Using the I-Control Ampere
Function (Optional)
1
Turn the appliance on.
2
When Operation in Cooling / Heating Mode.
3
Press Ampere Ctrl. button.
• Press Ampere Ctrl. button repeatedly to
select each step.
NOTE
• Each step (L1~L6) : The power input is setting
Ampere (A) matched each step (L1~L6) to
operate the appliance.
• Each Models Each Steps setting Ampere (A)
Product
1
Capacity
ton
Operating
Step
Mode
Level
L1
2
L2
3
L3
4
Cooling
L4
5
L5
6
L6
7
L1
3
L2
4
L3
5
Heating
L4
6
L5
7
L6
8
1.5
2
2.5
ton
ton
ton
Ampere (A)
3
4
5
4
5
6
5
6
7
6
7
8
7
8
9
8
9
10
4
4
5
5
5
6
6
6
7
7
7
8
8
8
9
9
9
10
• When ICA function setting to product, each
Step Level(L1~L6) would be display on the
wireless remote controller display screen,
and Ampere what is matching each steps
would be display on the Indoor unit display
screen.
− Example (4A, 10A)
•
will be blinking on the indoor unit, when
the air conditioner needs more Ampere for
operating than setting ampere's operation
range.
− If you change the step by pressing Ampere
Ctrl. button,
blinking will be disappeared.
• This function is available with Cooling and
Heating Mode.
• Capacity may decrease when I-Control
Ampere mode is selected.
• Desired temperature is displayed about 5
seconds if you press Fan Speed,
button.
• Room temperature is displayed about 5
seconds if you press Room Temp. button.
• This function is designed to maintain the set
ICA Level in case of cut the power supply off
with out canceling the function.
• Current Ampere may be more than use setting
depending on outdoor temperature or under
the specific circumstances for product
protection such as defrost, low voltage.
EN
or
23