Page 2
Introduction The 4 x 1 HDMI Seamless Quad PIP Scaler is a high performance, high speed zooming/shrinking system that can be easily configure and control for quad or picture-in-picture video processing. Allowing 4 different input sources to be freely selected and arranged on one single display with supporting output resolution up to 1080p and audio up to 8CH 192kHz for both input and output.
Page 3
Operation Controls and Functions The following sections describe the hardware components of the unit. Front Panel IR Window Accept IR signal from the device’s remote control included in the package. POWER Press this button to power on the device or set it to standby mode. 3.
1. HDMI IN Connect with source equipments such as DVD/Blu-ray players and or PC/NB devices. 2. HDMI OUT Connect with HD TV/monitor for output image display at 1080p. 3. CONTROL Connect to an active network for Telnet control. 4.USB SERVICE ONLY This slot is reserved for factory use only.
Page 5
Press this button to rotate the image 90˚ left and right or 180˚ upside down. 14. Audio 1~4 Press these buttons to select audio from HDMI input source 1~4. Functions only work under Window A to D. The system will force to switch to •...
Page 6
Menu Back Menu Exit Image Adjust Brightness Adjust CH 1 0~100 (50) CH 2 0~100 (50) CH 3 0~100 (50) CH 4 0~100 (50) Value Reset Menu Exit Contrast Adjust CH 1 0~100 (50) CH 2 0~100 (50) CH 3 0~100 (50) CH 4 0~100 (50)
Page 7
Height Ten Height Hundred Position CH1 Hxxx Vxxx Horizontal Unit Horizontal Ten Horizontal Hundred Vertical Unit Vertical Ten Vertical Hundred Image Output On/ Off Priority CH1→4,CH2→3, CH3→2,CH4→1 Window Reset Menu Exit Channel 2 Select Size CH2 Wxxx Hxxx Width Unit Width Ten Width Hundred Height Unit...
Page 8
Menu Exit Channel 3 Select Size CH3 Wxxx Hxxx Width Unit Width Ten Width Hundred Height Unit Height Ten Height Hundred Position CH3 Hxxx Vxxx Horizontal Unit Horizontal Ten Horizontal Hundred Vertical Unit Vertical Ten Vertical Hundred Image Output On/ Off Priority CH1→4,CH2→3, CH3→2,CH4→1...
Page 9
Vertical Ten Vertical Hundred Image Output On/ Off CH1→4,CH2→3, Priority CH3→2,CH4→1 Window Reset Menu Exit Label Select Video 1 VIDEO 1/2/3/4 Video 2 VIDEO 1/2/3/4 Video 3 VIDEO 1/2/3/4 Video 4 VIDEO 1/2/3/4 Menu Exit ON/OFF/OK Favours Store FAV 1 Store FAV 2 Store ON/OFF/OK ON/OFF/OK...
Byte2 XXX 168 255 000~255 XXX 5 255 5 Byte3 000~255 XXX 159 0 254 Byte4 Low 000~255 No/Yes Re-link Exit Static/DHCP IP LINKED/NOT LINKED IP/Mask/Gate Mask XXX.XXX.XXX.XXX Gate XXX.XXX.XXX.XXX XXX.XXX.XXX.XXX Sink HDMI/ DVI Information Model xxxxxxx Native xxxxxxx F/V version Menu Exit Note: BoldItalic fonts and ( ) figures are factory defualt setting figures.
Page 12
OSDDIS 0/1 ENABLE/DISABLE ONSCREEN DISPLAY (0) OFF, (1) ON OSDH 0~20 OSD H OFFSET 0~20 OSDV 0~20 OSD V OFFSET 0~20 OSDTIME 0~50 OSD TIMEOUT 0~50 OSDGAIN 0~10 OSD GAIN VALUE 0~10 SET BRIGHTNESS VALUE FOR CHANNEL BRI 0~4 0~100 (0) All, (1~4) CHANNEL, (0~100) VALUE...
Page 13
IMAGE 1~4 0~1 CHANNEL(S) OUTPUT ON/OFF (1~4) CHANNEL, (0/1) OFF/ON PRI 1~4 1~4 SET CHANNEL PRIORITY (1~4) CHANNEL, (1~4) PRIORITY LABEL 1~4 XXX ASSIGN A VIDEO NAME (1~4) VIDEO, (XXX) ABCEDFGH... SAVE THE CURRENT WINDOW STATE TO FAV. STORE 1~4 (1~4) FAV RECALL 1~12 RECALL A WINDOW STATE...
Page 14
IPADD XXX.XXX. SET IP ADDRESS XXX.XXX (XXX) 0~255 MAADD XXX. SET SUBNET ADDRESS XXX.XXX.XXX (XXX) 0~255 GAADD XXX. SET GATEWAY ADDRESS XXX.XXX.XXX (XXX) 0~255 ETHTIME 0~6 ETHERNET TIMEOUT (0) OFF, (1) 10 MINUTE, (2) 20 MINUTE, (3) 30 MINUTE, (4) 40 MINUTE, (5) 50 MINUTE, (6) 60 MINUTE RELINK RELINK THE UNIT IN 2 SECONDS...
Telnet Control Before attempting to use the telnet control, please ensure that both the Scaler (via the ‘CONTROL’ port) and the PC/Laptop are connected to the active networks. To access the telnet control in Windows 7, click on the ‘Start’ menu and type “cmd” in the Search field then press enterUnder Windows XP go to the ‘Start’...
Page 16
Type “IPCONFIG” To show all IP configurations. To reset the IP, type “IPMODE” to set static IP/DHCP (For a full list of commands, see Section on RS- 232 & Telnet Commands ). Note: All the commands will be not executed unless followed by a carriage return. Commands are case-insensitive.
Page 17
Click on the ‘mage Adjust’ tab to control power, Window Mode and the window setting. Clicking on the ‘Output Resolution’ tab to set the output display resolution.
Page 18
Clicking on the ‘Windows Setup’ tab to set the output display fomat. Note: This function is only available under window E~H Clicking on the ‘OSD Settings’ tab to set the OSD function and position...
Page 19
Clicking on the ‘Window Convert’ tab to set the output display angle. Note: This function is only available under window A~D Clicking on the ‘Chromakey Setup’ tab to set the output display color. Note: This function is only available under window E~H.
Page 20
Clicking on the ‘Ethernet’ tab to reset the IP configuration. The system will ask for a reboot of the device every time when any of the settings is changed. The IP address needed to access the Web GUI control will also need to be changed accordingly on the web address entry bar.
Need help?