NSS 100
single use condensate cleaner
Installation Manual
Installation
2
Fix the wall plate vertically on a
suitable wall or the compressor
cabinet. Isolate the compressor
and look out for cables and pipes
when drilling.
IMPORTANT - Always use an automatic drain. Set timers to short open periods of one second or less.
6
NEVER use manual drains which could flood the separator, forcing partially treated or untreated condensate to be discharged.
3
Slide the NSS 100 on to the
plate, with the venting flutes at
the top.
Before starting assembly, please read
1
the following:
NSS 100 is a single-use product. It should be
replaced as directed to ensure its vital
environmental and legally protective functions are
performed correctly.
NSS 100 has been designed to clean condensate from
a compressor system of up to 102 m
10 ppm oil-in-water; suitable for discharge to a sewer.
NOTE: This is generally well below the
accepted level, but it is the users responsibility to
ensure compliance with local regulations.
Top Inlet Port
The unit comes shipped with a
6mm inlet port as standard
8mm
Other size inlet ports are available as shown above.
Please specify when ordering.
4
inlet
Connect all drain points, insert
tube into push fitting in the inlet
(top).
6 mm tube for metric
¼" tube for imperial
h to better than
3
1/4"
5/16"
5
anti-siphon vent
(do NOT block)
outlet
Connect tube into outlet fitting
and feed to drain (side). Ensure
a steady fall from outlet point to
drain with no kinks or tight
bends.
10 mm tube for metric
a" tube for imperial