Advertisement

Quick Links

GRANULAR FLOW CONTROLLER
Installation Manual Part No: AAP8300-DUAL REV: 1.0
AG-NAV
1-800-99 AGNAV
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Granular Flow Controller and is the answer not in the manual?

Questions and answers

Summary of Contents for AG-NAV Granular Flow Controller

  • Page 1 GRANULAR FLOW CONTROLLER Installation Manual Part No: AAP8300-DUAL REV: 1.0 AG-NAV 1-800-99 AGNAV...
  • Page 2 AG-NAV Inc. AG-NAV Inc. provides this manual “as is”, without warranty of any kind and reserves the right to make improvements and/or changes to the product described in this manual at any time and without notice.
  • Page 3 Barrie, ON L4N8Z5, Canada In the event of a problem that cannot be resolved using the information supplied, please contact AG-NAV. You can also gain assistance through the user’s area on our web page at www.agnav.com. For further assistance, contact the AG-NAV technical support line by telephone, fax, or email. AGNAV customer support personnel will discuss your situation, determine the cause of problem and provide the appropriate technical assistance.
  • Page 4: Table Of Contents

    Table of contents 1: Getting started ....................5 1.1 About Ag-Nav granular flow controller ............5 1.2 Parts list ......................5 1.3 Before installation ..................... 5 2. System overview ....................6 2.1 How the system works ..................6 2.2 Simplified system diagram ................6 2.3 Function of the 2 position auto/manual switch ..........
  • Page 5: 1: Getting Started

    The Ag-Nav Granular Flow Controller works in conjunction with the Isolair 4500 series Broadcaster system to provide even application of granules over the target areas. The Granular Flow Controller consists of one controller box, two granular dispensers and harness. Each granular dispenser has an impeller driven by a covered DC motor with a RPM encoder.
  • Page 6: System Overview

    System overview How the system works The AG-NAV Granular Flow Control system is designed to ensure a steady distribution of dry granular material by automatically adjusting the dispersal rate when the aircraft speed changes. The DC motors individually control the impeller RPM with feedback from the high precision Optical encoders.
  • Page 7: Function Of The 2 Position Auto/Manual Switch

    Function of the 2-position auto/manual switch The granular Flow controller includes a 2-position toggle switch used to perform the following functions: Automatic: The automatic system mode uses the Guia or Platinum guidance system to control the granular dispersal system based on the defined boundaries of the area and preset material output rate.
  • Page 8 Installing the left/right motors with encoders continues… Figure 1.0.1 (Granular housing hole reference) AG-NAV 1-800-99 AGNAV...
  • Page 9 See diagrams (figure 1.0.3) below. Insure to not force but align the motor shaft into the brass fitting. This step may require the impeller to be rotated until the flat surfaces are aligned. AG-NAV 1-800-99 AGNAV...
  • Page 10: Installing The Control Box - Aap188

    4. Use all 4 mounting holes to fasten the controller to the aircraft. 5. Tie wires to airframe to avoid wires from rubbing on any sharp metal edges. 6. Install wires away from any moving mechanical parts. AG-NAV 1-800-99 AGNAV...
  • Page 11: Fastening The Control Box

    1. Using the control box for a mounting template, mark the 4 mounting holes on the aircraft mounting surface. 2. Using a 3/16” drill bit, drill the 4 mounting holes 3. Fasten the control box with the provided 8-32 fasteners with # 8 Locknuts. AG-NAV 1-800-99 AGNAV...
  • Page 12 Fastening the control box continues… Figure 1.0.4 (Marking and installing the control box) AG-NAV 1-800-99 AGNAV...
  • Page 13: Installing The 2-Way Automatic/Manual Switch And Potentiometer

    5. Locate suitable area to mount the potentiometer. 6. Drill hole according to specification in figure 1.0.6 7. Install potentiometer 8. Label the Panel with as follows: Granular speed control (Manual mode Only) Figure 1.0.5 (Auto / manual switch panel - inches) AG-NAV 1-800-99 AGNAV...
  • Page 14: Installing The Wiring Harness

    8. Route the wire labeled “To Guia/Platinum com 4” from the Granular controller to the Guia console harness labeled Com 3 & 4 port or the Guia Platinum harness labeled com 4. See Figure 1.0.7 for more information on cabling. AG-NAV 1-800-99 AGNAV...
  • Page 15 Installing the wiring harness continues… Figure 1.0.7 (Granular controller harness wiring diagram) AG-NAV 1-800-99 AGNAV...
  • Page 16: Wiring The Spray Switch On The Guia/Platinum System

    Wiring the spray switch on the Guia/Platinum system Since the Granular flow controller requires a signal from the Guia / Platinum system to activate the granular system, the following needs to be wired correctly for the system to operate as intended.
  • Page 17 Wiring the spray switch on the Guia/Platinum system continues… 2. Connect the booms switch to the Relay Spray On/Off wire of the Guia / Platinum system in parallel. See Below. Figure 1.0.9 (Boom 1/ GND to relay spray on/off connection) AG-NAV 1-800-99 AGNAV...
  • Page 18 When this switch is activated the motors will be activated and start controlling based on the selected target rate. See below. Figure 1.1.0 (Optional toggle switch connection) AG-NAV 1-800-99 AGNAV...
  • Page 19: Testing Procedure

    Aircraft Battery. If you have any questions or concerns regarding on the installation or operation of the Granular dispersal system, please contact Ag-Nav support as shown on page 3 of this manual. Testing the granular system 1. Power up the Guia/Platinum system and Granular system.
  • Page 20 19. Select Stop Motor 20. Select Exit The Hardware installation test is now complete. Please see the Guia or Platinum Software Operations Manual for more information on software features of the Granular system including system calibration. AG-NAV 1-800-99 AGNAV...

Table of Contents