. keep the dc side free with isolators SWITCH danger! danger due to electric shock! cover modules that need to be separated.
  • Page 15: Module Connection

    4 electrIcal connectIon 4.3 module connectIon use solar cables for the connection on the ¼ Ensure that a secure connection is in place ¼ junction box outlet. between the plugs. Plugs engage audibly. ¼ use matching plug systems, which are compat- ¼...
  • Page 16: After The Installation

    4 electrIcal connectIon 4.4 aFter tHe InstallatIon ¼ carry out all necessary safety and functional ¼ Avoid having the connections on a level carry- tests according to the current state of ing water. technology. ¼ integrate the system in the existing lightning ¼...
  • Page 17: Grounding

    5 groundIng 5.1 specIFIcatIons For FunctIonal groundIng only ground the negative pole of the system. ¼ Solibro solar modules must always be protected against negative voltages on the generator poles! ¼ Always connect modules to systems with negative ground. ¼ Follow the usage instructions for negative generator pole grounding provided by the inverter manufacturer.
  • Page 18: Cleaning And Maintenance

    6 cleanIng and maIntenance Solibro solar modules stand for a long useful life and minimal note ! damage to the modules! ƒ maintenance effort and expense. Light soiling is usually washed ¼ Do not clean the module with water if there is a away by rain.
  • Page 19: Faults

    7 Faults 9 addItIonal InFormatIon danger! required information in accordance with Iec-61730: danger due to electric shock! The Solibro modules from the series SL2 and SL2-F are quali- ƒ fied for application class A. ¼ in case of problems or damaged modules (e.g. glass breakage, ƒ...
  • Page 20 SOLIBRO GMBH OT Thalheim, Sonnenallee 32–36 EMAIL service@solibro-solar.com www.solibro-solar.com 06766 Bitterfeld-Wolfen, Germany...

This manual is also suitable for:

Solibro sl2-f seriesSolibro sl2-140 g2.3 uf 140wp

Table of Contents