Purpose
The AT-1I-DS temperature transducer has been designed for
temperature measurement using the DS1820 series digital tem-
perature sensor and converting measurement result into an ana-
log current signal in the range of 4÷20 mA.
Features
» Continuous measurement of ambient temperature using digi-
tal temperature sensors DS1820, DS18S20 and DS18B20 (sen-
sor to be purchased separately);
» Compatible with the RT4 temperature sensors (temperature
range -30÷65°C) manufactured by F&F;
» Adjustable measuring range;
» Optical indication of the operation of the transducer and the
state of the connected sensor.
F&F Filipowski L.P.
Konstantynowska 79/81, 95-200 Pabianice, POLAND
phone/fax (+48 42) 215 23 83 / (+48 42) 227 09 71
www.fif.com.pl; e-mail: biuro@fif.com.pl
- 1 -

Advertisement

loading

Summary of Contents for F&F AT-1I-DS

  • Page 1 Electro thrown in the trash or abandoned in nature, pose a threat to the environment and human health. Purpose The AT-1I-DS temperature transducer has been designed for temperature measurement using the DS1820 series digital tem- perature sensor and converting measurement result into an ana- log current signal in the range of 4÷20 mA.
  • Page 2: Front Description

    Front description Mounting Installation of the transducer should be performed by an installer with appropriate qualifications and experience in connecting electrical installations. It is recommended to use high quality power supplies with a good output voltage filtering ratio to power the transducer.
  • Page 3 Do not route signal cables, especially the cable for the temperature sensor, in parallel with other power cables. It is recommended to use a 3-core shielded cable to con- nect the temperature sensor. The shield of the cable on one side must be connected to PE. It is recommended to use a UTP twisted-pair cable to connect the power supply and the receiver.
  • Page 4 Power Maximum resistance of supply the receiver 375 Ω 12 V 500 Ω 24 V 1000 Ω 30 V 1200 Ω 4. Connect the temperature sensor to terminals 10-12 according to the color markings of the RT4 sensor, or the pinout of the DS1820 sensor.
  • Page 5: Wiring Diagram

    Wiring diagram 1 – power supply (+) 3 – current output 4÷20 mA 10 – temperature sensor [white] – power supply (–) 11 – temperature sensor [green] – data line (DATA) 12 – temperature sensor [brown] – power supply (+) - 5 -...
  • Page 6 Transduction characteristics The value of the output current depends on the current tempe- rature and the set measuring range. The shape of the characteristic is shown in the figure below: Incorrect configuration of the transducer or sensor fa- ilure is indicated by special output signal levels given in the table below: Level Description...
  • Page 7 LED signalling The operation of the transducer is indicated by the LED signal light located on the front of the device. Signal light Description The transducer and sensor are working properly Short blinks Incorrectly set measuring range every 1 second Rapid, frequent Sensor error (short circuit at the blinking...
  • Page 8: Warranty

    power consumption ≤0.6 W working temperature -25÷55°C terminal 2.5 mm² screw terminals tightening torque 0.4 Nm dimensions 1 module (18 mm) mounting on TH-35 rail ingress protection IP20 Warranty The F&F products are covered by a warranty of the 24 months from the date of purchase.