17.1 Emergency release
Releasing the door
Requirement: The drain pump is
empty. → Page 31
ATTENTION! Escaping water may
1.
cause material damage.
Do not open the door if you can
see water through the glass.
Pull the emergency release down-
wards with a tool and release.
a The door lock is released.
Insert the maintenance flap and
2.
lock it into place.
Close the maintenance flap.
3.

Transportation, storage and disposal

18 Transportation, stor-
age and disposal
Transportation, storage and disposal
18.1 Removing the appliance
Turn off the tap.
1.
Empty the water inlet hose.
2.
Unplug the appliance's mains plug.
3.
Drain the water.
4.
→ "Cleaning the drain pump",
Page 31
Detach the hoses.
5.
Transportation, storage and disposal en
18.2 Inserting the transit
bolts
Secure the appliance before trans-
portation using transit bolts in order
to prevent transport damage.
Use a screwdriver to remove the 4
1.
cover caps.
Keep the cover caps.
Insert the 4 transit bolts.
2.
→ "Removing the transit bolts",
Page 13
18.3 Using the appliance
again
For further information, see
→ "Installation and connection",
Page 12 and
→ "Starting an empty washing
cycle", Page 16.