Advertisement

Quick Links

Manual
DFV-22
FLOW
Vortex

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FLOW Vortex DFV-22 and is the answer not in the manual?

Questions and answers

Summary of Contents for Duratech FLOW Vortex DFV-22

  • Page 1 Manual DFV-22 FLOW Vortex...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS 1. Technical specifications ..............................3 2. Spare parts list ................................4 3. Packaging contents..............................5 4. Safety instructions ..............................6-7 5. General information ..............................8 5.1 Installation ................................9 5.1.1 Typical installation ..........................9 5.2 Starting the pump and filter system ........................10 5.2.1 Before starting the pump ........................10 5.2.2 Starting the pump ..........................10 6.Operation..................................10 6.1 Filtering ................................
  • Page 3: Technical Specifications

    1. TECHNICAL SPECIFICATIONS CHARACTERISTICS UNIT DFV-22 Filter capacity Minimum particle size µm Minimum flow rate m3/h Maximum flow rate m3/h Connections IN/OUT 50-63 quick fit unions Connection waste 50 quick fit union Maximum pressure Multi cyclones Head loss 1,4m @ 15 m3/h Shipping dimensions (L*W*H) 255*255*426 Warranty...
  • Page 4: Spare Parts List

    2. SPARE PARTS LIST PART NR. PART DESCRIPTION. QTY. ITEM NO. SP-DFV-001 Nut generic SP-DFV-002 Fitting DIA 63 SP-DFV-003 O-Ring 66 SP-DFV-004 Screw SP-DFV-005 O-Ring 180 2 or 7 SP-DFV-006 O-Ring 63 SP-DFV-007 Fitting DIA50 2 or 7 Figure 2...
  • Page 5: Packaging Contents

    3. PACKAGING CONTENTS Size 63 (2x) Size 50 (3x) x1 Quick Start Guide...
  • Page 6: Safety Instructions

    3. SAFETY INSTRUCTIONS READ, UNDERSTAND AND FOLLOW ALL SAFETY AND OPERATION INSTRUCTIONS! Failure to follow safety and operation instructions can result in severe personal injury or death. This is the safety-alert symbol. When you see this symbol on your equipment or in this manual, look for one of the following signal words and be alert to the potential for personal injury or death.
  • Page 7 TO AVOID COMPONENT SEPARATION - Follow all safety and operation instructions. - Do not operate the water filtration system if a system component is assembled improperly, damaged, missing, or not a genuine component. - Before performing maintenance on the water filtration system, verify all system and pump controls are in OFF position.
  • Page 8: General Information

    4. GENERAL INFORMATION The ‘FLOW Vortex pre-filter’ combines superior water filtration with ease of operation and totally corrosion-resistant construction. With filtration ratings to 32000 liters/hour they are designed for continuous or intermittent operation. For installation above or below the pool water line, for fresh or salt water swimming pools or spa’s.
  • Page 9: Installation

    4.1. Installation This product should be installed and serviced only by a qualified pool professional. WARNING - The filter system should be installed in a stable manner in the water circuit and should be supported if necessary. Select a well drained and vented .. area, one that does not flood when it rains. Position the filter so that the piping connections are convenient and accesible for operation, service, maintenance and winterizing.
  • Page 10: Starting The Pump And Filter System

    Verify that top and sediment bowl are properly secured Verify that the filter ring is in the CLOSED position, and no filter components are missing, damaged or not genuine DuraTech components. - Close filter drain. - Open all system valves to allow water from the pool to the filtration system and from the filter to return to the pool.
  • Page 11: Maintaining Your Filter

    5.2 Maintaining your filter This product should be installed and serviced only by a qualified pool professional. WARNING 5.2.1 Checkup debris in sediment bowl When the collected debris reaches the maximum level indication on the sediment bowl, the dirt should be purged out of the sediment bowl by opening the valve in the drain pipe.
  • Page 12: Filter Disassembly Instructions

    5.2.2 Filter Disassembly Instructions 1: Switch off the water circulation pump 2: Close the valve before and after the filter 3: Open the purge valve to drain the water in the filter 4: Loosen the unions 3: Detach the filter from the water circuit 4: Loosen the ring by turning it in the direction of the arrow for opening the filter 5: Pull the sediment bowl from the top housing...
  • Page 13 6: Take out the baffle CLEANING INSTRUCTIONS: - After disassembly, the filter components can be cleaned by rinsing the filter with water...
  • Page 14: Re-Assembly Instructions

    WARNING 5.2.3 Re-assembly instructions a. reassemble the FLOW Vortex in reverse direction of the filter disassembly Figure 6...
  • Page 15: Winterizing Filter

    6. WINTERIZING FILTER This product should be installed and serviced only by a qualified pool professional. WARNING In areas where subfreezing temperatures can be expected, the filter should be drained to protect the filter from damage. 7. PROBLEM SOLVING LIST 7.1 Low Water Flow a.
  • Page 16 HEAD LOSS Measurement Typical Head Loss 0,35 0,25 0,15 0,05 Volume Flow Rate - m³/h Flow (M3/h) VORTEX...
  • Page 18 Propulsion Systems BV Dooren 72 1785 Merchtem, Belgium Tel +32 2 461 02 53 Fax +32 2 706 59 60 www.duratech.be info@propulsionsystems.be DURAFLOW We reserve the rights to change all or part of the contents of this document without prior notice.