Quanta Computer D52B-1U User Manual

Full-featured energy efficient 2-way server

Advertisement

Quick Links

QuantaGrid Series
D52B-1U
Full-Featured Energy Efficient 2-Way Server
User's Guide
Version : 1.0

Advertisement

Table of Contents
loading

Summary of Contents for Quanta Computer D52B-1U

  • Page 1 QuantaGrid Series D52B-1U Full-Featured Energy Efficient 2-Way Server User’s Guide Version : 1.0...
  • Page 2 OPYRIGHT Copyright Copyright © 2017 Quanta Computer Inc. This publication, including all photographs, illus- trations and software, is protected under international copyright laws, with all rights reserved. Neither this guide, nor any of the material contained herein, may be reproduced without the express written consent of the manufacturer.
  • Page 3: Table Of Contents

    ABLE OF ONTENT ABLE OF ONTENT About the System Introduction ............1-1 System Features.
  • Page 4 ONVENTIONS Conventions Several different typographic conventions are used throughout this manual. Refer to the following examples for common usage. Bold type face denotes menu items, buttons and application names. Italic type face denotes references to other sections, and the names of the folders, menus, programs, and files.
  • Page 5 RECAUTIONARY EASURES Precautionary Measures Read all caution and safety statements in this document before performing any of the instructions. To reduce the risk of bodily injury, electrical shock, fire, and equipment dam- age, read and observe all warnings and precautions in this chapter before installing or maintaining your system.
  • Page 6 RECAUTIONARY EASURES Table 1: Warning and Cautions (Continued) The enclosure is designed to carry only the weight of the system sled. Do not use this equipment as a workspace. Do not place additional load onto any equipment in this system. Indicates two people are required to safely handle the system.
  • Page 7 RECAUTIONARY EASURES To reduce the weight for easier handling, remove any easily detachable compo-  nents. Never lift or move your system soley by the handle on the component.  Power and Electrical Warnings CAUTION! AKE SURE THE SYSTEM IS REMOVED FROM THE RACK BEFORE SERVICING ANY NON HOT PLUG COMPONENTS HE BUS BAR CLIPS MUST BE DISCONNECTED FROM THE POWER SYSTEM INORDER TO FULLY SEPARATE THE SYS TEM FROM THE POWER SOURCE...
  • Page 8 RECAUTIONARY EASURES Install equipment in the rack from the bottom up, with the heaviest equipment at the bot- tom of the rack. Extend only one piece of equipment from the rack at a time. You are responsible for installing a main power disconnect for the entire rack unit. This main disconnect must be readily accessible, and it must be labeled as controlling power to the entire unit, not just to the system(s).
  • Page 9 RECAUTIONARY EASURES Cooling and Airflow CAUTION! AREFULLY ROUTE CABLES AS DIRECTED TO MINIMIZE AIRFLOW BLOCKAGE AND COOLING PROBLEMS PROPER COOLING AND AIRFLOW OPERATE THE SYSTEM ONLY WITH THE CHASSIS COVERS AIR DUCT INSTALLED PERATING THE SYSTEM WITHOUT THE COVERS AIR DUCT IN PLACE CAN DAMAGE SYSTEM PARTS O INSTALL THE COVERS AIR DUCT...
  • Page 10 RECAUTIONARY EASURES workstation. If one is not available, provide some ESD protection by wearing an antistatic wrist strap attached to chassis ground any unpainted metal surface on the server when handling parts. ESD and handling boards: Always handle boards carefully. They can be extremely sensi- tive to electrostatic discharge (ESD).
  • Page 11 RECAUTIONARY EASURES Heavy object. Indicates two people are required to safely handle the system.
  • Page 12 RECAUTIONARY EASURES Structure of this guide Chapter 1: About the System  “This section introduces the system, its different configuration(s) and the main features.” Chapter 2: Regulatory and Compliance Information  “This section provides regulatory and compliance information applicable to this system.”...
  • Page 13: About The System

    About the System Chapter 1 This section introduces the system, its different configuration(s) and the main features.
  • Page 14: Introduction

    BOUT THE YSTEM NTRODUCTION 1.1 Introduction This document provides an overview of the hardware features of the chassis, troubleshooting information, and instructions on how to add and replace components of the server. For the latest version of this manual, see www.QCT.io. System Features The system comprises a 1U/30.7”...
  • Page 15 BOUT THE YSTEM YSTEM EATURES Table 1.1: System Specifications (Continued) PECIFICATIONS ESCRIPTION ® Chipset Intel C621 / C624 Total slots: 24 Memory type: DDR4 2666 MT/s RDIMM Memory Memory size: 8GB, 16GB, 32 GB* *More options refer to the AVL Onboard (Intel®...
  • Page 16 BOUT THE YSTEM YSTEM EATURES Table 1.1: System Specifications (Continued) PECIFICATIONS ESCRIPTION  (2) USB 3.0 ports  (1) VGA port  (1) RS232 serial port Rear I/O  (1) GbE RJ45 management port  (1) ID LED  (1) MicroSD slot Yes (optional, SPI mode) ACPI ACPI compliance, S0, S5 support...
  • Page 17: Sku Information

    BOUT THE YSTEM YSTEM EATURES SKU information 2.5” All Flash SKU 6x SSD from CPU1 6x SSD from CPU0 SATA/NVMe SATA/NVMe SATA/NVMe SATA/NVMe SATA/NVMe SATA/NVMe SATA/NVMe SATA/NVMe SATA/NVMe SATA/NVMe SATA/NVMe SATA/NVMe 6x SSD from CPU0 12 NVMe 6x SSD from CPU1 CPU0 CPU1 LP-MD2...
  • Page 18 BOUT THE YSTEM YSTEM EATURES 2.5” Tiered SKU Legend: U.2 = SAS/SATA/NVMe SAS/ SATA SAS/ SATA SAS/ SATA SAS/ SATA SAS/ SATA SAS/ SATA SAS/ SATA SAS/ SATA 2 x8 + 1 x16 LP-MD2 PCIe Card P-MD2 PCIe Card + 4 NVMe SSD + 4 NV 1 x16 LP-MD2 + 1 x8 FHHL PCIe Card + 4 NVMe SSD...
  • Page 19 BOUT THE YSTEM YSTEM EATURES Table 2: Intel C621 EEPROM default values*: TEMS ESCRIPTION SSID 89EF VID/DID 152D (SubVendor) 8086 (Vendor)/1528 SR-IOV Management Support for BMC (NCSI/SMBUS/MCTP) NCSI iSCSI boot uEFI/Legacy uEFI/Legacy WOL support ROL support Speed Auto ASPM L0S/L1 Table 3: Intel C624 EEPROM default values*: TEMS ESCRIPTION...
  • Page 20: Package Contents

    BOUT YOUR YSTEM ACKAGE ONTENTS 1.2 Package Contents (1) D52B-1U system  (2) processor heat sinks  (1) power supply unit  (1) power cord (optional)  Note: Note: For exact shipping contents, contact your QCT sales representative.
  • Page 21: A Tour Of The System

    BOUT THE YSTEM OUR OF THE YSTEM 1.3 A Tour of the System System Overview The server is available as a 2.5” and hybrid 3.5” + 2.5” storage drive configuration. The 2.5” storage drive system overview is displayed in the following image: Figure 1-1.
  • Page 22 BOUT THE YSTEM YSTEM VERVIEW Table 4: Component Overview (Continued) ESCRIPTION Riser assembly (CPU0) Support PCIe add-on card installation with riser feature. PSU assembly Redundant power supply unit assembly SuperCAP carrier Housing SuperCAP using in SAS mezzanine card or SAS add-on card DIMM slots (12) DDR4 DIMM slots per CPU Fan module...
  • Page 23: System Front View

    BOUT THE YSTEM YSTEM RONT Table 5: Component Overview (Continued) ESCRIPTION Mainboard System mainboard PSU assembly Redundant power supply unit assembly Riser assembly (CPU1) Support PCIe add-on card installation with riser feature. OCP slot (CPU0) Support OCP 2.0 mezzanine card installation. Riser assembly (CPU0) Support PCIe add-on card installation with riser feature.
  • Page 24: Front Control Panel (Fcp)

    BOUT THE YSTEM YSTEM RONT Figure 1-4. Hybrid 3.5” + 2.5” Storage Drive System Front View Table 7: Front Panel View ESCRIPTION Thumb screw Secure the system to rack frame 3.5” HDD tray 4 x 3.5” SATA/SAS drive USB port Connect to USB device ...
  • Page 25: System Rear View

    BOUT THE YSTEM YSTEM System Rear View Figure 1-6. System Rear View Table 9: System Rear View EATURE ESCRIPTION Power sub-system Main power supply unit (PSU0). See Power Sub-System on page 1-13. System I/O ports See System Rear I/O on page 1-12 Expansion slot Support OCP 2.0 mezzanine card installation (CPU0) Power sub-system...
  • Page 26: Power Sub-System

    BOUT THE YSTEM YSTEM Table 10: System Rear I/O Defintition ESCRIPTION Dedicated NIC Dedicated RJ45 connector Maximum display resolution: 1920x1200 32bpp@60Hz VGA connector (reduced blanking) COM A port DB9 port (Serial_A) for debug or terminal concentrator USB 1 port; connect to USB device USB 3.0 port USB 0 port;...
  • Page 27: Hdd / M.2 Adapter Configuration

    HDD / M.2 A BOUT THE YSTEM DAPTER ONFIGURATION Table 13: Power Supply Unit LED PSU LED C OLOR ESCRIPTION Amber On PSU failure Green On PSU good Green Blinking at 0.5Hz PSU standby Green Blinking at 2Hz PSU cold redundancy standby HDD / M.2 Adapter Configuration The systems are available as a full 2.5”...
  • Page 28: Hybrid 3.5"+2.5" Hdd Configuration

    HDD / M.2 A BOUT THE YSTEM DAPTER ONFIGURATION Hybrid 3.5”+2.5” HDD Configuration HDD4 HDD5 HDD6 HDD7 HDD0 HDD1 HDD2 HDD3 SATA/SAS SKU 3.5” SATA/SAS + 2.5” SATA/SAS/NVM HDD0~HDD7 support SATA/SAS HDD/SSD HDD0~HDD3 support SATA/SAS HDD/SSD HDD4~HDD7 support SATA/SAS HDD/SSD or NVMe Figure 1-10.
  • Page 29: Enabling The Intel® Vmd Technology

    HDD / M.2 A BOUT THE YSTEM DAPTER ONFIGURATION Enabling the Intel® VMD technology Note: You can use Intel® VROC HII to create the RAID volume. These volume can be created at any point before or after your system is successfully running your Windows installation, but may not be used as the boot vol- ume.
  • Page 30 HDD / M.2 A BOUT THE YSTEM DAPTER ONFIGURATION Enable your VMD PCIe Root Port based on the following configuration table: LASH 0-0-0-1A 0-0-0-1A 2-0-2-3A 2-0-2-3A 4-0-2-3C 4-0-2-3C 6-1-0-1A 6-1-0-1A 8-1-0-1C 8-1-0-1C 10-1-2-3A 10-1-2-3A 1-0-0-1B 1-0-0-1B 3-0-2-3B 3-0-2-3B 5-0-2-3D 5-0-2-3D 7-1-0-1B 7-1-0-1B 9-1-0-1D...
  • Page 31: Spanning Raid Data Volumes Across Vmd Domains

    RAID BOUT THE YSTEM PANNING DATA VOLUMES ACROSS DOMAINS Table 17: Intel® VMD on Socket X Screen Description ETUP PTIONS OMMENTS VMD Config for PStack0 Information only. Intel® VMD for Volume [Disable] Enable/Disable Intel® Volume Manage- Management Device for ment Device Technology in this Stack. [Enable] PStack0 VMD Config for PStack1...
  • Page 32 RAID BOUT THE YSTEM PANNING DATA VOLUMES ACROSS DOMAINS 3. Navigate to and select “All Intel VMD Controllers” 4. Navigate to and select “Create RAID Volume” 5. To enable the RAID to be spanned over multiple controllers, highlight the [ ], and press <Enter>.
  • Page 33 RAID BOUT THE YSTEM PANNING DATA VOLUMES ACROSS DOMAINS indicates a setting that is disabled. To enable RAID spanned over VMD Controllers, highlight X and press the <Enter> key. 6. Navigate to and select Create Volume, then press <Enter>. 7. The following message will be displayed: “You have selected NVMe drives that are connected to multiple VMD controllers.
  • Page 34: Led Status Definitions

    LED S BOUT THE YSTEM TATUS EFINITIONS a RAID volume with drives from multiple VMD controllers that RAID volume will not be bootable in a Windows* OS environment. Press ‘y’ to create, ‘n’ to discard”. Note: The message is a warning regarding Windows. This is a BIOS configuration platform and can be compatible with either Windows* Server or Linux distributions.
  • Page 35: Bmc Management Port Leds

    LED S BOUT THE YSTEM TATUS EFINITIONS Table 18: Front Control Panel LEDs Behavior (Continued) OLOR ONDITION ESCRIPTION Critical Failure: critical fan, voltage, temperature state. Blinking Non-Critical Failure: non-critical fan, voltage, temperature state, CPU thermal trip, DC off. Status LED Amber SEL cleared Last pending warning or error has been de-asserted.
  • Page 36 LED S BOUT THE YSTEM TATUS EFINITIONS Table 20: 2.5” Storage Drive LED Status Behavior OLOR ONDITION ESCRIPTION Drive is online Blue Twice per second: Identification Blinking Once per second: Rebuilding Drive Status / Fault Amber HDD failure Slot is empty Drive Active Blue Blinking...
  • Page 37: Enabling Platform Trusted Technology (Ptt)

    (PTT) BOUT THE YSTEM NABLING LATFORM RUSTED ECHNOLOGY Table 22: Storage Drive LED Status Behavior OLOR ONDITION ESCRIPTION Twice per second: Identification Blinking Once per second: Rebuilding Blue Drive is online Drive Status / Fault Amber HDD failure Slot is empty Enabling Platform Trusted Technology (PTT) To enable platform trusted technology feature, you might need to select “Server ME Con- figuration”...
  • Page 38 BOUT THE YSTEM CONFIGURATION SETTINGS Now you can setup the TPM configuration. Table 23: Configuration on Trusted Computing Screen Description ETUP PTIONS OMMENTS TPM 2.0 Device Information only. Displays cur- Found rent TPM Status. Information only. Displays cur- Active PCR banks rent active PCR banks.
  • Page 39: Regulatory And Compliance Information

    Regulatory and Compliance Information Chapter 2 This section provides regulatory and compliance information applicable to this system.
  • Page 40 Server Safety Information To reduce the risk of bodily injury, electrical shock, fire, and equipment damage, read this document and observe all warnings and precautions in this guide before installing or maintaining your server product. In the event of a conflict between the information in this document and information provided with the product or on the website for a particular product, the product documentation takes precedence.
  • Page 41 Intended Application Uses This product was evaluated as Information Technology Equipment (ITE), which may be installed in offices, schools, computer rooms, and similar commercial type locations. The suitability of this product for other product categories and environments (such as medical, industrial, residential, alarm systems, and test equipment), other than an ITE application, may require further evaluation.
  • Page 42 When replacing a hot-plug power supply, unplug the power cord to the power supply being replaced before removing it from the server. To avoid risk of electric shock, turn off the server and disconnect the power cord, telecommunications systems, networks, and modems attached to the server before opening it. Power Cord Warnings If an AC power cord was not provided with your product, purchase one that is approved for use in your country.
  • Page 43 Rack Mount Warnings Note: The following installation guidelines are required by UL for maintaining safety compliance when installing your system into a rack. The equipment rack must be anchored to an unmovable support to prevent it from tipping when a server or piece of equipment is extended from it. The equipment rack must be installed according to the rack manufacturer's instructions.
  • Page 44 Do not attempt to recharge a battery. Do not attempt to disassemble, puncture, or otherwise damage a battery. Cooling and Airflow Caution: Carefully route cables as directed to minimize airflow blockage and cooling problems. For proper cooling and airflow, operate the system only with the chassis covers installed. Operating the system without the covers in place can damage system parts.
  • Page 45 After you have completed the six SAFETY steps above, you can remove the system covers. To do this: 1. Unlock and remove the padlock from the back of the system if a padlock has been installed. 2. Remove and save all screws from the covers. 3.
  • Page 46 The rail racks are designed to carry only the weight of the server system. Do not use rail-mounted equipment as a workspace. Do not place additional load onto any rail-mounted equipment. Heavy object. Indicates four or more people are required to safely handle the system.
  • Page 47 Electromagnetic Compatibility Notices FCC Verification Statement (USA) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
  • Page 48 As this equipment has undergone EMC registration for business purpose, the seller and/or the buyer is asked to beware of this point and in case a wrongful sale or purchase has been made, it is asked that a change to household use be made. Regulated Specified Components To maintain the UL listing and compliance to other regulatory certifications and/or declarations, the following regulated components must be used and conditions adhered to.
  • Page 49 設備名稱: 伺服器 ,型號(型式):D52B-1U 限用物質及其化學符號 六價鉻 多溴聯苯 多溴二苯醚 單元 鉛 汞 鎘 Unit Lead Mercury Cadmium Hexavalent Polybrominated Polybrominated (Pb) (Hg) (Cd) chromium biphenyls diphenyl ethers (PBB) (PBDE) 金屬機殼 ○ ○ ○ ○ ○ ○ 電路板 ○ ○ ○ ○ ○...

This manual is also suitable for:

Quantagrid series

Table of Contents