Alen BreatheSmart 75i - HEPA Air Purifier Manual

Alen BreatheSmart 75i - HEPA Air Purifier Manual

Also See for BreatheSmart 75i:

Advertisement

Alen BreatheSmart 75i - HEPA Air Purifier Manual

USING YOUR PRODUCT

PLEASE NOTE:
The BreatheSmart 75i has a capacitive touch panel. The buttons only operate with a quick, light touch. Holding the buttons down will not activate the controls properly. A chime will indicate that the control has registered your touch.

Identification of Parts

Identification of Parts
BreatheSmart 75i Control Panel

Operating Your Unit

  1. Plug your air purifier into a grounded outlet.
  2. Touch Power Button in the center to start the air purifier. When your unit is on, the lights will light up. To turn off the lights on your unit, touch the Power Button. To turn off the air purifier, touch the Power Button again after the lights have turned off.
  3. The Color Ring around the Power Button indicates the air quality being measured by the particle sensor.
COLOR MEANING
Blue Very low level of airborne particles detected
Green Low level of airborne particles detected
Orange Medium level of airborne particles detected
Red Significat level of airborne particles detected
Purple Very significant level of airborne particles detected
  1. Press IONIZER to activate the ozone-safe ionizer. Activation of the ionizer enhances your unit's ability to remove airborne particles (similar to the way dust is attracted to a TV screen). Press the ionizer button again to turn off.
  2. FILTER life Indicator — There are three lights above the FILTER button: Green, Yellow, and Red. The Green light will be illuminated for most of the life of the filter. The Yellow light will come on shortly before your filter should be replaced. This is the ideal time to order a new filter. The Red light will be illuminated when it is time to replace the filter.
  3. After changing the filter, hold the FILTER button down for five seconds. The Red light will be reset to Green.
  4. Press TIMER to have the air purifier run for a set amount of hours (either two, four, or twelve) before turning off.

KNOW YOUR PRODUCT

When using the air purifier for the first time in a room, we recommend that you use a higher fan speed like speed four (4) or Turbo (T), for at least two hours in order to clean the room's air initially. Then, we recommend that the air purifier run continuously on speed two (2) or three (3) or be set on Auto mode.

Features

  • True HEPA filtration captures dust, allergens, and airborne pollutants
  • 5 fan speeds with a two, four, and 12+ hour timer to control air circulation
  • Filter change indicator light keeps replacements on schedule
  • Simple and intuitive touch button controls
  • Auto-off safety feature when front cover is removed

CARE & MAINTENANCE

Turn The Lights Off/On

To turn the lights off on your unit, touch the Power Button. The lights will go out but the unit will not turn off. Touch any button to turn the lights back on, or touch the Power Button a second time to turn the unit off completely.

Replacing The Filter

The Filter Life Indicator has 3 lights: Green, Yellow, and Red. The Green light will be illuminated for most of the life of the filter. Yellow light will come on shortly before your filter should be replaced. This is the ideal time to order a new filter. You may order a new filter at www.alen.com/filters or by calling 1-800-630-2396. The Red light will be illuminated when it is time to replace the filter.

The filters used in Alen Air Purifiers are not designed to be washed, cleaned or otherwise reused. Over time, the filters become overloaded with particles, decreasing their filtration performance. We recommend regular filter replacements to extend the life of your air purifier and maximize performance.

The screen layer of the filter, known as the Pre-Filter, captures large dust and hair. This layer can be vacuumed periodically to maintain efficient operation of the unit.

Reset the Filter Indicator

After replacing the filter, hold the FILTER button down for 5 seconds. The Red light will be reset to Green.

Cleaning the Control Panel

To avoid scratching the control panel, do not use abrasive/caustic cleaning solutions or scrubbing pads. With the unit unplugged, dampen a clean towel with soap and water to clean the control panel, then dry gently with a soft cloth or paper towel. Glass cleaner (e.g. Windex) is also OK. To avoid damaging electronic components** DO NOT allow liquid to seep into the unit.

Why You Should Replace Your Filter

  • You purchased an Alen Air Purifier to improve the quality of your indoor air.
  • Changing your filters on time is the only way to maintain an optimal level of air quality.
  • Excessively dirty filters can compromise the level of clean air your air purifier can provide.

Alen's Filter Subscription Plan

Regular replacement of your filter will extend the life of your air purifier and keep your air clean. Alen filters provide efficient filtration for 9 to 12 months depending on usage and conditions. With Alen's convenient Filter Subscription Plan, your filters will be shipped right to your door, exactly when needed.
Savings — Save 10% over retail and get FREE SHIPPING on every filter.
Convenience — Choose your desired shipping frequency and never run out of filters.
Superior Coverage — Alen's exclusive Forever Guarantee begins when you complete Product Registration and activate your Filter Subscription (See WARRANTY AND EXTENDED COVERAGE).

To get started, simply visit www.alen.com/activate or call 1-800-630-2396.

How To Replace The Filter

  1. Always unplug the unit when installing a filter.
  2. Distinguish the front side from the back side of the filter. The front side has a screen pre-filter and pull loop at the top.
  3. Place the used filter in a plastic bag to prevent dust from re-entering the air.
  1. With the unit standing upright, pull firmly on the cover near the intake vents with one or both hands to release the magnets.
    How To Replace The Filter - Step 1
  2. After pulling the cover out, lift it away from the unit.
  3. Remove used filter by pulling out and down on the pull loop. Place the used filter in a plastic bag to prevent dust from re-entering the air.
    How To Replace The Filter - Step 2
  4. Take new filter out of the plastic bag, insert the bottom. Firmly push top of filter frame in until it clicks into place.
  5. Insert the bottom hooks on the front cover first and then the upper part of the cover will snap into place.
    How To Replace The Filter - Step 3


RISK OF ELECTRIC SHOCK - To reduce risk of electric shock, do not perform any servicing other than that contained in the operating instructions.

TROUBLESHOOTING TIPS

Unit will not power on

Check that the power cord is properly seated into the back of the purifier. Firmly push top of filter frame up and in until it clicks. Last, check that front panel is on properly (fit snugly to the purifier).

How do I reset the filter indicator lights? I put in a new filter but the red or yellow lights are still illuminated.
After changing the filter, RESET the filter indicator by holding down the FILTER LIFE button for 5 seconds while the unit is ON. The light above the FILTER LIFE button should reset to green.

How do I find out what electrical specifications my unit needs?
Please refer to the rating label on the back of the unit. Here you will find your unit's voltage, hertz, amps and outlet requirements.

Can I clean the filter?

The screen layer of the filter, known as the Pre-Filter, captures large dust and hair. This layer can be vacuumed to maintain efficient operation of the unit. No other layers or parts of the filter can be washed, cleaned, or otherwise reused. Please replace the filter regularly to maintain optimal performance.

I have an issue not listed in this manual

Please visit www.alen.com and send us a message or call 1-800-630-2396 during business hours. A customer service representative will respond to your inquiry in a timely manner.

What information do I need when I contact customer service for warranty?
Please refer to the rating label on the back of the unit. This rating label has your unit's serial number and other important information we need to assist you.

PRODUCT SAFETY

This manual provides important safety messages regarding your electrical home appliance. Always read, follow, and, save all safety directions.

Location Requirements

  • Use a level surface at least 6" (15.2cm) from heat sources such as ranges, dryers, or heaters.
  • Do not block air vent openings.
  • Never insert fingers or foreign objects into air vents.
  • Do not place air purifier on a soft or unstable surface such as a bed or sofa.
  • Do not use in a window.
  • Do not use next to a source of heat such as a range, heater, or dryer.
  • Do not use near any source of water such as a sink, bath, shower, or swimming pool.
  • Operate indoors only.

burn hazardshock hazard
Electrical and Safety Requirements - Reduce the risk of fire or electric shock.
Failure to follow these instructions can result in property damage, injury, or death.

  • Do not connect unit to any electrical socket that is damaged.
  • Do not plug the air purifier into an outlet controlled by a dimmer switch.
  • shock hazard Do not insert or pull out plug with wet hands, it may cause electric shock.
  • Do not use an adapter. Do not use an extension cord.
  • Use only in the proper electrical socket type. Socket type (voltage & hertz) can be found on the unit's back panel label. Incorrect socket use can damage/destroy the unit.
  • shock hazardburn hazard
    Do not exceed the rating of the power outlet or connection device. May cause electric shock or fire due to excess heat generation.
  • Never try to take apart or repair the unit by yourself.
  • Disconnect power immediately if you notice strange sounds, smells, or smoke.
  • Change your filter at the recommended interval to avoid particle and dust buildup.
  • Ensure filter is correctly installed before turning on unit. Do not run unit without a filter.
  • Do not cover the unit or impede airflow.
  • Do not drop the unit, as this can result in damage.
  • burn hazardshock hazard
    Do not place heavy objects on the power cord and be sure the cord is not compressed as there is danger of fire or electric shock.
  • burn hazard Do spray insecticides or any other flammable sprays near the ujnit. It may cause explosion or fire.

  • To reduce the risk of electric shock, this equipment has a polarized plug (one blade is wider than the other). This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact qualified personnel to install the proper outlet. Do not alter the plug in any way.

WARRANTY AND EXTENDED COVERAGE

Please visit https://alen.com/foreverguarantee for all warranty information. For any questions, please contact customer service by calling 1-800-630-2396 or email service@alen.com
Alen Corporation
9200 Waterford Center Blvd. Suite 600
Austin, TX. 78758
www.alen.com

Documents / Resources

References

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download Alen BreatheSmart 75i - HEPA Air Purifier Manual

Advertisement

Need help?

Need help?

Do you have a question about the BreatheSmart 75i and is the answer not in the manual?

Questions and answers

Table of Contents