Observator Instruments OIC-406 Manual

Temperature & humidity sensor

Advertisement

Quick Links

OIC-406
Temperature & Humidity Sensor
Manual
Version 1.2 – April 2024
Author: Observator Instruments

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OIC-406 and is the answer not in the manual?

Questions and answers

Summary of Contents for Observator Instruments OIC-406

  • Page 1 OIC-406 Temperature & Humidity Sensor Manual Version 1.2 – April 2024 Author: Observator Instruments...
  • Page 2 Revisions: (May 2016) First issue (August 2016) Preliminary edition 1.01 (March 2017) First Release (October 2020) Update sensor probe (April 2024) Update EU declaration of Conformity OIC-406 Manual Page 2...
  • Page 3: Table Of Contents

    Commissioning ............................. 8 Basic Node connections ........................9 Device status LED’s ........................10 Specifications ............................11 Specifications OIC-406 probe ....................11 Specifications Meteolink general ....................11 Maximum allowed cable lengths ....................12 Dimensional drawings ......................... 13 XDR messages ........................... 14 EU Declaration of Conformity ......................
  • Page 4 Page intentionally left blank OIC-406 Manual Page 4...
  • Page 5: Introduction

    Due to the integration of the basic node other sensors – like a wind sensor - can be interfaced and the signals will be combined in 1 NMEA stream. This manual is intended for the System integrator, Installer and Commissioner of the Observator OIC-406 temperature and humidity sensor.
  • Page 6: Safety

    2 Safety For correct functioning of Observator OIC-406 it must be installed according installation instructions. Any unused gland should be filled with the include plug when not in use. The OIC-406 probe is a sensitive instrument, store dry. Direct contact with salt water can make the probe unusable for humidity measurement! Remember: instruments are tools.
  • Page 7: Description

    3 Description 3.1 General description Observator Meteolink OIC-406 uses an accurate combined temperature and humidity probe.. The vented anti-radiation shield has been designed to create a natural airflow which contributes to the accuracy of the sensor. The probe signal is converted into a standard NMEA signal by the basic node, which also functions as a junction connection box.
  • Page 8: Installation

    The sensor will start heating first (for humidity measurement) and will not produce data until the first cycle is finished. It can take up to 6 minutes before the OIC-406 produces data at start up or after a power cycle. OIC-406 Manual...
  • Page 9: Basic Node Connections

    9 GND (Supply) 25 0-5VDC_IN_1 10 SUPPLY 11 NMEA1_IN_A 26 GND (Sensor) 12 NMEA1_IN_B 27 SUPPLY 28 0-24mA_IN_1 13 GND (Supply) 14 SUPPLY 29 GND (Sensor) 15 NMEA2_IN_A 30 CMOS_SUPPLY (3.3V) 16 NMEA2_IN_B 31 CMOS_TX 32 CMOS_RX OIC-406 Manual Page 9...
  • Page 10: Device Status Led's

    If you experience difficulties connecting with the device; Check if the LED’s are blinking, Check the wiring of the Tx/Rx or A/B wires; Check the data settings of your COM port. OIC-406 Manual Page 10...
  • Page 11: Specifications

    7 Specifications 7.1 Specifications OIC-406 probe Temperature: Temperature range: -50⁰C..+100⁰C Accuracy: ± 0.1⁰C (10-30 ⁰C) Humidity: Humidity: 0..100%RH Accuracy: ± 0.8 %RH (10-30 ⁰C) Long term drift: <1%RH/annum 7.2 Specifications Meteolink general Basic node SMART node Remarks Voltage 12..24 Vdc 12..24Vdc...
  • Page 12: Maximum Allowed Cable Lengths

    Shielded twisted pair Rain (puls) Shielded twisted pair Shielded twisted pair CMOS Shielded twisted pair Above cable lengths may not be exceeded to comply with EMC regulation. Shield must be connected to transmitting or load side only! OIC-406 Manual Page 12...
  • Page 13: Dimensional Drawings

    8 Dimensional drawings OIC-406 Manual Page 13...
  • Page 14: Xdr Messages

    Calculated baro Runway Level Dewpoint Calculated Dewpoint XDR messages can be send individual or can contain multiple parameter data. Example: $WIXDR,H,52.93,P,,C,16.22,C,*42 (humidity & temperature) Is identical to: $WIXDR,H,52.93,P,*6B (humidity) $WIXDR,C,16.22,C,*79 (temperature) Both ways of ending data are correct. OIC-406 Manual Page 14...
  • Page 15: Eu Declaration Of Conformity

    10 EU Declaration of Conformity OIC-406 Manual Page 15...