Page 3
PARTS REQUIRED LP-0.9M FPA (FIREFIGHTERS POLE) LP-1.2M LCPT - 93 SCT - STANDRAD CASTLE TRIM CPT-143 FIREFIGHTERS POLE REF: CAS103 pg 3 of 23 06.10.22...
Page 4
PARTS REQUIRED CASTLE WALKWAY PANELS / TIMBERS TIMBER SLATS (JIG208-B) JIG208-A FLOOR ASSEMBLY JIG208-C ICPR-912 - RIGHT PANEL ICPR-912 - LEFT PANEL ICPR-912 - MIDDLE PANEL REF: CAS103 pg 4 of 23 06.10.22...
Page 5
PARTS REQUIRED .inc standard fixings x1 .inc standard fixings JIGSAW STANDARD PART JIGSAW STANDARD PART JIG916 - RUNG LADDER 0.9M JIG102 - GUARD RAIL STRAIGHT CNC - CASTLE NET CROSSING X1 .inc standard fixings .inc standard fixings JIGSAW STANDARD PART JIGSAW STANDARD PART JIG1213 - RAMP - 1.2M JIG1211 - SLIDE - 1.2M...
Page 6
PARTS REQUIRED - CASTLE UPRIGHT TIMBERS CAS103-U1.2 CAS103-U1.2 CAS103-U1.2 CAS103-U1.2 CAS103-U1.2 CAS103-U0.9 CAS103-U1.2 CAS103-U1.2 CAS103-U1.2 CAS103-U0.9 CAS103-U0.9 CAS103-U0.9 x12 (8 X 1.2 / 4 X 0.9) CAS103-U1.2 / U0.9 ADDITIONAL CODE TYPE SIZE INFORMATION UPRIGHTS CAS103-U1.2 90x90 3750* (ADD 150MM EXTENSION) CAS103-U0.9 90X90 3450...
INSTALLATION INSTRUCTIONS ATTACH FLOOR ASSEMBLY TO UPRIGHT TIMBERS - SEE NEXT PAGE USING 274.M12X180 / 656.M12 / 102003-01 - QUANTITY X 4 NOTES: NYLOC & COVERED END ARE ALWAYS POSITIONED ON THE INSIDE PLEASE NOTE - END CAPS MAY NOT BE REQUIRED SOME ATTACHMENT PARTS MEANS END CAPS ARE NOT REQUIRED NOTES: TIMBER SUPPORT IS CUT TO FIT AROUND THE NYLOC - CIRCLED ABOVE...
Page 11
INSTALLATION INSTRUCTIONS ENSURE COUNTERSUNK HOLES ARE AS SHOWN DIRECTION OF HOLES HIGHLIGHTED BELOW ATTACH THE CASTLE WALKWAY FLOOR ATTACH USING 97.M8X180CSK 97.M8X180CSK REF: CAS103 pg 11 of 23 06.10.22...
Page 12
INSTALLATION INSTRUCTIONS ATTACH THE 90X90 TIMBERS TO BOTH SIDES OF FLOOR ASSEMBLY USING M8X120MM WOOD SCREWS, ENSURE IT IS SCREWED IN FROM INSIDE OF FLOOR ASSEMBLY NOTES: ENSURE 90X90 TIMBERS SITS BELOW THE HEXAGRIP FLOOR AND IS FLUSH WITH THE OUTER FACES OF JIGSAW UPRIGHT TIMBERS 8X M8X120MM SCREWS - SCREW THROUGH TO 90X90 TIMBER ATTACH HAND RAILS TO JIGSAW PLATFORM UPRIGHT TIMBERS...
Page 13
INSTALLATION INSTRUCTIONS ATTACH GUARD RAIL SLATS TO BOTH THE HANDRAIL AND 90X90 TIMBER USING 4X M6X40MM WOOD SCREWS PER SLAT, SECURED AT DIMENSIONS SHOWN BELOW ON BOTH SIDES HAND RAIL ***HANDRAIL - ONE SIDE ONLY*** 90X90 TIMBER ENSURE THE WALKWAY IS AS SHOWN BELOW CUT OUT SECTIONS OF THE FLOOR AS CIRCLED REF: CAS103 pg 13 of 23 06.10.22...
Page 14
INSTALLATION INSTRUCTIONS POSITION THE WALKWAY ADDITIONAL UPRIGHT TIMBERS 750MM DEEP FOUNDATION REQUIRED (400MM X 400MM) ATTACH HAND RAILS TO JIGSAW PLATFORM UPRIGHT TIMBERS USING M8X180MM WOOD SCREWS, 4X PER SIDE OF PANEL AS SHOWN NOTES: ENSURE PANELS AR FLUSH WITH THE TOP OF THE UPRIGHT TIMBER AND IN LINE / LEVEL WITH THE HANDRAIL TIMBER OPPOSITE SIDE REF: CAS103...
Page 15
INSTALLATION INSTRUCTIONS POSITION ALL LOWER CLADDING PANELS LP-1.2M LP-1.2M LP-1.2M LP-1.2M LP-1.2M ATTACHING LOWER CLADDING PANELS... USING 6X M8X180MM WOOD SCREWS - 3 PER SIDE, SCREW IN FROM INSIDE OF TOWER AS SHOWN BELOW NOTES: LOWER PANELS MUST SIT BELOW PLATFORM 90X90 TIMBERS (SEE DOTTED LINE) ENSURE PANELS SIT FLUSH WITH UPRIGHT PLANE FACES...
Page 16
INSTALLATION INSTRUCTIONS POSITION ALL UPPER CLADDING PANELS ATTACH UPPER CLADDING PANELS... USING 8X M8X180MM WOOD SCREWS - 4X PER SIDE FOR EACH PANEL IN LOCATIONS SHOWN NOTES: UPPER PANELS MUST SIT ON TOP OF PLATFORM HEXAGRIP (SEE DOTTED LINE) ENSURE PANELS SIT FLUSH WITH UPRIGHT PLANE FACES REF: CAS103 pg 16 of 23 06.10.22...
Page 17
INSTALLATION INSTRUCTIONS POSITION REMAINING UPPER AND LP-1.2M CLADDING PANELS USING 16X M8X180MM WOOD SCREWS LP-1.2M INSTALL NET CROSSING UPRIGHT TIMBERS ENSURE THE HOLES ARE IN THE DIRECTION SHOWN NOTES: *ICPR-912a SITS AT 1980MM FROM GROUND LEVEL *ICPR-912b SITS AT 1850MM FROM GROUND LEVEL REF: CAS103 pg 17 of 23 06.10.22...
Page 18
INSTALLATION INSTRUCTIONS INSTALL THE ICPR PANELS (LEFT / MIDDLE / RIGHT) USING 22X M8X180MM WOOD SCREWS ICPR-912 (LEFT) ICPR-912 (MIDDLE) ICPR-912 (RIGHT) NOTES: ENSURE MIDDLE PANEL IS POSITIONED AT DIMENSION SHOWN, ALL PANEL FRAMES MUST BE IN-LINE (SEE DOTTED LINE) ATTACH NET CROSSING PRE-ASSEMBLY TO ICPR PANELS USING SOCKET NUTS &...
Page 19
INSTALLATION INSTRUCTIONS ATTACH FPA CLADDING PANEL & LP-0.9 USING 8X M8X180MM WOOD SCREWS - 4X PER SIDE (PER PANEL) LP-0.9 ATTACH FIREMANS POLE TO FPA PANEL AT DIMENSIONS SHOWN USING 2X M8X80MM WOOD SCREWS NOTES: FIREFIGHTERS POLE MUST SCREW THROUGH THE PANEL INTO THE 90X90 TIMBER SUPPORT REF: CAS103 pg 19 of 23 06.10.22...
Page 20
INSTALLATION INSTRUCTIONS ATTACH SA PANELS TO TOP OF TOWERS AT DIMENSIONS SHOWN USING 6X M8X180MM WOOD SCREWS - 2X PER SIDE FOR EACH PANEL IN LOCATIONS SHOWN NOTES: SA PANELS MUST SIT FLUSH WITH TOP OF UPRIGHT TIMBER - NOT END CAPS! (SEE DOTTED LINE) ATTACHING SCT TURRET TRIP PIECES, SEE NEXT STEP FOR LOCATIONS...
Page 21
INSTALLATION INSTRUCTIONS ATTACH SCT TRIM PIECES TO BOTH TOWERS POSITION AND ATTACH AS DESCRIBED ON PREVIOUS STEP INSTALL STANDARD JIGSAW PARTS IN LOCATIONS SHOWN USING STANDARD JIGSAW INSTRUCTIONS & FIXINGS JIG1212 - RAMP - 1.2M PLATFORM JIG1211 - SLIDE - 1.2M PLATFORM JIG102 - GUARD RAIL STRAIGHT JIG916 - RUNG LADDER- 0.9M PLATFORM REF: CAS103...
Page 22
INSTALLATION INSTRUCTIONS ATTACH CPT-143 & LCPT-93 TRIM PIECES TO TOWERS IN LOCATIONS SHOWN POSITION AND ATTACH AS DESCRIBED ON NEXT STEP LCPT-93 CPT-143 CPT-143 CPT-143 CPT-143 CPT-143 ATTACHING CPT CENTRE TRIM PIECES USING 4X M8X80MM WOOD SCREWS - 2X PER SIDE FOR EACH PANEL - SCREW INTO UPRIGHTS UPPER = ABOVE HEXAGRIP FLOOR LOWER = BELOW PLATFORM 90X90’S GAPS BETWEEN UPPER AND LOWER PANELS MUST LOOK...