Download Print this page
ebm-papst 8560 VW Operating Manual
ebm-papst 8560 VW Operating Manual

ebm-papst 8560 VW Operating Manual

Advertisement

Quick Links

Operating manual
8560 VW
Product type, manufacturing date (calendar week/year of construction)
and if required, conformity mark can be found on the nameplate on the
product.
Please provide us with the contents of the nameplate when making
enquiries about the product.
ebm-papst St.Georgen GmbH & Co. KG
Hermann-Papst-Straße 1
D - 78112 St.Georgen
Phone: +49 (0) 7724 / 81-0
Fax: +49 (0) 7724 / 81-1309
info2@de.ebmpapst.com
www.ebmpapst.com
As per: 08.10.2019
Version: 1 3
Article number: 9244014626
Original operating manual
INDEX
1 SAFETY REGULATIONS AND INFORMATION
2 INTENDED USE
3 TECHNICAL DATA
4 CONNECTION AND COMMISSIONING
5 FAULTS, POSSIBLE CAUSES AND REMEDIES
6 COMPLIANCE
1
SAFETY REGULATIONS AND INFORMATION
Read the operating manual carefully before commencing work at the
product. Pay attention to the following warnings to avoid risk to
persons or malfunctioning.
This operating manual is an integral part of the product.
In the event of resale or change of ownership the operating manual
must accompany the product. This operating manual may be copied
and provided as information on potential risks and their avoidance.
Hazard classification of warning notices
The following risk ratings are used in this operating manual to denote
potential risk situations and important safety instructions:
Qualification of personnel
Only skilled electricians are permitted to install the product, to carry out
the test run and to work at the electrical unit.
Only instructed and authorized skilled personnel are permitted to
transport, unpack, operate and service the product.
Basic safety regulations
Safety risks related to the product must be reassessed after installing
in the final device.
The operating manual was developed in accordance with European
market requirements and may need adapting to the market
requirements of the country in question.
When working at the product, observe the following:
Do not make any changes to the product.
1
3
3
4
6
6
page 1 of 7
DANGER
This is a potentially dangerous situation
and warns of an impending health risk
or risk of fatal injury if this warning is
not observed. Observe this warning.
WARNING
The dangerous situation can occur and
can result in major or fatal injuries if the
warning is not observed. Work with
extreme care.
CAUTION
The dangerous situation can occur and
can result in minor injuries or damage
to property if the warning is not
observed.
NOTE
A potentially dangerous situation can
occur and results in damage to
property if not avoided.
WARNING
Impermissible high load
Stop the product immediately after
impermissible loading (e.g. impact,
heat, overvoltage).

Advertisement

loading

Summary of Contents for ebm-papst 8560 VW

  • Page 1 Please provide us with the contents of the nameplate when making enquiries about the product. Qualification of personnel ebm-papst St.Georgen GmbH & Co. KG Only skilled electricians are permitted to install the product, to carry out Hermann-Papst-Straße 1 the test run and to work at the electrical unit.
  • Page 2 Electrical voltage and current CAUTION DANGER High temperature at motor housing. Electrical voltage Risk of burns Regularly check the electrical Provide adequate protection against equipment of the product. accidental contact. Eliminate immediately loose connections and defective cables. Transport CAUTION Only transport the product in its original packaging. Secure during In the event of a fault, the product is transport.
  • Page 3: Intended Use

    Do not operate your product in the resonance range. contact, electrical shocks, impact of foreign objects or water and the usage at altitudes higher than 2000 meters. Contact ebm-papst if you have specific queries regarding the product. page 3 of 7...
  • Page 4: Connection And Commissioning

    CONNECTION AND COMMISSIONING DANGER Electrical voltage Connect mechanical parts As additional protection we recommend the installation of a CAUTION RCD (residual current protective Risk of cutting/squashing when device), which is adequate for removing the product from the product, usage and application. packaging and during mounting.
  • Page 5 Requirements: - Before connecting the product, ensure that the supply voltage corresponds with the product voltage. - Check whether the data on the nameplate corresponds with the interface data. Only use cables that are designed for the current on the nameplate and the corresponding ambient conditions.
  • Page 6: Faults, Possible Causes And Remedies

    FAULTS, POSSIBLE CAUSES AND REMEDIES COMPLIANCE Replace your product by a new one, do not repair it. The product bears the CE mark. DANGER The CE mark is affixed to adequately sized nameplates. Electrical voltage at motor Within the meaning of the EMC Guideline 2014/30/EU this document is Wait five minutes after the voltage intended as: (all poles) has been switched off...