Do you have a question about the SOLIHP12INV-DF and is the answer not in the manual?
Questions and answers
Subscribe to Our Youtube Channel
Summary of Contents for Solimpeks SOLIHP12INV-DF
Page 1
INSTALLATION & USER MANUAL SOLIHP12INV-DF...
Page 3
10 years. In accordance with the relevant law, manufacturers and vendors ensure to have the necessary spare parts and service the device within this period in order for the devices to perform their functions. MANUFACTURING COMPANY Fevziçakmak, 10753 sok. 3-3/A, 42050 Karatay/KONYA http: // www.solimpeks.com...
The unit is recommended with an READ THESE INSTRUCTIONS CAREFULLY BEFORE integrated backup heater to provide INSTALLATION. additional heating capacity during very low outdoor temperatures. The backup KEEP THİS GUIDE WITH YOU FOR heater also acts as a backup in case FUTURE REFERENCE.
Page 6
Turn off all the operating power DANGER sources before touching electrical Indıcates very potentially parts. hazardous situation which, if not avoided, could result in death or serious injury. CAUTION WARNING Indicates a potantially hazardous Tear and discard plastic packaging situation which, if not avoided, could bags to prevent children from playing.
Page 7
The electrical threshold may rise Make sure that all the electric wiring are safe, suitable cables are used, and abnormally as a result of a lightning it does not have an influence on the strike. cables or end fitting of external power. ...
Page 8
persons with reduced physical, treatment. Do not dispose of electrical sensory or mental capabilities, as well appliances as unsorted municipal persons lacking sufficient waste, separate collection experience and knowledge, if they facilities. Contact your local authority have been given supervision or information available instruction concerning use of this...
3.3. Device Positioning MUST READ BEFORE POSITIONING THE DEVICE! The device should be installed outside and away from rooms that will be exposed to noise, such as bedrooms, living rooms! The device must be installed on a horizontal, flat, solid and permanent substrate! ...
3.4. The electrical panel is as follows; SOLIHP12INV-DF Electrical Connection Information electrical connection such maintenance must be carried out by qualified and experienced technical installers! Please follow local regulations for electrical wiring and the instructions in this user manual!
Power and resistance cables must be 3.4.1. Electrical Panel Component Descriptions passed through the holes under the Those in the SOLIHP12INV-DF electrical fountain installation of the device and panel and the task description are like connected to the relevant terminals on components;...
Page 14
2.Control Card 1.Control Card EXPLANATION OUT-3 Three-way valve output AC card supply EXPLANATION Neutral output OUT-3 Three-way valve output Transformer AC supply AC card supply Neutral output Transformer 12V AC output Transformer AC supply Display communication Transformer 12V AC output BTW temperature sensor input Display communication DHW temperature sensor input...
Page 15
Relays Klemens Table With 2 relays, fan speed, fast and slow rotation are controlled. The OUT-1 output of the 1st control card is connected to the A1 pin of the 1st relay. Neutral connection is made to A2 leg. Entry number 11 is entered into the supply section in the terminal table.
Page 16
Screen-Card Connection Please make sure the power supply is off during electrical connection or maintenance! Errors caused by the user are not covered by the warranty!
3.5. Assembly Precautions Ensure that the refrigerant system remains sealed against external gases The negativities that may arise and air. If air or other gases enter the from the operations performed refrigerant circuit, high system other than those specified in the pressures can cause burst pipes and guide are not covered by the injury.
3.6. SOLIHP12INV-DF Wiring Diagram You can connect your SOLIHP12INV-DF heat pump to the SOLITANK 300L boiler as follows; Technical specifications about SOLITANK 300L boiler are as follows; General Information Curb Weight Full Weight Dimensions 1726x540 °C Allowed Max. Boiler Water Temperature Pipe Connections ¾”...
Page 19
SOLİKOMBİ 300L You can connect your SOLIHP12INV-DF heat pump to boiler as follows; Technical specifications about SOLIKOMBI 300L boiler are as follows; General Information Curb Weight Full Weight Dimensions 1726x540 °C Allowed Max. Boiler Water Temperature Pipe Connections 1 ¼”...
Adjust the functions of the system with 4.3. Deactivating the Device the wired controller. If the system is SOLIHP12INV-DF put it into standby mode planned for heating only mode, set from the wired controller, if it will be out of DHW to OFF.
5. MAINTENANCE NTC-5K (For all other sensors) Temp. Resistance Temp. Resistance 5.1. Regular Maintenance (°C) (kΩ) (°C) (kΩ) In general, this device requires no special 63,73 2,03 maintenance. It is sufficient to carry out 37,40 1,48 regular checks in line with the following 22,72 1,07 items;...
6.2.2. Function Settings Esc Button Under the function setting menu item, you In the programming menu, press this key to can turn on or off the DHW function, select return to the previous menu or save the the heating and cooling function or turn it off. changed value;...
For other parameters under submenu mode, please refer to the table below and follow the same steps; Factory Main Menu Sub Menu Parameters Case Explanation Settings ON/OFF Cooling Automatic Automatic Heating curve with water temperature control Heating Heating The water temperature is Heating controlled at the set value.
Open or closed ready situation Parameter Settings Function Settings Password Login Unit Status Enter Password System Values Select Parameter Type System Values Select Parameter Turn back Confirm Confirm 6.2.4. Parameter Settings Qualified technicians to heat pumps and menu setting for service level are allowed. consists of two breaks: system and defrost, Set Value this is very important to work with correct...
Page 25
Sub Menu Parameters Explanation Main Menu Shows the value received from the domestic water DHW Temp. temperature sensor. Shows the value received from the buffer tank BTW Temp. temperature sensor. Shows the value received from the buffer tank inlet BTW Inlet Temp. temperature sensor.
Page 26
Default Main Param Sub Menu Rate Setting Explanation Menu eters DHW temperature hysteresis - DHW DHW ΔT heating start at DHW set value - 1 ~ 20 hysteresis BTW temperature hysteresis- Start BTW ΔT heating at hot water setpoint - 1 ~ 20 hysteresis Target superheat of EEV control in...
Page 27
Minimum heating time between two Def. 30 ~ 90 40 min. Cycle min. defrost cycles Defrosting allowed when Def. evaporator temperature. (below this Start -20 ~ 5 Temp. value) Defrost When the evaporator temperature is Def. Parameter reached, the defrosting process is Stop 1 ~ 30 Temp...
6.2.5. Failure Record Under the menu item name of failure Set Date records, you can view the last 8 fault records and the time of occurrence of each fault. Failure Record Select Clock Set Clock 6.2.6. Time Settings Follow the same STAGES to set the ON / With the menu item time setting, you can set OFF timer if needed.
Page 29
Error Explanation Solution Codes Check the communication link between the controller and the Communication error unit PCB. Check the communication link between the unit control PCB and the system control PCB Inlet temperature sensor error Check the inlet water temperature sensor Outlet temperature sensor error Check the leaving water temperature sensor Very low or no water flow rate, check the particulate filter...
7. SOLIHP12INV-DF TECHNICAL SPECIFICATIONS MODEL SOLIHP12INV-DF ELECTRICAL FEATURES Power source 230 V/50 Hz Maximum Power Input Maximum Current 24,1 IP Evaluation IP X4 HEATING MODE A7/W35 12,2 A7/W45 11,5 Heating Capacity A2/W35 11,3 A-7/35 A7/W35 2,85 A7/W45 Power Consumption A2/W35...
Page 31
TECHNICAL SERVICE FORM FORM NO: SOLİMPEKS ENERJİ SAN. Ve TİC. A.Ş. Adress: Fevziçakmak, 10753. Sk. 3-3/A, 42050 Karatay/Konya Tel: 444 0 602 Web: https://www.solimpeks.com Service Service Application Date Application Date Work Start Date Work Start Date Work Completion Work Completion Date...
Page 32
WARRANTY CERTIFICATE Manufacturer or Importer Company Seller Company Title: Title: Adress: Adress: Telephone: Telephone: Fax: Fax: E-Mail: E-Mail: Authorized Signature: Invoice Date and Number: Company Stamp: Delivery Date and Place: Authorized Signature: Company Stamp: PRODUCT Type: Warranty Time: Brand: Maximum Repair Time: Model: Banderole and Serial No: WARRANTY CONDITIONS...
Need help?
Do you have a question about the SOLIHP12INV-DF and is the answer not in the manual?
Questions and answers