Summary of Contents for Lincoln Electric W000380502
Page 1
TABLE ESSENTIAL CUTTING TABLE SAFETY INSTRUCTIONS FOR USE AND MAINTENANCE N° W000380502 - W000375248 - W000375249 8695 8008 EDITION : EN Instructions for use REF : REVISION : A DATE : 09-2022 Original instructions...
Page 2
Thank for the trust you have expressed by purchasing this equipment, which will give you full satisfaction if you follow its instructions for use and maintenance. Its design, component specifications and workmanship comply with applicable European directives. Please refer to the enclosed CE declaration to identify the directives applicable to it.
8695 8008 CONTENTS A - INTRODUCTION .......................... 1 USING THE MANUAL ......................1 MACHINE GUARANTEE ......................1 ASSISTANCE ........................... 1 DESCRIPTION OF PICTOGRAMS ..................1 B - GENERAL SAFETY INSTRUCTIONS ..................2 ELECTRICAL SAFETY ......................2 PERSONAL PROTECTION ..................... 3 FILTRATION OF FUMES AND DUST ..................
Before the filter is used by a new user, make sure that they have read this manual and understood all the explanations provided. For any further information, please feel free to contact the technical departments of LINCOLN ELECTRIC. MACHINE GUARANTEE This machine is guaranteed for 12 months from the date of purchase.
8695 8008/A B - GENERAL SAFETY INSTRUCTIONS ELECTRICAL SAFETY The Essential cutting table does not include any electrical component or fan. However, an external connection is required for the use of this down- draft table. The section below describes the safety rules to apply in such an installation.
8695 8008/A The fan is an essential element of your extraction system. Incorrect operating or inadequate maintenance could make the operating position less safe. The fan must therefore be maintained in perfect condition. your machine has been selected for a specific application. The turbine is characterised by an extraction rate operating point (air speed in the pipes), load loss.
Page 8
8695 8008/A Specific case of chlorine solvents in welding: (used for cleaning or degreasing). The fumes from these solvents can be changed into toxic gases when subjected to arc radiation, including from a distance. Such solvents may therefore not be used in locations where electric arcs occur, if the solvents are not in a sealed enclosure.
Not obstruct the air outlet of the machine Not introduce external elements into the filter (paper, cloths, cigarette butts etc.) Replace the filter medium with new original LINCOLN ELECTRIC medium, which alone can guarantee the filtration characteristics. Replace the hoses if they are pierced.
8695 8008/A C - OVERALL DESCRIPTION For your safety and optimum machine performance, please read this manual carefully before using the equipment. Essential cutting tables are designed for extracting cutting fumes. At the bottom and on the inside, they have drawers with handles for recovering heavy particles.
8695 8008/A D - TECHNICAL DESCRIPTION COMPOSITION OF THE ESSENTIAL CUTTING TABLE The table is made up of : Work surface 1000x500 / 1000x1000 or 2000x1000 mm. Working height 920 mm. Max. load capacity of table: 200 kg. ...
8695 8008/A DIMENSIONS OF THE ESSENTIAL GRINDING TABLE Dimensions of the ESSENTIAL 1000 x 500 cutting table Connection diameter : 250 mm Overall width : 1200 mm Overall depth : 700 mm Overall height : 920 mm Dimensions of the ESSENTIAL 1000 x 1000 grinding table ...
8695 8008/A E - INSTALLING THE ESSENTIAL CUTTING TABLE ASSEMBLY Move the table with a lift truck to its location, then remove the packaging and transport protection material. Connect the table to the air extraction duct using Ø 250, 315 or 450 mm, towards the outdoor environment or a duct system possibly connected to a filtration system.
The performance of operations that may not be carried out or are contrary to the standards and procedures of the “General instructions” section would release LINCOLN ELECTRIC from liability for any damage caused and would void the guarantee if it is still valid.
Page 15
8695 8008/A CONNECTION OPTIONS Description Part number Quantity Box DAMPER BOX ESSENTIAL W000370749 Motorised shutter, diam 250 mm W000380489 Motorised shutter, diam 315 mm W000370744 Motorised shutter, diam 400 mm W000370743 DIGIFILTER 2 CD for 1000 x 500 table EM61000005 DIGIFILTER 4 CD for 1000 x 1000 table EM61000010 DIGIFILTER 8 CD for 2000 x 1000 table...
8695 8008/A PERSONAL NOTES Lincoln Electric France S.A.S. Avenue Franklin Roosevelt 76120 Le Grand Quevilly 76121 Le Grand Quevilly cedex www.lincolnelectriceurope.com ESSENTIAL CUTTING TABLE...