Summary of Contents for Heinzmann PMS Series
Page 1
(axial flow motor) PMS model series Installation instructions Copyright 2017 by Heinzmann GmbH & Co. KG. All rights reserved This publication may not be reproduced or passed on to third parties. Publication No. EA 11 001-e / 10-17 8075...
Page 2
HEINZMANN expressly rejects any implied guarantee pertaining to any marketability or suitability for a special purpose, including in the event that HEINZMANN was notified of such a special purpose or the manual contains a reference to such a special purpose.
Page 3
HEINZMANN shall not provide any guarantee for the design and planning of the overall technical system. This is a matter of the operator, its planners and its specialist engineers. They are also responsible for checking whether the performances of our devices match the intended purpose. The operator is also responsible for a correct initial start-up of the overall system.
Table of contents Table of contents 1 Safety information and relevant signal words and symbols ............ 1 1.1 Safety measures for disc armature motors ............... 2 1.2 Basic safety measures during initial start-up and normal operation ........ 3 1.3 Safety measures for maintenance and servicing............... 4 1.4 Safety measures before starting up again .................
1 Safety information and relevant signal words and symbols 1 Safety information and relevant signal words and symbols This publication provides specific safety information on how to avoid any unavoidable remaining risks when operating a machine. This includes hazards for: ...
1 Safety information and relevant signal words and symbols 1.1 Safety measures for disc armature motors This machine has been designed for reliable utilisation in accordance with the application, conditions and specifications as described in these instructions. Everyone who works on this machine must have read these instructions and the information.
1 Safety information and relevant signal words and symbols 1.2 Basic safety measures during initial start-up and normal operation The motor may only be installed and operated by qualified and authorised personnel! Before switching the motor on for the first time: ...
1 Safety information and relevant signal words and symbols 1.3 Safety measures for maintenance and servicing Before starting maintenance or repair work: Block access to motor operating area or the system for any unauthorised people! Put up an information board that indicates that such work is underway ...
2 Application and function 2 Application and function 2.1 Proper and intended use The disc armature motors of the PMS model series are produced in accordance with DIN EN 60034. They are used solely for the drive or alternator function within their specified limits for stationary purpose as well as mobile application.
2 Application and function 2.3 General technical motor data Degree of Degree of protection IP54 protection (other degrees of protection optionally available on request) Cooling The following types of cooling are available: - Natural cooling - Surface cooling at min. 5 m/s - Water cooling with max.
Page 11
2 Application and function Permissible radial forces at end of shaft All bearings are designed for a service life of approx. 20,000 operating hours. The permissible radial forces are listed in the product catalogue according to motor types. The product catalogue is available from the manufacturer All values are valid for horizontal installation of a motor only without any additional axial forces.
3 Technical drawings, connection diagrams 2.4 Senders and sensors Motor feedback Generally the motors are equipped with a motor feedback function. Apart from the relative position signal from the rotor to the stator this also provides the signal for the current speed. ...
4 Installation 4 Installation Danger through improper installation Risk of injury through heat or flying parts Installation, maintenance and operation to be conducted by skilled personnel only. Before installation make sure that the motor output matches the rating plate for the drive, the motor controller's output voltage and the mains voltage ...
When pulling clutches, belt pulleys and suchlike onto the motor shaft additional excessive axial forces may be generated! These, in turn, will reduce the service life considerably. HEINZMANN shall not be held liable for any such instances!. Therefore, when attaching accessories to the motor shaft, always ensure that the internal thread at the shaft end is used as an installation aid.
In the event of increased radial or axial bearing loads this interval can be significantly reduced. The customer itself is bound to ensure that the permissible operating values are not exceeded. HEINZMANN shall not be held liable.
Temperature sensor not Connect temperature sensor, check connected or evaluation in controller configuration and controller incorrect correct if necessary. Temperature sensor Have temperature sensor replaced defective Motor running noise Bearing damage Consult with motor manufacturer (HEINZMANN)
Publications can be downloaded in PDF format from our internet site: www.heinzmann.com If the required publication is not available there, please contact us by email: info@heinzmann.de or by letter to: HEINZMANN GmbH & Co. KG Technical Editorial Office Am Haselbach 1 D-79677 Schönau, Germany Please enter the following information: ...