  • Page 1 DAQP-HV TECHNICAL REFERENCE EN ISO 14001 ISO 9001...
  • Page 2 Copyright © DEWETRON GmbH This document contains information which is protected by copyright. All rights are reserved. Reproduction, adaptation, or translation without prior written permission is prohibited, except as allowed under the copyright laws. All trademarks and registered trademarks are acknowledged to be the property of their owners.
  • Page 3: Preface

    Thank you! Thank you very much for your investment in DEWETRON‘s unique data acquisition systems. These are top-quality inst- ruments which are designed to provide you years of reliable service. This guide has been prepared to help you get the most from your investment, starting from the day you take it out of the box, and extending for years into the future.
  • Page 4: Table Of Contents

    TABLE OF CONTENTS Table of contents Preface ..........3 Maintenance and service ....16 Thank you! ............3 Service interval ...........16 Cleaning ..............16 Service and repairs ..........16 Safety ..........5 Calibration ............17 Safety instructions ..........5 Support ...............17 General safety instructions ........ 5 Training ...............17 Electrical safety instructions ......
  • Page 5: Safety

    Because of the danger of introducing additional hazards, do not install substitute parts or perform any unauthorized modification to the product. Return the product to a DEWETRON sales and service office for service and repair to ensure that safety features are maintained.
  • Page 6: Electrical Safety Instructions

    Safety ` Contact a professional if you have doubts about the method of operation, safety or the connection of the system. ` Handle the product with care. Shocks, hits and dropping it even from an already lower level may damage your system.
  • Page 7: Safety Notices During Operation

    ` Do not use the system in rooms with flammable gases, fumes or dust or in adverse environmental conditions. ` Direct exposure of any DEWETRON product to strong sunlight or other heat radiation shall be prevented, as this could excessively heat up the product and lead to permanent damage of the product.
  • Page 8: Notices

    Safety Notices NOTICE This text indicates situations or operation errors which could result in property damage or data loss. INFORMATION This text indicates important information or operating instructions. Not observing these instructions could inhibit or impede you from successfully completing the tasks described in this documentation. Symbols Denotes a warning that alerts you to take precautions to avoid injury.
  • Page 9: General Information

    Often intrusive IT software or network processes can interfere with the primary function of the DEWETRON system: to record data. Therefore we recommend strongly against the installation of IT/MIS software and running their proces- ses on any DEWETRON data acquisition system, and cannot guarantee the performance of our systems if they are so configured.
  • Page 10: Printing History

    Printing history Refer to the page bottom for printing version. Copyright © DEWETRON GmbH This document contains information which is protected by copyright. All rights are reserved. Reproduction, adaptation, or translation without prior written permission is prohibited, except as allowed under the copyright laws.
  • Page 11: System Setup

    200 V 1400 V >80 dB @ 50 Hz 70 dB @ 400 Hz Typical CMRR 60 dB @ 1 kHz 48 dB @ 10 kHz Tab. 1: DAQP-HV module specifications DAQP-HV • Technical reference • Printing version 2.3.8 • March 28, 2024...
  • Page 12: General Module Information

    All modules are produced according to ISO 9001 and ISO 14001. Calibration information All DEWETRON modules are calibrated at 25 °C after a warmup time of 30 minutes and meet their specifications when leaving the factory. The time interval for recalibration depends on environmental conditions. Typically, the calibration should be checked once a year.
  • Page 13: Hsi/Daqp Module Configuration

    -5000 series systems are prepared as a standard to work with PAD modules. The easiest way to change the configura- tion is to use the DEWEConfig software, which comes as a standard with the DEWETRON data acquisition system. Detailed information about PAD modules programming for customer applications is available in the DEWE Modules Programmers Reference Manual.
  • Page 14: Connections

    Voltage measurement up to ±600 V must only be carried out with safety banana plug cords. LED state The DAQP-HV modules have a set of 8 LEDs showing the current input range (constant active) and the filter range (flashing). Due to the large number of low pass filters, two LEDs are used to display the current frequency. The left LED indicates the multiplier, the right one shows the exponent with the base of 10.
  • Page 15: Ac Accuracy With Activated Filter

    (% of reading) <0.1 0.01 0.00 0.00 0.02 0.00 0.02 0.03 0.00 0.04 0.05 0.00 0.11 0.01 0.47 0.14 0.73 5.24 0.75 20.34 40.45 40.45 Tab. 2: AC accuracy with activated filter DAQP-HV • Technical reference • Printing version 2.3.8 • March 28, 2024...
  • Page 16: Maintenance And Service

    Disconnect all cables before servicing the unit. Service and repairs We are very sorry that your DEWETRON system is not operating properly. Our team is here to ensure that your DEWE- TRON product is returned to peak performance as quickly as possible.
  • Page 17: Calibration

    Support DEWETRON has a team of people ready to assist you if you have any questions or any technical difficulties regarding the system. For any support contact your local distributor first or DEWETRON directly.
  • Page 18: Certificate Of Conformity

    Certificate of conformity Manufacturer DEWETRON GmbH Address Parkring 4 8074 Grambach, Austria Tel.: +43 316 3070-0 Fax: +43 316 3070-90 Email: sales@dewetron.com http://www.dewetron.com DAQP-HV Name of product Kind of product Signal conditioning module The product meets the regulations of the following EC-directives:...