LED Steady/Flashing Tower Lights
ST45/ ST56/ ST80
30
60
23
44
Thank you for purchasing Qlight's products. Please read this user manual carefully
prior to installation and operation to ensure safe and correct use.
Precautions for Safety
Failure to follow the instructions below may cause a loss of life or serious physical injury.
1. During wiring or maintenance, please completely turn off the power of the product. (Failure to follow this may lead to an electric shock.)
2. Do not install the product in locations that subjects it to excessive dust or water other than the conditions designated by the IP protection
ratings indicated for each product. (Failure to follow these instructions may cause a fire to the product, electric shock, physical injury,
malfunction or damage to the product.)
3. Do not alter or repair this product. If maintenance or repair service is required, please contact your local Qlight contact point. (Failure to
follow these instructions may lead to fire, electric shock, or product damage.)
4. Please apply the correct voltage to the product. (Failure to follow these instructions may lead to fire, electric shock, or product damage.)
5. When the product is applied to a condition that may impact lives or property, please make sure to have a double safety device. (Failure to
follow this may cause damage to property, fire, electric shock and loss of life.)
Precautions for Correct Use
Failure to follow the proper instructions may cause damage to property, the product, or malfunction of the
product that would void the warranty.
1. Please remove any objects that can interrupt ventilation around the product.
2. Please turn off the power of the product immediately if it fails to operate properly.
3. Carefully wire the product according to each product's specification.
4. Please be careful in preventing chemicals such as thinner, benzene, etc. in contact with the surface of the product.
5. Do not apply excessive force/impact to the product.
6. Failure to follow any of the instructions above may cause malfunction or damage to the product, fire, and electric shock.
Please scan the QR code for more
detailed product information.
www.qlight.com
90dB
85dB
1

Advertisement

loading

Summary of Contents for Qlight ST45 Series

  • Page 1 3. Do not alter or repair this product. If maintenance or repair service is required, please contact your local Qlight contact point. (Failure to follow these instructions may lead to fire, electric shock, or product damage.) 4.
  • Page 2: Ordering Specifications

    Ordering Specifications ST45/ 56ML 110/220 ST45/ 56L 110/220 LW18 [Model number] [Layer count] [Voltage] [Color] [Model number] [Layer count] [Voltage] [Color] [Mounting option] • ST45/ 56ML • 1-1 Layer • 12-DC12V R-Red • ST45/ 56L • 1-1 Layer • 12-DC12V R-Red •...
  • Page 3: Product Specifications

    Product Specifications ST45ML ST45L • • Layer Layer Model number Voltage Certificate Weight Color Model number Voltage Certificate Weight Color count count AC/DC12V AC/DC12V 0.19kg 0.35kg AC/DC24V AC/DC24V 0.19kg 0.35kg R-Red R-Red AC110V AC110V 0.25kg 0.45kg AC220V AC220V 0.25kg 0.45kg AC/DC12V AC/DC12V 0.21kg...
  • Page 4 Product Specifications • ST80MEL • ST80EL Layer Layer Model number Voltage Certificate Weight Color Model number Voltage Certificate Weight Color count count AC/DC12V AC/DC12V 0.36kg 0.58kg AC/DC24V AC/DC24V 0.36kg 0.58kg R-Red R-Red AC110V AC110V 0.59kg 0.81kg AC220V AC220V 0.59kg 0.81kg AC/DC12V AC/DC12V 0.45kg...
  • Page 5 Dimensions (Units : mm) ST45ML/ ST45L • ST45ML : AC/DC ST45ML-BZ : AC ST45MLF-BZ : AC ST45ML-BZ : DC ST45MLF : AC ST45MLF : DC ST45MLF-BZ : DC Ø45 Ø45 Ø45 LAYER LAYER LAYER PCD30 Ø8 CABLE ENTRY 360°/3-M4 BOLT ST45L : AC/DC ST45L-BZ : AC ST45LF-BZ : AC...
  • Page 6 Dimensions (Units : mm) ST56MEL/ ST56EL • ST56MEL : AC/DC ST56MEL-BZ : AC ST56MEL-W : AC ST56MEL-W : DC ST56MEL-BZ : DC ST56MELF-BZ : AC/DC ST56MELF-W : AC ST56MELF-W : DC ST56MELF : DC ST56MELF : AC Ø56 Ø56 Ø56 Ø56 LAYER LAYER...
  • Page 7 Dimensions (Units : mm) ST80MEL/ ST80EL • ST80MEL : AC/DC ST80MEL-BZ : AC/DC ST80MEL-W ST80MELF : AC/DC ST80MELF-BZ : AC/DC ST80MELF-W Ø80 Ø80 LAYER LAYER PCD50 PCD50 Ø8 CABLE ENTRY 360°/3-M4 BOLT Ø8 CABLE ENTRY 360°/3-M4 BOLT ST80EL : AC/DC ST80EL-BZ : AC/DC ST80EL-W ST80ELF : AC/DC...
  • Page 8: Wiring Instructions

    Wiring Instructions ■ Wiring using external contact • In case of wiring with external contacts, refer to the wiring diagrams below according to your product’s type and voltage setting. Wiring diagrams Wiring diagrams DC Steady AC Steady External contact External contact ST45ML ST45ML Red(R)
  • Page 9 ■ Wiring using transistor • When using a transistor, please choose between the NPN or PNP type transistor which best matches the voltage and product type, then connect them correctly according to the wiring diagrams below. Wiring diagrams DC Steady NPN-Transistor External Transistor-NPN PNP-Transistor...
  • Page 10: Parts Definition

    • If the product is installed in locations that subject it to excessive dust or water other than the designated IP protection rating indicated(IP44), it may cause malfunction or damage to the product. • For further information, please visit our website(www.qlight.com).
  • Page 11 • Please refer to the dimensions below for installation of mounting brackets. ■ ST45ML/ ST56MEL/ ST56ML/ ST80MEL/ ST80ML - Direct Mounting Type Model Dimensions PCD30~40 Ø12 360°/3-Ø5 HOLES PCD30~40 ST45 series 360°/6-Ø5 HOLES ST56 series 4-Ø4.5 HOLES Ø12 CABLE ENTRY 4-Ø4.5 HOLES TWS45...
  • Page 12 ■ ST45L/ ST56EL/ ST56L - Pole Mounting Type Model Dimensions ST45 series ST56 series Ø18 Ø18 M18x1.5 THREAD 2-Ø8.5 HOLES 18mm SCREW & NUT LB18 4-Ø5 HOLES Ø18 Ø28 Ø18 4-Ø5 HOLES 1/2" PF 12x22 CABLE ENTRY Ø70 LW18 SZ18 Ø18...
  • Page 13 ■ ST80EL/ ST80L - Pole Mounting Type Model Dimensions ST80 series Ø24 Ø24 M24x1.5 THREAD 2-Ø8.5 HOLES 24mm SCREW & NUT LB24 Ø24 4-Ø5 HOLES Ø24 Ø35 4-Ø5 HOLES 12x22 CABLE ENTRY 1/2" PF Ø90 69.5 LW24 SZ24 Ø24 Ø24 4-Ø5.5 HOLES Ø11 CABLE ENTRY 4-Ø6 HOLES...
  • Page 14 Product installation direction ■ Install the product in accordance with the manual. Otherwise rainwater or moisture may penetrate into the product. ㆍBEACON/SIGNALING LIGHT ※ For products with a protection rating of less than IPX4, please install it vertically. Power cord inlet part shall not be facing the sky. ㆍ...
  • Page 15 MEMO...
  • Page 16 Factory | 185-25, Mukbang-ro, Sangdong-myeon, Gimhae-si, Gyeongsangnamdo, Korea Tel. +82-55-328-1111(Toll free. +82-80-328-1111) Qlight Overseas Sales Dept | 704 Nakdong-daero, Sasang-gu, Busan, Korea(Eomgung-Dong) Tel : +82-51-620-4100 Qlight Public Relations & Marketing Team Offi ce | 704 Nakdong-daero, Sasang-gu, Busan, Korea(Eomgung-Dong) Tel. +82-51-245-0017 SHANGHAI Qlight Electronic Co., Ltd. www.qlight.com www.qlightcn.com | qlightcn@qlight.com China Factory/ Shanghai Sales Offi...