70736 Fellbach Germany +49 711 51822 -0 met-info@otthydromet.com www.otthydromet.com All rights reserved. All content is the intellectual property of OTT HydroMet. Reprinting, duplication and translation (even as excerpts) are only permitted with the prior written consent of OTT HydroMet. Subject to technical change.
Table of contents Scope of supply Order numbers and variant code Product variants Accessories and spare parts 2.2.1 Accessories 2.2.2 Spare parts About this manual Other applicable documents and software General signs and symbols Explanation of warnings General safety instructions Intended use Potential misuse Personnel qualification...
Page 4
7.2.6 RS485 Interface 7.2.7 Connecting ISOCON-UMB converter 7.2.8 Installing surge protection Commissioning Set up device Configuration and testing 8.2.1 Factory settings Selecting device General settings Specific settings 8.5.1 Interval and temperature settings 8.5.2 Threshold settings Configuring IRS31-UMB compatibility mode 8.6.1 Example: Creating addresses Configuring coupling with ARS31 or ARS31Pro Testing...
2 Order numbers and variant code 2.1 Product variants Variant Order number IRS31Pro-UMB, 50 m cable length 8910.U050 IRS31Pro-UMB, 50 m cable length, 8910.U051 1 temperature depth sensor IRS31Pro-UMB, 50 m cable length, 8910.U052 2 temperature depth sensors IRS31Pro-UMB, 100 m cable length 8910.U100 IRS31Pro-UMB, 100 m cable length, 8910.U101 1 temperature depth sensor IRS31Pro-UMB, 100 m cable length, 2...
3 About this manual 3.1 Other applicable documents and software The following documents contain further information on installation, maintenance and calibration: – Operating Manual UMB ISO Converter ISOCON – Operating instructions surge protection The following documents and software can be downloaded at www.lufft.com: –...
3.3 Explanation of warnings To avoid personal injury and material damage, you must observe the safety information and warnings in the operating manual. The warnings use the following danger levels: WARNING WARNING This indicates a potentially hazardous situation. If the hazardous situation is not avoided, it may result in death or serious injuries.
4 Do not change or convert the product in any way. 4 Do not perform any repairs yourself. 4 Get OTT HydroMet to examine and repair any defects. 4 Ensure that the product is correctly disposed of. Do not dispose of it in household waste.
4.7 Working on roadways The device is installed in road- and runways. Special safety regulations apply to prevent accidents and injuries. 4 Observe the national and local safety regulations for construction work. 4.8 Certification 4.8.1 Europe, USA and Canada CE (EU) The equipment meets the essential requirements of RED Directive 2014/53/EU.
5 Product description 5.1 Design and function The passive intelligent road sensors are used for road weather monitoring. The device measures the surface temperature, water film height and salt concentration on the road. Thus the device can be used for the acquisition of a variety of measurement variables to determine the corresponding road conditions relevant for winter maintenance services.
6 Transport, storage, and unpacking 6.1 Unpacking 4 Carefully remove the product from the packaging. 4 Check that the delivery is complete and undamaged. 4 If you find any damage or if the delivery is incomplete, then immediately contact the supplier and manufacturer.
7 Installation 7.1 Mechanical installation 7.1.1 Preparing a site Special local, state or national regulations apply for working in and on roadways. Observe these regulations and prepare the intended installation area for the sensor accordingly . The device must be installed in the center of the road lane. On two-lane roads the device is installed in the left-hand lane.
4 For the device: mark and drill a hole with a diameter of 16 cm and depth of 6 cm into the road surface. 4 For the connection cable: cut a slit with the width of 2 cm and depth of 5 cm into the road surface. Optionally one or two temperature depth sensors are installed: One of the external temperature depth sensors is marked with a red cable flag, on which the intended installation depth is given.
4 Ensure that the cable connections are neither opened nor damaged. 4 Do not install the device with a damaged cable. 4 Have repairs carried out by OTT HydroMet service personnel. 4 Place the supply cable in a protective tube.
4 Avoid tensile stress on the cables. 7.2.2 Extending supply cable Shortening the supply cable is only permitted at the cabinet end of the cable. The loop impedance of the entire cable must not exceed 10 Ohm. 4 Shorten the original cable after the shortest possible distance (curbside 5 m). 4 Extend the cable by attaching an extension cable to the original cable.
RS485 termination resistance required means that a resistance of 120 Ohm should be connected parallel to the RS485 2-wire interface, either on the sensor inlet or sleeve. Recommended extension cable: A-2YF(L)2Y Nx2x0.8 or similar. Core pair 2x (2 times) means 2 pairs of wires, e.g. 2x2x0.8, because 2 individual wires are 1 pair for the power supply (+ and -). 7.2.3 Connecting power supply The road sensor supply cable is connected to the power supply in the control panel.
Page 18
Connection of color or numerically coded cables Pin assignment for external temperature sensors Number Color Assignment White External temperature sensor right 1 Brown External temperature sensor right 2 White External temperature sensor left 1 Brown External temperature sensor left 2 External temperature sensors (coding pin 1) Connection of color or numerically coded cables 7.2.4.1 Connecting devices in SDI-12 mode...
Power supply by the SDI-12 bus Number Color Assignment White SDI-12_GND Brown SDI-12 + 12 V Green Not connected Yellow SDI-12 signal Pin assignment: Supply voltage and SDI-12 The SDI12_GND is not attached to the earthing connection. 4 Connect the white, brown and yellow wires to the power supply unit. Isolated power supply Number Color...
+12V GND1 +24V GND2 Brown: positive supply voltage +12 V Green: RS485 interface A White: negative supply voltage GND1 Yellow: RS485 interface B 4 Connect the brown, white, green and yellow wires to the ISOCON-UMB converter. 4 Refer the operating manual UMB ISO converter ISOCON. 7.2.8 Installing surge protection The surge protection serves to protect the device against voltage spikes.
4 If several road sensors are operated on a UMB network, assign a unique device ID to each sensor. 8.2 Configuration and testing For configuration and testing OTT HydroMet Fellbach GmbH provides the proprietary software ConfigTool.NET. ConfigTool.NET can also be used to update the firmware of the device.
4 Confirm with Save/Exit. 8.4 General settings Parameter Description Device-ID Factory setting: 1 Assign the IDs for the devices in ascending order. Description To differentiate the devices enter a description, e.g. the location. Linespeed Transmission speed of the RS485 interface Factory setting: 19200 DO NOT change for operation with ISOCON-UMB.
8.5 Specific settings 8.5.1 Interval and temperature settings Parameter Description Measurement interval The sampling rate indicates how often a new measurement cycle is started. This value is configurable and can be set at 10, 20, 30 or 60 seconds. Factory setting: 10 seconds Number of samples for The number of measurements that are used to generate the moving average.
Parameter Description Freezing temperature This factor influences the calculation of the freezing temperature (non-linear). correction factor Factory setting: 1 A factor between 0 and 1 increases the freezing temperature. A factor greater than 1 reduces the freezing temperature. Example: Measured freezing temperature -7 °C; factor 0.5: freezing temperature -2.69 °C.
Parameter Description Limit [°C] for critical road Critical road conditions such as ice, wet/moist with salt can occur below this states threshold. Temperature limit for The freezing temperature is calculated when the measured road surface freezing temperature temperature is less than or equal to the set threshold temperature. calculations [°C] Factory setting: 4 °C Deicer...
When configuring a measurement station with IRS31-UMB sensors, the activation of the IRS31 compatibility mode should not cause double addressing. If necessary, change the ID. Parameter Description IRS31-UMB ID The ID of the IRS31-UMB sensor Class ID = 1 Number of samples for Number of measurements that are used to generate the moving average can be average configured.
– together the class and device ID gives address 9001h = 36865d Activating the compatibility mode changes the class ID to 1: – class ID for the IRS31Pro-UMB is 1 ( = 1h) – device ID is 1 ( = 1h) –...
Parameter Description Freezing temperature mode The use of the freezing temperature of an ARS31-UMB or ARS31Pro-UMB can be enabled or disabled. ARS31-UMB ID The ID of the ARS31-UMB or ARS31Pro-UMB sensor from which the freezing temperature channels are monitored. In default setting (= 0) all connected ARS31-UMB or ARS31Pro-UMB are evaluated. ARS31-UMB timeout Time after which a IRS31Pro-UMB resets a freezing temperature reported by the connected ARS31-UMB or ARS31Pro-UMB.
Page 29
4 Activate the desired channels. Channels for measurement polling The ConfigTool.NET software is provided for test and configuration purposes only. The tool is not suitable for the permanent acquisition of measurement data. For this purpose the use of professional software is recommended, e.g.
9 Maintenance 9.1 Maintenance schedule CAUTION Health hazard due to electromagnetic radiation! The device generates an electromagnetic field that can be harmful to health and can cause cardiac pacemakers to malfunction. 4 Disconnect the device from the power supply before working on it. The frequency of cleaning is dependent upon the local weather and environmental conditions.
9.3 Updating firmware The firmware can be updated with the ConfigTool.NET software. The firmware is valid for all types of the device. The description of the update can be found in the ConfigTool.NET software. 4 Download the latest version of the firmware and the ConfigTool.NET software: www.lufft.com/resources/. ®...
Device transmits error value – 4 Report any malfunction to the 32h (50d) representative of OTT HydroMet. Device transmits error value – 4 Report any malfunction to the 33h (51d) representative of OTT HydroMet.
Page 33
Device does not transmit the The sensor is dry – freezing temperature Device does not transmit the The sensor is covered with ice – freezing temperature Device transmits an unknown – 4 Report any malfunction to the error value representative of OTT HydroMet. <33>...
11 Repair 11.1 Customer support 4 Have repairs carried out by OTT HydroMet service personnel. 4 Only carry out repairs yourself if you have first consulted OTT HydroMet. 4 Contact your local representative: www.otthydromet.com/en/contact-us 4 Include the following information: – instrument model –...
In accordance with the German Electrical and Electronic Equipment Act (ElektroG; national implementation of EU Directive 2012/19/EU), OTT HydroMet takes back old devices in the Member States of the European Union and disposes of them in the proper manner. The devices that this concerns are labeled with the following symbol:...
13 Technical data 13.1 General technical data Intelligent road sensor Specification Value Protection class III (SELV) Protection type IP68 Operating temperature range -40 to +80 °C Humidity range 0 to 100 % Altitude above sea level 3000 m Storage temperature range (in -40 to +70 °C packaging) Humidity range (non-condensing, 0 to 95 % in packaging) External temperature depth sensor...
Specification Value Weight (without cable and Approx. 800 g without external temperature depth sensor) 13.4 Measuring range and accuracy Road surface temperature Specification Value Measurement process Measuring range -40 °C to +80 °C Resolution < 0.02 °C (-20 °C to +20 °C), otherwise +/-0.1 °C Accuracy +/-0.1 °C (-20 °C to +20 °C), otherwise +/-0.2 °C Sampling rate 10 sec to 60 sec...
Page 38
Specification Value Resolution 0.1 % Sampling rate 10 sec to 60 sec Units Saline concentration Specification Value Measurement process Passive Measuring range 0 to 100 % Resolution 0.1 % Accuracy (Wfh > 50 µm) 0 °C to -2.5 °C ( +/-0.5 °C), otherwise +/-20 % f. mv (with NaCl) Sampling rate 10 sec to 60 sec Units Friction...