1
1.2 Intended Use ........................................................................................................ 2
1.3 Safety Instructions ................................................................................................ 2
2
2.1 Operating Principle ............................................................................................... 3
2.2.1
Evaluation Unit ..................................................................................................................... 3
2.2.2
Sensor Electrode ................................................................................................................. 3
2.2.3
Concepts .............................................................................................................................. 3
3
System ..................................................................................................... 4
3.1 Evaluation Unit ..................................................................................................... 4
3.2 Sensor Electrodes ................................................................................................ 5
3.3.1
3.3.2
3.3.3
Indication Elements .............................................................................................................. 7
3.4 Installation ............................................................................................................ 7
3.4.1
3.5 Technical Data ...................................................................................................... 9
3.6 Disturbances ......................................................................................................... 9
4
Montage & Cabling ............................................................................... 10
4.1 System Arrangement .......................................................................................... 10
S-SW-8 video:
http://www.ucma.de/schaltschwelle-s-sw-8/
Warning! Advisement about the difference between S-SW-8 and S-SW-3:
Differently of the S-SW-3, the first time that S-SW-8 starts operation, an adjustment
must be triggered with empty sensor detection area. To do this, press SW1 at least 5
seconds, until the LED4 lights up red (calibration started). The calibration process is
completed when LED1 flashes green. Only after that, objects can enter the detection
area (relay switches on) or the sensitivity can be changed. We recommend using the
automatic sensitivity adjustment.
UNICONTROL Electronic GmbH
Freinsheimer Straße 3
D-68219 Mannheim
www.unicontrol-gmbh.de
Object Detector
S-SW-8
Tel.: +49 621 87982 0
Fax +49 621 87982 35
Manual
1
/11
4/8/2024