Download Print this page

Elektor S-HE Operating And Assembly Instruction Manual

High effi ciency blower

Advertisement

Available languages

Available languages

Quick Links

Betriebs- und Montageanleitung
Operating and assembly instructions
S-HE 340/85-50/1,5, S-HE 340/85-60/1,5
S-HE 370/95-50/2,2, S-HE 370/95-60/2,2
S-HE 380/95-50/2,2, S-HE 380/95-60/2,2
S-HE 420/105-50/3,0, S-HE 420/105-60/3,0
S-HE 430/105-50/4,0, S-HE 430/105-60/4,0
S-HE 470/120-50/5,5, S-HE 470/120-60/5,5
S-HE 480/120-50/7,5, S-HE 480/120-60/7,5
S-HE 530/135-50/11,0, S-HE 530/135-60/11,0
S-HE 540/135-50/15,0, S-HE 540/135-60/15,0
S-HE
Hocheffi zienzventilator
High effi ciency blower
www.elektror.com
DE
EN

Advertisement

loading
Need help?

Need help?

Do you have a question about the S-HE and is the answer not in the manual?

Questions and answers

Summary of Contents for Elektor S-HE

  • Page 1 S-HE Hocheffi zienzventilator Betriebs- und Montageanleitung High effi ciency blower Operating and assembly instructions S-HE 340/85-50/1,5, S-HE 340/85-60/1,5 S-HE 370/95-50/2,2, S-HE 370/95-60/2,2 S-HE 380/95-50/2,2, S-HE 380/95-60/2,2 S-HE 420/105-50/3,0, S-HE 420/105-60/3,0 S-HE 430/105-50/4,0, S-HE 430/105-60/4,0 S-HE 470/120-50/5,5, S-HE 470/120-60/5,5 S-HE 480/120-50/7,5, S-HE 480/120-60/7,5...
  • Page 2 Betriebs- und Montageanleitung S-HE Bei Betrieb mit aggressiven oder sehr feuchten Medien ist INHALT eine Ausführung in Edelstahl (1.4301) möglich. Die Bestän- digkeit ist vom Betreiber zu prüfen. ANGABEN ÜBER DIE MASCHINE Bei Kondensatbildung empfehlen wir eine Kondenswasser- bohrung an der tiefsten Stelle im Gehäuse.
  • Page 3 Betriebs- und Montageanleitung S-HE 1.5 Ansaugwirkung 1.9 Geräuschentwicklung Hinweis! Warnung! Tragen Sie, ab einem Tagesexpositionspegel von Verletzungsgefahr durch Ansaugwirkung! 80 dB(A) und/oder einem Spitzenschalldruckpe- Am Ansaugstutzen können Gegenstände, Klei- gel von 135 dB(C), einen Gehörschutz während dung, wie auch Haare angesaugt werden.
  • Page 4 Betriebs- und Montageanleitung S-HE 1.12 Zulässige Einbaulagen Hebeposition Hinweis! Die Befestigung am Ventilator ist nur über eine feste Anbindung zulässig! Kompensatoren nicht als feste Anbindung ver- wenden! Hinweis! Hinweis! Einbaulagen mit senkrechter Antriebswelle hal- Einbaulagen mit senkrechter Antriebswelle hal- bieren die Lebensdauer der Kugellager.
  • Page 5 Betriebs- und Montageanleitung S-HE • Der Schutzleiteranschluss ist im Klemmenkasten vorhanden. Messung am Flanschlagerschild, möglichst in Lager- nähe Hinweis! Bei Betrieb des Antriebsmotors mit Frequenzum- richter ist zusätzlich folgendes zu Beachten: • Es dürfen nur Motoren am Frequenzumrichter betrieben werden die mit der Option „/FU“, für den „Frequenzumrichterbetrieb geeignet“...
  • Page 6 Betriebs- und Montageanleitung S-HE 3.3.1 Schaltung für Drehstrom-Ventilatoren Motoren, FU Motoren und sonstige Sonderverschaltungen von Dreh- und Wechselstrommotoren liegen im Klemmen- Warnung! kasten der Motoren Anschlusspläne der Lieferung bei. Das Gefahr durch lose und falsch angezogene gilt auch für den optionalen thermischen Wicklungsschutz Verbindungen! und die Stillstandsheizung.
  • Page 7 Betriebs- und Montageanleitung S-HE Nach Schutzabschaltungen, wie z.B. Auslösen des Motor- ßen. Einphasen-Wechselstrommotoren sind für schutzschalters, Ansprechen des PTC-Auswertegerätes Umrichterbetrieb nicht geeignet. Die vom Liefe- bei Motoren mit Kalteiterfühler oder Schutzabschaltung des ranten des Frequenzumrichters in den jeweiligen Frequenzumrichters bei FU-Anwendungen, ist ein Neustart Bedienungs- oder Applikationshandbüchern be-...
  • Page 8 Betriebs- und Montageanleitung S-HE Maßnahmen zur, sowie Wartung und Instandhaltung selbst, Stellen Sie ebenfalls sicher, dass keine Gefährdungssitu- dürfen nur von ausreichend sach- und fachkundigen, regel- ation in Folge eines Wiederanlaufes nach einem Stillstand mäßig geschulten Personen ausgeführt werden. Dabei ist entsteht, z.B.
  • Page 9 Maschinen (2006/42/EG) entspricht. Beschreibung der unvollständigen Maschine: Hocheffi zienzventilatoren S-HE 340/85-50/1,5, S-HE 340/85-60/1,5, S-HE 370/95-50/2,2, S-HE 370/95-60/2,2, S-HE 380/95-50/2,2, S-HE 380/95-60/2,2, S-HE 420/105-50/3,0, S-HE 420/105-60/3,0, S-HE 430/105-50/4,0, S-HE 430/105-60/4,0, S-HE 470/120-50/5,5, S-HE 470/120-60/5,5, S-HE 480/120-50/7,5, S-HE 480/120-60/7,5, S-HE 530/135-50/11,0, S-HE 530-60/11,0, S-HE 540/135-50/15,0, S-HE 540/135-60/15,0 Serien-Nummer und Baujahr sind dem Gerätetypenschild und dem zugehörenden Lieferschein zu entnehmen.
  • Page 10: Table Of Contents

    Operating and assembly instructions S-HE steel (1.4301) can be used for operation with aggressive or CONTENTS very humid media. The operator must check the resistance. We recommend a condensed water borehole at the lowest MACHINE SPECIFICATIONS point in the housing in the event of the formation of conden- sation.
  • Page 11 Operating and assembly instructions S-HE 1.5 Suction eff ect 1.9 Noise emission Note! Warning! Wear hearing protection during operation at a Risk of injury due to suction eff ect! daily exposure level of 80 dB(A) and above, and/ Objects, clothing and hair can be sucked in at the or a peak sound pressure level of 135 dB(C) and intake port.
  • Page 12: Information On Transport, Handlng And Storage Of The Machine

    Operating and assembly instructions S-HE 1.12 Allowed mounting positions Lifting position Note! Fastening to the fan is only permitted via a fi xed connection! Do not use expansion joints as a fi xed connec- tion! Note! Installation positions with a vertical drive shaft halve the life of the ball bearings.
  • Page 13 Operating and assembly instructions S-HE • Check that the mains voltage matches the ratings on the Measurement at the fl ange bearing shield, preferably motor nameplate. near the bearing • The safety earth terminal can be found in the terminal box.
  • Page 14: Instructions For Operation And Use

    Operating and assembly instructions S-HE personal injuries! 3.5 Declaration concerning the EMC Directive (2014/30/EU) Check for loose connections and tighten in Our blowers are components that are designed to be in- accordance with the tightening torques in the fol- stalled in other machines or systems by qualifi ed personnel, lowing table.
  • Page 15: Instructions For Maintenance

    Operating and assembly instructions S-HE resistance is too low (excessive current consumption). The ing output on the cooling fi ns is not adequate. Regular cleaning is required for devices in these volumetric air fl ow should be reduced in this case by means of a throttle valve fi...
  • Page 16: Safety Related Information On Taking Out Of Operation And Removal

    Operating and assembly instructions S-HE Note! 6 SAFETY RELATED INFORMATION Repairs must be carried out by the manufacturer. ON TAKING OUT OF OPERATION AND We cannot accept any liability for repairs carried out by third parties. REMOVAL 5.1 Ball bearings...
  • Page 17: Declaration Of Incorporation According To Appendix Ii 1 B

    EC) as set forth below. Description of incomplete machine: High Effi ciency Blower S-HE 340/85-50/1,5, S-HE 340/85-60/1,5, S-HE 370/95-50/2,2, S-HE 370/95-60/2,2, S-HE 380/95-50/2,2, S-HE 380/95-60/2,2, S-HE 420/105-50/3,0, S-HE 420/105-60/3,0, S-HE 430/105-50/4,0, S-HE 430/105-60/4,0, S-HE 470/120-50/5,5, S-HE 470/120-60/5,5, S-HE 480/120-50/7,5, S-HE 480/120-60/7,5, S-HE 530/135-50/11,0, S-HE 530-60/11,0, S-HE 540/135-50/15,0, S-HE 540/135-60/15,0 Serial number and year of manufacture can be found on the device nameplate and on the accompanying delivery slip.
  • Page 18 www.elektror.com...
  • Page 19 www.elektror.com...
  • Page 20 www.elektror.com...
  • Page 21 www.elektror.com...
  • Page 22 www.elektror.com...
  • Page 23 www.elektror.com...
  • Page 24 www.elektror.com...
  • Page 25 www.elektror.com...
  • Page 26 Elektror airsystems gmbh Hellmuth-Hirth-Str. 2 73760 Ostfi ldern Telefon: +49 711 31973-0 info@elektror.de www.elektror.com...