Page 1
Product Manual WDC-NX-BTD Handheld Bluetooth Device For use with the WDC-NX series Controller...
Page 2
• If the device, docking station or cables are damaged, they must be replaced by Wallgate, its service agents or similarly qualified persons to avoid hazard. Revision 1...
Every effort has been made to supply information within this manual which is correct. Wallgate Limited will not be liable for any damage or loss that arises if the person installing, operating, or maintaining the unit has not read or not complied with the manual.
Product Manual WDC-NX-BTD Washroom Remote Control 1.3 Note A note with amber text on a white background is used to draw your attention to important and useful information. NOTE: This is a note. 1.4 Numbered procedures Steps in procedures are numbered, starting from 1.
Page 6
WDC-NX-BTD WDC-NX-BTD is the model number of the Remote Washroom Device. SCAN The WDC-NX-BTD will search the local vicinity for any WDC-NX devices when the Scan is activated. UPLOAD LOGS This will store any logs retrieved from the WDC-NX devices into the Downloads folder on the WDC-NX-BTD device.
To benefit from the WDC-NX-BTD devices functionality and reliability it is best to use the following guidelines: • Maintain less than 10 metres from the WDC-NX controller.
Product Manual WDC-NX-BTD Washroom Remote Control 1.13 Power on the device • Press and hold the ‘ON’ button located at the top of the WDC-NX-BTD device until it vibrates. The screen should illuminate with the android logo. 1.14 Technical Specifications Table 2.
The WDC-NX-BTD device employs a capacitive touch screen for which navigation of the Washroom Remote Control application is used. The power button located at the top of the WDC-NX-BTD device is used to Power On/Off the device or if pressed momentarily and released it will switch off/on the display.
Product Manual WDC-NX-BTD Washroom Remote Control 3 Application Guide The remote washroom control is a device that connects to the Wallgate WDC-NX series of controller and allows the operator to perform a selection of operations. Launch the App Scan for...
Product Manual WDC-NX-BTD Washroom Remote Control Navigation settings from the Operations menu. Press the gear Back button to icon to access navigate back the area settings. to previous screen. Press the area navigation button to access its selection of settings.
Product Manual WDC-NX-BTD Washroom Remote Control Utility settings Setting In application identity Description Time slots Time slots for when the utility is available to use. Auto run Set a time to activate the utility cycle. Inactivity purge Set the length of time of inactivity before a purge is activated.
Product Manual WDC-NX-BTD Washroom Remote Control Discrete utility settings Utility Setting name Description WC Reduced The duration of the reduced flush. Min – 0.1 seconds Max – 3 seconds WC Full cycle period The duration of the full flush. Min – 0.1 seconds Max –...
Product Manual WDC-NX-BTD Washroom Remote Control Adjust settings from the Operations menu. Select the ‘Gear’ icon to access the settings for the utility. Select a setting to adjust. Save Change. Setting saved. Enter desired adjustment. Revision 1...
Product Manual WDC-NX-BTD Washroom Remote Control Adjust schedules from the Operations menu. Select the utility, then select one of the schedules ’Gear’ icon. Select the ‘Event Schedules’ to adjust. Adjust the time and Enable and Save Select a time slot.
Product Manual WDC-NX-BTD Washroom Remote Control Quick functions available Quick function Description Commission Purge Activate the commissioning purge for the room. The utilities will activate in order – 1. Cold Tap – 3 minutes 2. Hot Tap – 3 minutes 3.
Product Manual WDC-NX-BTD Washroom Remote Control Get logs from the Operations menu. Press the ‘GET Adjust ‘Number of Logs downloaded LOGS’ button. Log logs to request and into temporary Press ‘START count indicated in location. DOWNLOAD’ brackets ( ). Navigate with the Press ‘UPLOAD...
Product Manual WDC-NX-BTD Washroom Remote Control Log in (optional) As an additional option it is possible to add extra security to the access of the WDC-NX controllers. A log in to the WDC-NX controllers can be added which will be protected by a four-digit code for which the WDC-NX controller should have pre-programmed.
Product Manual WDC-NX-BTD Washroom Remote Control 3.2 Assign name to WDC-NX controller. Select the ‘Bluetooth Within settings, select Advertise Name’ the settings icon for the WDC-NX controller. Rename the controller The name of the to match the room WDC-NX controller name of where it is can be edited.
Product Manual WDC-NX-BTD Washroom Remote Control 3.3 Transfer logs to PC Connecting Device to PC Connect the USB cable to the USB C port on the underside of the docking station and feed the cable through the cable recess. Connect the USB A connector end to a PC USB port and house the device into the docking station.
‘File Explorer’ in the Windows Search (Bottom Left) and open the File Explorer. In the left-hand side column, locate ‘This PC’ and expand to locate either the DT50H device, or Wallgate Remote and expand to show ‘Internal shared storage’.
Product Manual WDC-NX-BTD Washroom Remote Control 3.4 Logs in Download folder. Once connected and powered on, the Windows File Explorer should automatically open displaying the ‘Internal shared storage’ for the Bluetooth device. Double click on the ‘Internal shared storage’ –...
Product Manual WDC-NX-BTD Washroom Remote Control 3.5 Log file details Column ID Description • Normal Activation – Any activation by the room Log ID occupier • System Activation – Any activation not activated by the room occupier – E.g. Hygiene Purge from the Remote device, or a times event ‘Auto-run’/’Inactivity Purge’.
Any service or repair work must be carried out by a qualified engineer. During the warranty period, the service or repair must only be done by a Wallgate engineer or appointed service agent. Refer to the Wallgate terms and conditions for warranty information.
1. How does the WDC-NX-BTD connect to the PC? • A docking station provided with the WDC-NX-BTD should be connected to the PC. Place the WDC-NX-BTD into the docking station.