HEAT RECOVERY UNIT
WENTILO ICON IC
User manual
MODELS:
IC120 S1 AA
IC180 S1 AA
IC120 S1 AB
IC180 S1 AB
IC120 E1 AA
IC180 E1 AA
IC120 E1 AB
IC180 E1 AB
IC120 S4 AA
IC180 S4 AA
IC120 S4 AB
IC180 S4 AB
IC120 E4 AA
IC180 E4 AA
IC120 E4 AB
IC180 E4 AB
rotenso.com
EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WENTILO ICON IC120 S1 AA and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Rotenso WENTILO ICON IC120 S1 AA

  • Page 1 IC180 S1 AB IC120 E1 AA IC180 E1 AA IC120 E1 AB IC180 E1 AB IC120 S4 AA IC180 S4 AA IC120 S4 AB IC180 S4 AB IC120 E4 AA IC180 E4 AA IC120 E4 AB IC180 E4 AB rotenso.com...
  • Page 3: Table Of Contents

    4.3 Cleaning the heat recovery unit housing  ���������������������������������������������������������������������������������������������  42 5. Faults and operating indications ................. 43 5.1 Faults without indication  ���������������������������������������������������������������������������������������������������������������������  43 5.2 Faults with indication  ��������������������������������������������������������������������������������������������������������������������������  43 6. Disposal and recycling ..................45 7. Technical specification   46 Rotenso Wentilo ICON IC120 | IC180  �������������������������������������������������������������������������������������������������������������  46...
  • Page 4: Basic Information

    1. Basic Information 1.1 General information This user manual is aimed at users of the Rotenso Wentilo ICON IC series heat recovery units. Please read the heat recovery unit user manual before using the unit. The latest version of the user manual is available at rotenso.com�...
  • Page 5: Precautions

    1.2 Precautions The safety precautions in the user manual must be strictly adhered to, as ignoring these instructions may result in death or serious injury. The precautions listed in the document are divided into the following categories. Read the instructions carefully before turning on the appliance.
  • Page 6 It is forbidden to modify or repair the unit yourself - only qualified installers are allowed to do this. CAUTION In order to use a Rotenso brand heat recovery unit safely, the installation should be carried out by a qualified installer. CAUTION It is forbidden to cover or reduce the cross-section of spigots connections�...
  • Page 7: Conditions Of Use

    1.3 Conditions of use The condensate generated by the heat transfer of the exhaust air is discharged into a condensate drain. The heat recovery unit must be installed in a room where the air Principle diagram of the counterflow exchanger for temperature is maintained between +5°C and +45°C.
  • Page 8: Scope Of Delivery

    The iCONNECT WEB service is available at wentilo.com� A full user Condensate drain manual for the iCONNECT application and iCONNECT WEB service is connection available at rotenso.com� Mounting template Appearance of the iCONNECT application icon Energy label 2. Switching the heat recovery unit on and off...
  • Page 9: Remote Control Of The Heat Recovery Unit

    3.2 Create user account in the iCONNECT 3.1 Remote control of the heat recovery unit mobile application iCONNECT The iCONNECT mobile application allows the installation to be added iCONNECT to a user account and allows the heat recovery unit connected to a The user can control the heat recovery unit using the iCONNECT WiFi network to be controlled.
  • Page 10: Iswitch Ti Control Panel

    3.3 iSWITCH Ti control panel ISWITCH Ti control panel Informations Indicator light Intensity when an alarm ventilation occurs Selection of one of three ventilation WiFi/BT intensity levels LED indicating network connection status WiFi or standard BT communication Manual Mode Switching to manual ON/OFF operation mode.
  • Page 11 Rotenso devices available nearby. Searching for and connecting Connecting to the panel to devices is only performed in the Standard for wireless BT communication� BT Connection BT Connection Configuration using the iCONNECT application The app uses BT or location services to search for an internet gateway devices.
  • Page 12 Preparing the phone for connection to iSWITCH Ti WiFi configuration The user should see the WiFi Configuration pop-up. Select Yes to start configuring the WiFi module of the iSWITCH Ti panel. iCONNECT PRO Enter the SSID of the WiFi network and the password with which the network is encrypted.
  • Page 13 PRO needs access to BT scanning functionality to find The application automatically detects the available devices - Rotenso surrounding BLE devices. control panels, acting as the internet gateway for the entire device. If there is no other active device of the same type and operating in...
  • Page 14 Choice of internet gateway Wentilo Installation Assistant Add Wentilo installation Device name: Internet gateway 1004778506 This guide will help you iCONNECT PRO create an account in wentilo.com service and successfully If an item with the corresponding SN number appears, it is add installation.
  • Page 15 Wentilo Installation Assistant - step 3 Create installation account Once the correct token has been entered, confirmation of correct registration will be displayed.. iCONNECT By accepting the OK tile, the first installation element will After logging in, the Installation selection window is appear.
  • Page 16: Adding An Installation Component

    3.3.3 Adding an installation component Wentilo Installation Assistant - step 7 Switching the panel to WiFi mode Once the iSWITCH Ti panel has been correctly configured as described in section 3.3.2 Adding the iSWITCH Ti panel to the user Add Wentilo installation account, the installation component (Wentilo heat recovery unit) can be added to the user account.
  • Page 17: Isense 5I Control Panel

    When the heat recovery unit is switched on, the start screen is 1005526401 initially displayed, where the button: 5.3 ºC 11.7 ºC Configure Installation list Supply temperature Exhaust temperature Home Takes you to the device configuration screen. Access protected by installer password. Devices parameters 22.5 ºC Chart...
  • Page 18 Creating an installation account Acceptance of consents BT Connection Add new instalation Choose how to add the installation: Device found 1005526425 Manual Next After logging in, the Choose installation window appears. Once the device has been selected, a new screen will appear Click the Add tile.
  • Page 19 Changing WiFi settings WiFi configuration WiFi configuration requires three steps: If you enter an incorrect network SSID or password, switch the panel to BT mode (see section Preparation of the iSENSE 5i panel). Switch the panel to WiFi mode by clicking the Mode tile until the WiFi option is highlighted.
  • Page 20: Adding An Installation Component

    Choice of installation name Token generation iCONNECT iCONNECT You must define the installation name that will be visible in Enter the Wentilo password, (token) and then click Accept� the iCONNECT mobile app and the iCONNECT WEB service. The token can be obtained by following the steps in the The name can be anything you like.
  • Page 21: Home Screen

    Information elements Completion of the contact information Once the installation components have been added to the User account, contact details can be completed to help identify the installation. Monday, 04.09.2023 Hint: Instalation name will be displayed on the top bar of In the top left corner of the screen you will find information the user application home screen, helping to identify the about the current temperature of the outdoor air sensor, the set...
  • Page 22 Main values tiles Schedule Schedule, in this mode the Fans operate according to a pre- programmed schedule, depending on the gears configured. Any Temperature room Intensity ventilation heat recovery unit flow rate can be assigned for a given gear. The centre of the display shows two main pieces of information about the operation of the heat recovery unit: room temperature Position two allows you to switch between the operating modes and ventilation intensity�...
  • Page 23: Menu

    9:09 23.1°C Kitchen hood Kitchen hood, mode allows the air extracted by the kitchen hood to be balanced, whereby the supply fan power is increased and the Intensity of inlet ventilation Extract fan flow rate is reduced to a user-set value. 320 m3/h 4000 3.4.5 Menu...
  • Page 24: Ventilation Intensity Schedule

    3.4.6.1 Ventilation intensity schedule Time interval edit Activate the interval (bottom right Active interval - set Ventilation intensity schedule screen to Yes). Once activated, the Begin, End and Ventilation Once the Ventilation intensity schedule has been selected, intensity options are unlocked. the user is redirected to a screen with a selection of days of the week, where individual ranges can be set by schedule for Set the start time of the interval by clicking the Begin...
  • Page 25 Gear editing Confirmation of the schedule for a particular day From the time interval screen, you can go to edit the When you have finished editing the schedule for a particular Ventilation intensity for a particular gear by clicking day, confirm the data you have entered with the Confirm the Gear editing button.
  • Page 26: Temperature Schedule

    Copying schedules Set the temperatures screen 9:09 23.1°C Schedules for each day are edited in the same way. If the schedules are the same for other days of the week, it is Monday, 04.09.2023 possible to copy the set schedule to other days. Start Return To do this, in the editing window of the set and saved schedule...
  • Page 27 Selection of days of the week Time reduction editing screen Once a time reduction has been selected an editing window When the Set the schedule tile is selected, the user is taken will be displayed. to a screen with a selection of days of the week, where different temperature setting can be specified for each day separately.
  • Page 28: Settings

    Example of a day with set time reduction Copying schedules Schedules for each day are edited in the same way. If the 9:09 23.1°C schedules are the same for other days of the week, it is Monday, 04.09.2023 possible to copy the set schedule to other days. To do this, in the editing window of the set and saved schedule Start Return...
  • Page 29 Date and time setting Screensaver Settings Screensaver screen Date and time screen The Screensaver screen opens by clicking the Screensaver The Date and time screen opens by clicking the Date and time tile on the Settings screen� tile on the Settings screen� The screen allows you to edit two parameters: The screen allows you to edit two parameters: Time...
  • Page 30 Display Settings Sounds off 9:09 23.1°C Display screen Monday, 04.09.2023 Start Return The Display screen opens by clicking the Display tile on the Settings screen� Sound The screen allows you to edit a single parameter: Screen brightness Alarm sounds - disabled 9:09 23.1°C Buttons sounds - disabled...
  • Page 31: Momentary Operation Modes

    WiFi settings Language settings WiFi settings screen Language screen The Language screen opens by clicking the Language tile 9:09 23.1°C on the Settings screen. Language is changed by clicking the appropriate tile. The tile with the currently selected language Monday, 04.09.2023 is highlighted.
  • Page 32 Airing Empty house Empty house screen Airing screen Empty house momentary operation modes can be activated Momentary operation mode Airing has 2 or 3 parameters, manually from the home screen or its activation can be depending on the settings made by the installer. scheduled using the Time mode tile�...
  • Page 33 Open window Airing activation When you click the Airing tile in the main window of momentary mode, the Airing window opens. Open window screen The Open window screen allows two parameters to be edited: 9:09 23.1°C Monday, 04.09.2023 Intensity of inlet ventilation, which determines the Start Reurn percentage of control at which the supply fan will operate...
  • Page 34 Fireplace Kitchen hood Fireplace screen Kitchen hood screen The Fireplace screen allows two parameters to be edited: The Kitchen hood screen allows three parameters to be edited: Increasing the intensity of the inlet air relative to extract Increasing the intensity of the inlet air, which determines the percentage of control that will be added to the current air, which determines the percentage of fan control that will be added to the current supply fan control during Fireplace...
  • Page 35: Complementary Devices

    3.4.9 Complementary devices Configuration with secondary heater ON, cooler ON and ground heat exchanger OFF. The Complementary devices screen, which is opened from the User 9:09 23.1°C menu, presents all available devices that support the maintenance of the comfort temperature but are not an integral part of the heat Monday, 04.09.2023 recovery unit, including: Start...
  • Page 36: Advanced

    Start Return Once accepted, the Advanced settings menu screen will be displayed. Order filters 9:09 23.1°C Device model AHU_NAME Monday, 04.09.2023 Go to the store rotenso.com/shop Start Return Advanced settings Filters Auto mode Service Control Bypass Drainage exchanger seasonal Filter replacement procedure...
  • Page 37 follow the steps in that manual, and then return to the completed. After confirmation the heat recovery unit will control panel. automatically return to normal operation. When the filter replacement is complete, the Days left to replace filters tile will be displayed. After clicking it Auto mode you can set the time after which the heat recovery unit will signal the need to replace the filters.
  • Page 38 Exchanger drainage Edit parameters Settings are changed by clicking the relevant tile and then using the + and - buttons or by clicking the value axis to set Exchanger drainage screen the desired value. The change is confirmed The Exchanger drainage screen opens by clicking the with the Confirm button.
  • Page 39: Maintenance

    4. Maintenance Turn off the device 4.1 Air filter replacement NOTE Regardless of the version of the heat recovery unit assembly, filter replacement operations are carried out in the same way as described below. Switch the power button to the position �...
  • Page 40 The arrows printed on the Filters must point in line with the Installation of new filters into the heat recovery unit housing arrows on the heat recovery unit housing. for the Standard (A) version MARK FILTER NAME iCARE G4 COARSE 75% iCARE F7 ePM1 70% iCARE M5 ePM10 55% Insert new anti-pollen filter iCARE G4 COARSE 75%�...
  • Page 41: Heat Exchanger Cleaning

    Installation of the decorative cover Removal of heat exchanger cover bolts Fit the decorative cover to the mounting pins. Using a 3 mm allen key, unscrew the 6 bolts securing the exchanger cover. Secure all screws for reassembly. 4.2 Heat exchanger cleaning Removal of heat exchanger cover Check the cleanliness of the heat exchanger once a year.
  • Page 42: Cleaning The Heat Recovery Unit Housing

    Wash the exchanger according to the following steps: Securing heat exchanger cover Insert the exchanger into the tank (i.e. bathtub). Rinse the exchanger with clean water. Pour the soap solution into the bottom of the container. Using a small container, pour the solution into all the channels of the heat exchanger.
  • Page 43: Faults And Operating Indications

    5. Faults and operating indications 5.1 Faults without indication The table shows possibly occurring faults without indication on the display and their description and solution. FAULT CAUSE SOLUTION Heat recovery unit is not plugged in Insert the power cord plug of the appliance into the socket Device does not switch on The power button under the decorative cover is in the Switch the power button to the ''I'' position...
  • Page 44 cont. 5.2 Faults with indication ALARMS POSSIBLE CAUSE ALARM SIGNAL DISPLAY A low temperature or signal from the secondary heater thermostat of the Alarm signalling, ALARM output active, Active Secondary heater thermostat. Continuously since the cause was noted. Warm-up procedure. water heater was noted - the warm-up warm-up procedure.
  • Page 45: Disposal And Recycling

    ALARMS POSSIBLE CAUSE ALARM SIGNAL DISPLAY Error in communication between Alarm signalling, Communication error from supply control panel and supply air pressure ALARM output active, air pressure sensor/flow sensor for Continuously since the cause was noted. sensor Possible damage to or further heat recovery unit operation.
  • Page 46: Technical Specification

    7. Technical specification Rotenso Wentilo ICON IC120 | IC180 IC120 E1 AA IC120 E4 AA IC120 S1 AA Parameter Unit IC120 E1 AB IC120 E4 AB IC120 S1 AB Specific energy consumption (cold zone) kWh/(m² x a) -70.2 -78.6 -75.0...
  • Page 47 Control panel with screen: highlighted notification icon and text information. Mobile application: text notification. Web application: text notification. Regular filter changes guarantee correct operation of the unit. Extensive clogging of filters decreases energy efficiency of the unit and increases noise level. rotenso.com rotenso.com rotenso.com rotenso.com rotenso.com 217.8...
  • Page 48 NOTEBOOK...
  • Page 50 Thermosilesia Sp. z o.o. Sp.k ul. Szyb Walenty 16 41-700 Ruda Śląska...

This manual is also suitable for:

Wentilo icon ic180 s1 aaWentilo icon ic120 s1 abWentilo icon ic180 s1 abWentilo icon ic120 e1 aaWentilo icon ic180 e1 aaWentilo icon ic120 e1 ab ... Show all

Table of Contents