Gainsborough GDRP Installation Manual

Round and square dual outlet showers

Advertisement

Quick Links

TM
GDRP
GDSP
GDRE
GDSE
INSTALLATION GUIDE
ROUND AND SQUARE
DUAL OUTLET SHOWERS

Advertisement

Table of Contents
loading

Summary of Contents for Gainsborough GDRP

  • Page 1 GDRP GDSP GDRE GDSE INSTALLATION GUIDE ROUND AND SQUARE DUAL OUTLET SHOWERS...
  • Page 2: Table Of Contents

    (Fittings) Regulations. If in doubt please contact your local water authority. Dual outlet - GDRE and GDSE Components Tools Required (Tools not supplied) Dual Outlet Cool Touch - GDRP and GDSP Components Water Supply Requirements Installation Preparation Fitting the Bar Valve...
  • Page 3 Components Components DUAL OUTLET DUAL OUTLET COOL TOUCH DESCRIPTION DESCRIPTION GDRE AND GDSE GDRP AND GDSP Bar Valve Bar Valve - Round Sealing Washer - Pre- Bar Valve - Square fitted to valve inlets Sealing Washer - Cover Plate Pre-fitted to valve inlets...
  • Page 4: Water Supply Requirements

    Height adjustment *900 – 1240mm combination boiler systems. For gravity pumped systems use 22mm supply pipes and reduce to Models GDRP and GDSP Height adjustment *850 – 1200mm terminate in a ½" BSP female fitting. Note: *measured from the inlet pipe centres to the top of the arm (curved rail).
  • Page 5: Fitting The Bar Valve

    Fitting the Bar Valve Ensuring adequate provision to allow the water to discharge Measure and mark the middle safely to waste, turn on the supplies to flush the system between the proposed pipe centres i.e. through. Attach pressure test equipment and pressure test pipe centres are at 150mm.
  • Page 6: Fitting The Shower Rail Assembly

    2. Where supplied (with GDRE and GDSE Fitting the Shower Rail Assembly models), attach the in-line diverter to Ensuring the rubber sealing washer the rail assembly, making sure that the is in place, reposition the shower rail rubber seal is in place. assembly onto the bar valve outlet, hand tighten the nut to allow some 3.
  • Page 7: Fitting The Drencher Head

    Cartridge Temperature Fitting drencher head Adjustment Ensure the washer is in place, screw the drencher head onto the arm, taking care not to damage the plated This product has been factory set under balanced pressures, and a hot surface. Tighten carefully using water supply of 65°C.
  • Page 8: General Maintenance

    Cleaning the on/off divert headworks General Maintenance Before carrying out any maintenance, ensure the mains water supply is isolated. Once isolated, turn the shower on to release internal pressure. If unsure contact a qualified tradesman. Cleaning the thermostatic cartridge 2. Carefully remove the cap, loosen the screw, then remove the Before carrying out any maintenance, ensure the water supplies control knob and trim (where fitted).
  • Page 9: General Cleaning

    Temperature - Right GDRP & GDSP - To turn on the drencher head rotate the left hand control knob towards the wall. To turn on the handset rotate the left hand control knob away from the wall.
  • Page 10: Troubleshooting

    Troubleshooting Symptom Possible Cause Remedy No flow or low Check shower head, hose and Clean as necessary. Refer to flow rate and/ filters for any blockage. General Maintenance section or varying (page 14-15). Symptom Possible Cause Remedy temperatures. Partially closed stop or service Open stop or service valve.
  • Page 11 Gainsborough Showers Customer Service Department The Flyers Way Westerham Kent TN16 1DE Aqualisa International Jan Palfijnstraat 26/002 Kortrijk Belgium 8500 Customer Helpline: 01959 560760 Fax: 01959 560030 Website: www.gainsboroughshowers.co.uk Email: enquiries@gainsboroughshowers.co.uk Warranty: www.gainsboroughshowers.co.uk/warranty Part No: 706106 Issue 01 Oct 21...

This manual is also suitable for:

GdspGdreGdse

Table of Contents