Gima AGS-PL100 Manual
Gima AGS-PL100 Manual

Gima AGS-PL100 Manual

Portable led light source 200.000 lux

Advertisement

Quick Links

PROFESSIONAL MEDICAL PRODUCTS
FONTE DI LUCE LED PORTATILE
200 . 000 LUX
PORTABLE LED LIGHT SOURCE
200 . 000 LUX
- È necessario segnalare qualsiasi incidente grave verificatosi in rela-
zione al dispositivo medico da noi fornito al fabbricante e all'autori-
tà competente dello Stato membro in cui si ha sede.
- All serious accidents concerning the medical device supplied by us
must be reported to the manufacturer and competent authority of
the member state where your registered office is located.
AGS-PL100 (GIMA 30796)
Wuzhou Aokace Tecnology Co . , Ltd
Building 10, Yingtian Industrial Park, High-tech
Industrial Development Zone,
Wuzhou Guangxi, China - Made in China
Sungo Europe B . V .
Fascinatio Boulevard 522, Unit 1 . 7 - 2909VA
Capelle aan den IJssel
The Netherlands
Importato da / Imported by
Gima S . p . A .
Via Marconi, 1 - 20060 Gessate (Mi) - Italy
gima@gimaitaly . com - export@gimaitaly . com
www . gimaitaly . com
80%
+55˚C
%
-20˚C
10%

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AGS-PL100 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Gima AGS-PL100

  • Page 1 Fascinatio Boulevard 522, Unit 1 . 7 - 2909VA Capelle aan den IJssel The Netherlands Importato da / Imported by Gima S . p . A . Via Marconi, 1 - 20060 Gessate (Mi) - Italy gima@gimaitaly . com - export@gimaitaly . com www . gimaitaly . com +55˚C...
  • Page 2: Main Parameters

    ENGLISH AGS-PL100COLDLIGHTSOURCE Instruction Manual You must use a network outlet with a protective grounding wire and ensure a good grounding. Do not alter this device without authorization from the manufacturer. Overview The cold light source for endoscopy is mainly composed of LED cold light source, control circuit and battery, which can be connected with endoscope through optical fiber for clini- cal endoscopy or deep surgical illumination, etc.
  • Page 3: Structure And Principle

    Battery LED Bulb Control Scopes of Application and Contraindications AGS-PL100 cold light source for endoscope has low power consumption, high efficiency, stable performance and long service life. Scope of application: It can be connected with endoscope through light guide bundle for clinical endoscopy or deep surgical illumination, etc.
  • Page 4 ENGLISH  Fiber optic cable can not be too curved, and the radius of curvature should not beless than 5CM, otherwise it will break the fiber optic cable, affecting the lightrate.  Before each use,the user must check whether there is any rough surface, sharpedges or protrusions on the endoscope, especially the part inserted intohuman body, which would cause safety hazards probably.
  • Page 5: Electromagnetic Compatibility

    DC3.7V cylindrical 18650 lithium battery charger that meets the local standard. Electromagnetic Compatibility Caution:  AGS-PL100 cold light source for endoscope meets the YY0505-2012 standard on electromagnetic compatibility requirements.  The user should install and use the device according to electromagnetic compatibility information offered in the instruction.
  • Page 6 Attachment: Guidance and manufacturer's statement - Electromagnetic emission AGS-PL100 cold light source for endoscope is expected to be used in the following specified electromagnetic environment, the user should ensure the device is used in this electromagnetic environment: Emissio Test Compliance...
  • Page 7 Note: U refers to the AC voltage before applying the test voltage. Guidanceandmanufacturer’sstatement-Electromagneticimmunity AGS-PL100 cold light source for endoscope is expected to be used in the following specified electromagnetic environment, users should ensure the device is used in this electromagnetic environment...
  • Page 8 GB/ 150kHzto80 nication equipment as well as T17625.6 cables should not be used more closely to any parts of AGS-PL100 cold light source for endoscope than the recommended isolation distance. The distance should be calculated by the formula corresponding to the transmitter frequency.
  • Page 9 Recommended isolation distance between portable and mobile RF communication equipment and AGS-PL100 cold light source for endoscope. AGS-PL100 cold light source for endoscope is expected to be used in radiated RF harassment controlled electromagnetic environmen- ts. According to the maximum output power of the communication...
  • Page 10 ENGLISH Instructions for use 1. Description Dust Cover Light Source Connector Lens Barrel Battery Cartridge Tail Cap Configuration diagram Fiber Optic Adapter 1 Fiber Optic Adapter 2 Fiber Optic Adapter 3 Switch...
  • Page 11 ENGLISH Cold light source and light guide bundle connection sche- matic LED cold light source structure diagram Ø25 2. Installation Take out the cold light source and battery from the box, loo- sen the tail cap, put the battery into the battery barrel when positive pole facing forward and then put back the tail cap.
  • Page 12: Maintenance And Cleaning

    ENGLISH Maintenance and Cleaning 1. Use hydrogen-containing disinfectant to clean the outsi- de of the equipment. 2. To keep the system clean, gently wipe the surface of the equipment with a soft damp cloth (gauze) that is warmed by warm water or that is with a cleaning agent. The cle- aning should be at least once a month, and should avoid liquid infiltration into the cold light source.
  • Page 13 Disposal: The product must not be disposed of along with other domestic waste. The users must dispose of this equipment by bringing it to a specific recycling point for electric and electronic equipment. GIMA WARRANTY TERMS The Gima 12-month standard B2B warranty applies.