Download Print this page

Air King M-40 Series Installation And Service Manual page 4

Advertisement

READ AND SAVE THIS MANUAL COMPLETELY AND COMPLY AS DIRECTED. THIS MANUAL CONTAINS
PRECAUTIONARY STATEMENTS RELATING TO WORKER SAFETY. WORKERS HANDLING EQUIPMENT OR
SYSTEMS SHOULD BE INSTRUCTED TO CONDUCT THEMSELVES IN A SAFE MANNER. ALL THE POTENTIAL
HAZARD OF DUST AND MIST CONTROL SYSTEMS AND EQUIPMENT ARE IMPOSSIBLE TO LIST. THEREFORE,
OBTAIN THE SERVICES OF A PROFESSIONAL INSTALLER. A FIRE PROTECTION EXPERT SHOULD BE
OBTAINED IN THE EVENT THE PRODUCT IS INTENDED FOR USES WHICH PRESENT A POTENTIAL RISK OF
FIRE OR FIRE PROPOGATION. REFER TO APPROPRIATE AUTHORITIES AND DISCUSS YOUR INTENDED USE
If your new Air King units were shipped in by truck you should inspect the carton for damages or possible shortages. If
there are any signs of possible shipping damages, unpack the units and make a note of the shortage or damage on the
freight bill before signing it. If the carton is opened at a later time and there is damage to the unit, you should file a
concealed damage claim with the delivery carrier. They are responsible for any damages in shipment or shortages that
Installation instructions should be furnished by your supplier. All installations must meet all electrical or mechanical
building codes that may apply in your particular area. If there are no local requirements, you should follow the National
All chains, hooks, bolts or other items used in the installation must be at least strong enough to support FOUR times the
There are many different ways to install your units. The most common method of
installing the units is to support them from the ceiling structure with four chains. If
you are going to use this method, you should drill 4 holes down through the top of the
unit approximately 8" in from each end and ¾" in from each side of the unit. Use at
least 7/16" eyebolts with nuts and washers both inside and outside of the unit. The top end of the chains must be secured
to the ceiling structure in a safe and acceptable manner. Be sure your unit is connected to the proper voltage and is
AIR KING products are designed to improve your environment. M-40 series collects dust, smoke, oil mist, oil smoke, and
other atmospheric pollutants in industrial plants, shops, schools, and factories with high efficiency, 2 or 3 stage filtration.
It is a complete air filter packaged unit that can be installed easily and used as a free hanging air filter unit to clean the
The Air King M-40's consists of a 4" pleated prefilter that traps dust and larger particles. The second stage, micro-glass
multi-pocket bag filter has 98% arrestance and either 65 or 95% efficiency (depending on the application) on the
atmospheric dust spot test, removing smoke and other submicron size particles from the air. Changing out the filters is
easy as it requires no tools. The 4" prefilter pulls from the unit and can be replaced. The main filter is located directly
behind the 4" prefilter and pulls out also. For light odors, there is an optional 2" 50% bypass charcoal filter available.
WITH YOUR LOCAL AIR KING DISTRIBUTOR.
were actually shipped.
Installing Your New AIR KING Units
weight of each unit. Unit weights are as follows:
Air King M-40H
440 lbs
Air King M-40V
390 lbs
Air King M-40V3/H3
515 lbs
Air King M-40HD
660 lbs
Air King M-40HT
920 lbs
protected by correct size fuses or breakers.
ambient pollutants, smoke and haze.
SAFETY
Initial Inspection
requirements.
4

Advertisement

loading

Related Products for Air King M-40 Series

This manual is also suitable for:

M-40hM-40vM-40v3M-40h3M-40hdM-40ht